Visual SLAM for Handheld Monocular Endoscope
The DOI matches its Crossref record; 34 of the 37 references it cites were found in a registry or an index.
Abstract
Simultaneous localization and mapping (SLAM) methods provide real-time estimation of 3-D models from the sole input of a handheld camera, routinely in mobile robotics scenarios. Medical endoscopic sequences mimic a robotic scenario in which a handheld camera (monocular endoscope) moves along an unknown trajectory while observing an unknown cavity. However, the feasibility and accuracy of SLAM methods have not been extensively validated with human in vivo image sequences. In this work, we propose a monocular visual SLAM algorithm tailored to deal with medical image sequences in order to provide an up-to-scale 3-D map of the observed cavity and the endoscope trajectory at frame rate. The algorithm is validated over synthetic data and human in vivo sequences corresponding to 15 laparoscopic hernioplasties where accurate ground-truth distances are available. It can be concluded that the proposed procedure is: 1) noninvasive, because only a standard monocular endoscope and a surgical tool are used; 2) convenient, because only a hand-controlled exploratory motion is needed; 3) fast, because the algorithm provides the 3-D map and the trajectory in real time; 4) accurate, because it has been validated with respect to ground-truth; and 5) robust to inter-patient variability, because it has performed successfully over the validation sequences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent results in non-rigid SfM such as [91, 96] are less restrictive but only work in small scenarios.”
From Past, Present, and Future of Simultaneous Localization and Mapping: Toward the Robust-Perception Age (2016) · cites this paper as [96]
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Parallel Tracking and Mapping for Small AR Workspaces
Klein, G., & Murray, D. (2007) · 2007 6th IEEE and ACM International Symposium on Mixed and Augmented Reality · doi:10.1109/ismar.2007.4538852 · Cited by 4,346
Flexible camera calibration by viewing a plane from unknown orientations
Zhang, Z. (1999) · Proceedings of the Seventh IEEE International Conference on Computer Vision · doi:10.1109/iccv.1999.791289 · Cited by 2,610
Real-time simultaneous localisation and mapping with a single camera
Davison (2003) · Proceedings Ninth IEEE International Conference on Computer Vision · doi:10.1109/iccv.2003.1238654 · Cited by 1,733
Fusing points and lines for high performance tracking
Rosten, E., & Drummond, T. (2005) · Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1 · doi:10.1109/iccv.2005.104 · Cited by 1,119
Introduction to modern photogrammetry
Mikhail, E. M., Bethel, J., & McGlone, J. C. (2001) · Cited by 1,019
Inverse Depth Parametrization for Monocular SLAM
Civera, J., Davison, A. J., & Montiel, J. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2003276 · Cited by 779
Self-citationData association in stochastic mapping using the joint compatibility test
Neira, J., & Tardos, J. D. (2001) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.976019 · Cited by 772
Augmented reality in laparoscopic surgical oncology
Nicolau, S., Soler, L., Mutter, D., & Marescaux, J. (2011) · Surgical Oncology · doi:10.1016/j.suronc.2011.07.002 · Cited by 367
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
Maier-Hein, L., Mountney, P., Bartoli, A., Elhawary, H., Elson, D., Groch, A., Kolb, A., Rodrigues, M., Sorger, J., Speidel, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.04.003 · Cited by 280
Research works printed but not linked: 2
- gil, 2011, Augmented reality and 3-D measurement for monocular laparoscopic abdominal wall hernia repair, 46th Cong Eur Soc Surg Res, 98, 1
- grasa, 2009, EKF monocular SLAM 3-D modeling, measuring and augmented reality from endoscope image sequences, Proc 5th Workshop AMI-ARCS 12th Int Conf MICCAI, 102
Cited by
Past, Present, and Future of Simultaneous Localization and Mapping: Toward the Robust-Perception Age
Cadena, C., Carlone, L., Carrillo, H., Latif, Y., Scaramuzza, D., Neira, J., Reid, I., & Leonard, J. J. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2624754 · Cited by 3,596
“Recent results in nonrigid SfM such as [92], [97] are less restrictive but only work in small scenarios.”
