Prostate Histopathology: Learning Tissue Component Histograms for Cancer Detection and Classification
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Radical prostatectomy is performed on approximately 40% of men with organ-confined prostate cancer. Pathologic information obtained from the prostatectomy specimen provides important prognostic information and guides recommendations for adjuvant treatment. The current pathology protocol in most centers involves primarily qualitative assessment. In this paper, we describe and evaluate our system for automatic prostate cancer detection and grading on hematoxylin & eosin-stained tissue images. Our approach is intended to address the dual challenges of large data size and the need for high-level tissue information about the locations and grades of tumors. Our system uses two stages of AdaBoost-based classification. The first provides high-level tissue component labeling of a superpixel image partitioning. The second uses the tissue component labeling to provide a classification of cancer versus noncancer, and low-grade versus high-grade cancer. We evaluated our system using 991 sub-images extracted from digital pathology images of 50 whole-mount tissue sections from 15 prostatectomy patients. We measured accuracies of 90% and 85% for the cancer versus noncancer and high-grade versus low-grade classification tasks, respectively. This system represents a first step toward automated cancer quantification on prostate digital histopathology imaging, which could pave the way for more accurately informed postprostatectomy patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
Self-citationTop 10 algorithms in data mining
Wu, X., Kumar, V., Ross Quinlan, J., Ghosh, J., Yang, Q., Motoda, H., McLachlan, G. J., Ng, A., Liu, B., Yu, P. S., et al. (2008) · Knowledge and Information Systems · doi:10.1007/s10115-007-0114-2 · Cited by 5,667
An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Graph Cuts and Efficient N-D Image Segmentation
Boykov, Y., & Funka-Lea, G. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7934-5 · Cited by 1,910
Learning a classification model for segmentation
Ren, & Malik (2003) · Proceedings Ninth IEEE International Conference on Computer Vision · doi:10.1109/iccv.2003.1238308 · Cited by 1,765
Cited by
A new era: artificial intelligence and machine learning in prostate cancer
Goldenberg, S. L., Nir, G., & Salcudean, S. E. (2019) · Nature Reviews Urology · doi:10.1038/s41585-019-0193-3 · Cited by 511
Xu, Y., Jia, Z., Wang, L.-B., Ai, Y., Zhang, F., Lai, M., & Chang, E. I.-C. (2017) · BMC Bioinformatics · doi:10.1186/s12859-017-1685-x · Cited by 416
Epstein, J. I., Amin, M. B., Fine, S. W., Algaba, F., Aron, M., Baydar, D. E., Beltran, A. L., Brimo, F., Cheville, J. C., Colecchia, M., et al. (2021) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2020-0015-ra · Cited by 280
Nir, G., Hor, S., Karimi, D., Fazli, L., Skinnider, B. F., Tavassoli, P., Turbin, D., Villamil, C. F., Wang, G., Wilson, R. S., et al. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.09.005 · Cited by 178
Fundamental developments in infrared spectroscopic imaging for biomedical applications
Pilling, M., & Gardner, P. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00846h · Cited by 165
Large Margin Local Estimate With Applications to Medical Image Classification
Song, Y., Cai, W., Huang, H., Zhou, Y., Feng, D. D., Wang, Y., Fulham, M. J., & Chen, M. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2393954 · Cited by 87
“The combination of weak classifiers is normally based on a predefined weighting scheme, such as the majority voting or averaging of probabilities in bagging [5], [14], [15], [22], [47], [48], or choosing the best performing weak classifier at each training iteration with errorbased weight computation in boosting [21],…”
BackgroundAutomatic Recognition of Fetal Facial Standard Plane in Ultrasound Image via Fisher Vector
Lei, B., Tan, E.-L., Chen, S., Zhuo, L., Li, S., Ni, D., & Wang, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0121838 · Cited by 43
Qi, X., Karagoz, K., Ren, J., Foran, D. J., & Gatza, M. (2018) · Medical Imaging 2018: Imaging Informatics for Healthcare, Research, and Applications · doi:10.1117/12.2293193 · Cited by 11
Automatic placental maturity grading via hybrid learning
Lei, B., Tan, E.-L., Chen, S., Li, W., Ni, D., Yao, Y., & Wang, T. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.033 · Cited by 5
Metadata
- Authors
- Gorelick, L., Veksler, O., Gaed, M., Gomez, J. A., Moussa, M., Bauman, G., Fenster, A., & Ward, A. D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-10
- Volume
- 32
- Issue
- 10
- Pages
- 1804-1818
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W1993760967
- Cited by
- 119
- References
- 7
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.