Past, present, and future of simultaneous localization and mapping: Toward the robust-perception age
Cadena, C., Carlone, L., Carrillo, H., Latif, Y., Scaramuzza, D., Neira, J., Reid, I. D., & Leonard, J. J. (2016) · Zurich Open Repository and Archive (University of Zurich) · doi:10.5167/uzh-138892 · Cited by 3,048
The status of augmented reality in laparoscopic surgery as of 2016
Bernhardt, S., Nicolau, S. A., Soler, L., & Doignon, C. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.01.007 · Cited by 314
Ozyoruk, K. B., Gokceler, G. I., Bobrow, T. L., Coskun, G., Incetan, K., Almalioglu, Y., Mahmood, F., Curto, E., Perdigoto, L., Oliveira, M., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102058 · Cited by 270
Unsupervised Reverse Domain Adaptation for Synthetic Medical Images via Adversarial Training
Mahmood, F., Chen, R., & Durr, N. J. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2842767 · Cited by 257
“in robotic and laparoscopic surgery [42]–[45].”
Application of artificial intelligence in surgery
Zhou, X.-Y., Guo, Y., Shen, M., & Yang, G.-Z. (2020) · Frontiers of Medicine · doi:10.1007/s11684-020-0770-0 · Cited by 181
Recasens, D., Lamarca, J., Facil, J. M., Montiel, J. M. M., & Civera, J. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3095528 · Cited by 175
Self-citationDense Depth Estimation in Monocular Endoscopy With Self-Supervised Learning Methods
Liu, X., Sinha, A., Ishii, M., Hager, G. D., Reiter, A., Taylor, R. H., & Unberath, M. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2950936 · Cited by 174
Endoscope image mosaic based on pyramid ORB
Zhang, Z., Wang, L., Zheng, W., Yin, L., Hu, R., & Yang, B. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103261 · Cited by 171
Recent Developments and Future Challenges in Medical Mixed Reality
Chen, L., Day, T. W., Tang, W. J., & John, N. W. (2017) · Proceedings - International Symposium on Mixed and Augmented Reality, ISMAR · doi:10.1109/ismar.2017.29 · Cited by 191
Chen, L., Tang, W. J., John, N. W., Wan, T. R., & Zhang, J. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.02.006 · Cited by 175
Live Tracking and Dense Reconstruction for Handheld Monocular Endoscopy
Mahmoud, N., Collins, T., Hostettler, A., Soler, L., Doignon, C., & Montiel, J. M. M. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2856109 · Cited by 164
Self-citationORBSLAM-Based Endoscope Tracking and 3D Reconstruction
Mahmoud, N., Cirauqui, I., Hostettler, A., Doignon, C., Soler, L., Marescaux, J., & Montiel, J. M. M. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-54057-3_7 · Cited by 139
Self-citationDefSLAM: Tracking and Mapping of Deforming Scenes From Monocular Sequences
Lamarca, J., Parashar, S., Bartoli, A., & Montiel, J. M. M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2020.3020739 · Cited by 125
Self-citationBergen, T., & Wittenberg, T. C. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2384134 · Cited by 115
The Future of Endoscopic Navigation: A Review of Advanced Endoscopic Vision Technology
Fu, Z., Jin, Z., Zhang, C., He, Z., Zha, Z., Hu, C., Gan, T., Yan, Q., Wang, P., & Ye, X. (2021) · IEEE Access · doi:10.1109/access.2021.3065104 · Cited by 97
Lin, B., Sun, Y., Qian, X., Goldgof, D. B., Gitlin, R. D., & You, Y. (2015) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1661 · Cited by 87
Simultaneous Localization And Mapping: Present, Future, and the Robust-Perception Age.Preprint
Cadena, C., Carlone, L., Carrillo, H., Latif, Y., Scaramuzza, D., Neira, J., Reid, I. D., & Leonard, J. J. (2016) · arXiv (Cornell University) · Cited by 90
On-patient see-through augmented reality based on visual SLAM
Mahmoud, N., Grasa, Ó. G., Nicolau, S., Doignon, C., Soler, L., Marescaux, J., & Montiel, J. M. M. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1444-x · Cited by 83
Self-citationRNNSLAM: Reconstructing the 3D colon to visualize missing regions during a colonoscopy
Ma, R., Wang, R., Zhang, Y., Pizer, S. M., McGill, S., Rosenman, J. G., & Frahm, J. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102100 · Cited by 99
SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction
Edwards, P., Psychogyios, D., Speidel, S., Maier‐Hein, L., & Stoyanov, D. V. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102302 · Cited by 87
Whole Stomach 3D Reconstruction and Frame Localization From Monocular Endoscope Video
Widya, A. R., Monno, Y., Okutomi, M., Suzuki, S., Gotoda, T., & Miki, K. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2946802 · Cited by 66
Xu, L., Zhang, H., Wang, J., Li, A., Song, S., Ren, H., Qi, L., Gu, J. J., & Meng, M. Q. ‐. (2022) · Information Fusion · doi:10.1016/j.inffus.2022.11.015 · Cited by 62
Real-Time Dense Reconstruction of Tissue Surface From Stereo Optical Video
Zhou, H., & Jayender, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2927436 · Cited by 79
A non-rigid map fusion-based direct SLAM method for endoscopic capsule robots
Turan, M., Almalioglu, Y., Araujo, H., Konukoğlu, E., & Sitti, M. (2017) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-017-0036-4 · Cited by 83
Cui, B., Islam, M., Bai, L., Wang, A., & Ren, H. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-72089-5_20 · Cited by 117
Tracking and mapping in medical computer vision: A review
Schmidt, A., Mohareri, O., DiMaio, S., Yip, M. C., & Salcudean, S. E. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103131 · Cited by 100
Deep Learning for Visual SLAM in Transportation Robotics: A review
Duan, C., Junginger, S., Huang, J., Jin, K., & Thurow, K. (2019) · Transportation Safety and Environment · doi:10.1093/tse/tdz019 · Cited by 63
3D reconstruction of cystoscopy videos for comprehensive bladder records
Lurie, K. L., Angst, R., Zlatev, D. V., Liao, J. C., & Bowden, A. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002106 · Cited by 65
Self-Supervised Lightweight Depth Estimation in Endoscopy Combining CNN and Transformer
Yang, Z., Pan, J., Dai, J. P., Sun, Z., & Xiao, Y. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3352390 · Cited by 77
Azagury, D. E., Dua, M. M., Barrese, J. C., Henderson, J. M., Buchs, N. C., Ris, F., Cloyd, J. M., Martinie, J. B., Razzaque, S., Nicolau, S., et al. (2015) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2015.10.001 · Cited by 65
Self-supervised Learning for Dense Depth Estimation in Monocular Endoscopy
Liu, X., Sinha, A., Unberath, M., Ishii, M., Hager, G. D., Taylor, R. H., & Reiter, A. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01201-4_15 · Cited by 61
Extremely Dense Point Correspondences Using a Learned Feature Descriptor
Liu, X., Zheng, Y., Killeen, B. D., Ishii, M., Hager, G. D., Taylor, R. H., & Unberath, M. (2020) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr42600.2020.00490 · Cited by 66
Fast Direct Stereo Visual SLAM
Mo, J., Islam, M. J., & Sattar, J. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3133860 · Cited by 53
SAGE: SLAM with Appearance and Geometry Prior for Endoscopy
Liu, X., Li, Z., Ishii, M., Hager, G. D., Taylor, R. H., & Unberath, M. (2022) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra46639.2022.9812257 · Cited by 68
A non-rigid map fusion-based direct SLAM method for endoscopic capsule robots
Turan, M., Almalıoğlu, Y., Araújo, H. J., Ender Konukoglu, A., & Sitti, M. (2017) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000236254 · Cited by 44
Self-supervised Generative Adversarial Network for Depth Estimation in Laparoscopic Images
Huang, B., Zheng, J.-Q., Nguyen, A., Tuch, D. S., Vyas, K. N., Giannarou, S., & Elson, D. S. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87202-1_22 · Cited by 53
Wang, K., Chen, Y., Wang, Y., Li, S., Wang, Y., Dou, Q., Yang, X., & Shen, W. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-72089-5_21 · Cited by 51
Castellani, U., & Bartoli, A. (2012) · Springer eBooks · doi:10.1007/978-1-4471-4063-4_6 · Cited by 51
Qiu, L., & Ren, H. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00295 · Cited by 41
3D Reconstruction of Whole Stomach from Endoscope Video Using Structure-from-Motion
Widya, A. R., Monno, Y., Imahori, K., Okutomi, M., Suzuki, S., Gotoda, T., & Miki, K. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857964 · Cited by 41
Optical flow-based structure-from-motion for the reconstruction of epithelial surfaces
Phan, T.-B., Trinh, D. H., Wolf, D., & Daul, C. (2020) · Pattern Recognition · doi:10.1016/j.patcog.2020.107391 · Cited by 47
SLAM Endoscopy enhanced by adversarial depth predictionPreprint
Chen, R. J., Bobrow, T. L., Athey, T. L., Mahmood, F., & Durr, N. J. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1907.00283 · Cited by 63
Dynamic RGB-D SLAM Based on Static Probability and Observation Number
Liu, Y., Wu, Y., & Pan, W. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3089228 · Cited by 34
Shape Acquisition and Registration for 3D Endoscope Based on Grid Pattern Projection
Furukawa, R., Morinaga, H., Sanomura, Y., Tanaka, S., Yoshida, S., & Kawasaki, H. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-46466-4_24 · Cited by 32
3D reconstruction from endoscopy images: A survey
Yang, Z., Dai, J. P., & Pan, J. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108546 · Cited by 44
Real‐time geometry‐aware augmented reality in minimally invasive surgery
Chen, L. F., Tang, W. J., & John, N. W. (2017) · Healthcare Technology Letters · doi:10.1049/htl.2017.0068 · Cited by 30
SLAM based Quasi Dense Reconstruction For Minimally Invasive Surgery ScenesPreprint
Mahmoud, N., Hostettler, A., Collins, T., Soler, L., Doignon, C., & Montiel, J. M. M. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1705.09107 · Cited by 30
Self-citationStomach 3D Reconstruction Using Virtual Chromoendoscopic Images
Widya, A. R., Monno, Y., Okutomi, M., Suzuki, S., Gotoda, T., & Miki, K. (2021) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2021.3062226 · Cited by 25
Turan, M., Almalıoğlu, Y., Örnek, E. P., Araújo, H. J., Yanik, M. F., & Sitti, M. (2018) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2018.8594485 · Cited by 28
Marmol, A., Peynot, T., Eriksson, A. P., Jaiprakash, A. T., Roberts, J. M., & Crawford, R. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2714150 · Cited by 22
Péntek, Q., Hein, S., Miernik, A. J., & Reiterer, A. (2017) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2016-0185 · Cited by 20
Lin, S., Miao, A. J., Lu, J., Yu, S., Chiu, Z.-Y., Richter, F., & Yip, M. C. (2023) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48891.2023.10160746 · Cited by 34
2-DOF auto-calibration for a 3D endoscope system based on active stereo
Furukawa, R., Masutani, R., Miyazaki, D., Baba, M., Hiura, S., Visentini-Scarzanella, M., Morinaga, H., Kawasaki, H., & Sagawa, R. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320233 · Cited by 18
Endoscopic image feature matching via motion consensus and global bilateral regression
Chu, Y., Li, H., Li, X., Ding, Y., Yang, X., Ai, D., Chen, X., Wang, Y., & Yang, J. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105370 · Cited by 21
Intraoperative on-the-fly organ-mosaicking for laparoscopic surgery
Reichard, D., Bodenstedt, S., Suwelack, S., Mayer, B. F. B., Preukschas, A. A., Wagner, M., Kenngott, H., Müller-Stich, B. P., Dillmann, R., & Speidel, S. (2015) · Journal of medical imaging · doi:10.1117/1.jmi.2.4.045001 · Cited by 17
Furukawa, R., Aoyama, M., Hiura, S., Aoki, H., Kominami, Y., Sanomura, Y., Yoshida, S., Tanaka, S., Sagawa, R., & Kawasaki, H. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944745 · Cited by 17
3D endoscope system using DOE projector
Furukawa, R., Sanomura, Y., Tanaka, S., Yoshida, S., Sagawa, R., Visentini-Scarzanella, M., & Kawasaki, H. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591140 · Cited by 17
Furukawa, R., Nagamatsu, G., Oka, S., Kotachi, T., Okamoto, Y., Tanaka, S., & Kawasaki, H. (2019) · Healthcare Technology Letters · doi:10.1049/htl.2019.0070 · Cited by 17
Endoscope navigation with SLAM-based registration to computed tomography for transoral surgery
Qiu, L., & Ren, H. (2020) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-020-00127-2 · Cited by 16
Feature-based Visual Odometry for Bronchoscopy: A Dataset and Benchmark
Deng, J., Li, P., Dhaliwal, K., Lu, C. X., & Khadem, M. (2023) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros55552.2023.10342034 · Cited by 14
Huang, Y., Cui, B., Bai, L., Chen, Z., Wu, J., Li, Z., Liu, H., & Ren, H. (2025) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra55743.2025.11128637 · Cited by 19
Surgical instruments hyalinization: Occlusion removal in minimally invasive endoscopic surgery
Xie, D., Chen, W., Zhao, J., Song, X., Wang, K., Xia, W., Liu, H., Chang, F., Li, C., & Duan, X. (2023) · Biomimetic Intelligence and Robotics · doi:10.1016/j.birob.2023.100105 · Cited by 15
A review on monocular tracking and mapping: from model-based to data-driven methods
Gadipudi, N., Elamvazuthi, I., Izhar, L. I., Tiwari, L., Hebbalaguppe, R., Lu, C., & Doss, A. S. A. (2022) · The Visual Computer · doi:10.1007/s00371-022-02702-z · Cited by 17
Word Ordering and Document Adjacency for Large Loop Closure Detection in 2-D Laser Maps
Deray, J., Solà, J., & Andrade‐Cetto, J. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2657796 · Cited by 15
Multi-level feature aggregation network for instrument identification of endoscopic images
Chu, Y., Yang, X., Li, H., Ai, D., Ding, Y., Fan, J., Song, H., & Yang, J. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab8dda · Cited by 13
Visual SLAM for bronchoscope tracking and bronchus reconstruction in bronchoscopic navigation
Wang, C., Oda, M., Hayashi, Y., Kitasaka, T., Honma, H., Takabatake, H., Mori, M., Natori, H., & Mori, K. (2019) · SPIE Medical Imaging: Image-Guided Procedures, Robotic Interventions, and Modeling · doi:10.1117/12.2512766 · Cited by 12
Furukawa, R., Mizomori, M., Hiura, S., Oka, S., Tanaka, S., & Kawasaki, H. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01201-4_16 · Cited by 12
Visual Robot Relocalization Based on Multi-Task CNN and Image-Similarity Strategy
Xie, T., Wang, K., Li, R., & Tang, X. (2020) · Sensors · doi:10.3390/s20236943 · Cited by 11
Monocular endoscope 6-DoF tracking with constrained evolutionary stochastic filtering
Luo, X., Xie, L., Zeng, H., Wang, X., & Li, S. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102928 · Cited by 13
Fu, Z., Jin, Z., Zhang, C., Dai, Y., Gao, X., Wang, Z., Li, L., Ding, G., Hu, H., Wang, P., et al. (2021) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2274 · Cited by 14
ReSLAM: Reusable SLAM with heterogeneous cameras
Romero-Ramírez, F. J., Muñoz‐Salinas, R., Marín-Jiménez, M. J., Carmona-Poyato, A., & Medina-Carnicer, R. (2023) · Neurocomputing · doi:10.1016/j.neucom.2023.126940 · Cited by 10
Visual SLAM Based on Object Detection Network: A Review
Peng, J., Chen, D., Yang, Q. X., Yang, C., Xu, Y. D., & Qin, Y. (2023) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2023.041898 · Cited by 12
Hierarchical Structure from Motion from Endoscopic Video
Mills, S. J., Szymanski, L., & Johnson, R. (2014) · International Conference on Image and Vision Computing New Zealand (IVCNZ) · doi:10.1145/2683405.2683411 · Cited by 10
Turan, M., Abdullah, A., Jamiruddin, R., Araújo, H. J., Konukoğlu, E., & Sitti, M. (2017) · Cited by 9
Jonmohamadi, Y., Ali, S., Liu, F., Roberts, J. M., Crawford, R., Carneiro, G., & Pandey, A. K. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87196-3_36 · Cited by 11
Zhang, X., Ji, X., Wang, J., Fan, Y., & Tao, C. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-023-00263-1 · Cited by 11
V²-SfMLearner: Learning Monocular Depth and Ego-Motion for Multimodal Wireless Capsule Endoscopy
Bai, L., Cui, B., Wang, L., Li, Y., Yao, S., Yuan, S., Wu, Y., Zhang, Y., Meng, M. Q. ‐., Li, Z., et al. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3530791 · Cited by 14
Cost-Efficient Video Synthesis and Evaluation for Development of Virtual 3D Endoscopy
Zhou, Y., Eimen, R. L., Seibel, E. J., & Bowden, A. K. (2021) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2021.3132193 · Cited by 9
Live Image-Based Neurosurgical Guidance and Roadmap Generation Using Unsupervised Embedding
Sarwin, G., Carretta, A., Staartjes, V. E., Zoli, M., Mazzatenta, D., Regli, L., Serra, C., & Konukoğlu, E. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-34048-2_9 · Cited by 10
Augmented Reality for Depth Cues in Monocular Minimally Invasive SurgeryPreprint
Chen, L., Tang, W. J., John, N. W., Wan, T. R., & Zhang, J. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1703.01243 · Cited by 9
Magnetic-Visual Sensor Fusion based Medical SLAM for Endoscopic Capsule RobotPreprint
Turan, M., Almalıoğlu, Y., Gilbert, H. B., Araújo, H. J., Ender Konukoglu, A., & Sitti, M. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1705.06196 · Cited by 9
Johnson, R., Szymanski, L., & Mills, S. J. (2014) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2014.08.004 · Cited by 8
A monocular SLAM system based on SIFT features for gastroscope tracking
Wang, Y., Zhao, L., Gong, L., Chen, X., & Zuo, S. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02739-1 · Cited by 8
Speers, A., Ma, B., Jarnagin, W. R., Himidan, S. A., Simpson, A. L., & Wildes, R. P. (2018) · Healthcare Technology Letters · doi:10.1049/htl.2018.5071 · Cited by 8
A novel SLAM method for laparoscopic scene reconstruction with feature patch tracking
Wei, G., Feng, G., Li, H., Chen, T., Shi, W., & Jiang, Z. (2020) · International Conference on Virtual Reality and Visualization · doi:10.1109/icvrv51359.2020.00071 · Cited by 7
Castellani, U., & Bartoli, A. (2020) · Springer eBooks · doi:10.1007/978-3-030-44070-1_8 · Cited by 17
Shi, Y., Li, J., Yang, Y., Li, Z., Fukuda, T., & Shi, C. (2025) · Advanced Robotics Research · doi:10.1002/adrr.202500074 · Cited by 6
Improved ORB-SLAM Based 3D Dense Reconstruction for Monocular Endoscopic Image
Chen, W., Liao, X., Sun, Y., & Wang, Q. (2020) · International Conference on Virtual Reality and Visualization · doi:10.1109/icvrv51359.2020.00030 · Cited by 6
A Comparison Study on Replacing Stereo Disparity with LiDAR in Visual Odometry Methods
Golban, C., Cobarzan, P., & Nedevschi, S. (2020) · IEEE International Conference on Intelligent Computer Communication and Processing (ICCP) · doi:10.1109/iccp51029.2020.9266228 · Cited by 6
Monocular endoscopy images depth estimation with multi-scale residual fusion
Liu, S., Fan, J.-F., Yang, Y., Xiao, D., Ai, D.-N., Song, H., Wang, Y.-T., & Yang, J. (2023) · Comput. Biol. Medicine · doi:10.1016/j.compbiomed.2023.107850 · Cited by 6
Learnable patchmatch and self-teaching for multi-frame depth estimation in monocular endoscopy
Shao, S., Pei, Z., Chen, W., Wu, X., & Liu, Z. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.112463 · Cited by 9
Bernal, E., Casado, S., Grasa, Ó. G., Montiel, J. M. M., & Gil, I. (2014) · Surgical Endoscopy · doi:10.1007/s00464-014-3632-5 · Cited by 5
Self-citationLaparoscopic Scene Reconstruction Based on Multiscale Feature Patch Tracking Method
Wei, G., Yang, H., Shi, W., Jiang, Z., Chen, T., & Wang, Y. (2021) · International Conference on Electronic Information Engineering and Computer Science (EIECS) · doi:10.1109/eiecs53707.2021.9588016 · Cited by 5
Ozyoruk, K. B., Gokceler, G. I., Coskun, G., İncetan, K., Almalıoğlu, Y., Mahmood, F., Curto, E., Perdigoto, L., Oliveira, M., Sahin, H., et al. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2006.16670 · Cited by 13
Tukra, S., Lidströmer, N., Ashrafian, H., & Giannarou, S. (2021) · Springer eBooks · doi:10.1007/978-3-030-58080-3_323-1 · Cited by 5
Saha, S., Liang, Z., Lin, S., Lu, J., Yip, M. C., & Liu, S. (2025) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv61041.2025.00297 · Cited by 14
Advances in Transanal Quasi-Single-Port Surgery Robotic Systems: A Comprehensive Review
Shi, Y., Li, J., Song, D., Zhang, B., Zhang, Z., Fukuda, T., & Shi, C. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2025.3598580 · Cited by 4
Geodetic coordinate calculation based on monocular vision on UAV platform
Li, Z., Yang, T., Li, G., Li, J., & Zhang, Y. (2016) · International Conference on Signal Processing · doi:10.1109/icsp.2016.7877846 · Cited by 4
Wang, C., Oda, M., Hayashi, Y., Misawa, K., Roth, H. R., & Mori, K. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67543-5_6 · Cited by 4
Metadata
- Authors
- Grasa, O. G., Bernal, E., Casado, S., Gil, I., & Montiel, J. M. M.
- Affiliations
- Hospital Clínico Universitario Lozano Blesa (ES)
- Universidad de Zaragoza (ES)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-01
- Volume
- 33
- Issue
- 1
- Pages
- 135-146
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W1967329161
- Cited by
- 155
- References
- 37
- Citations by year
- 2026: 11 · 2025: 15 · 2024: 10 · 2023: 17 · 2022: 9 · 2021: 20 · 2020: 17 · 2019: 12 · 2018: 9 · 2017: 17 · 2016: 7 · 2015: 4 · 2014: 6
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Robotics and Sensor-Based Localization
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Vision and Imaging
- Physical Sciences › Earth and Planetary Sciences › Geology › 3D Surveying and Cultural Heritage
- Keywords
- visual SLAM, handheld camera, 3D reconstruction, laparoscopic hernia repair, real-time mapping, interpatient variability
- MeSH terms
- Algorithms, Endoscopy, Hernia, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Miniaturization, Pattern Recognition, Automated, Sensitivity and Specificity, User-Computer Interface, Video Recording, Reproducibility of Results, Imaging, Three-Dimensional, Surgery, Computer-Assisted, Herniorrhaphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.