The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Lung Segmentation in Chest Radiographs Using Anatomical Atlases With Nonrigid Registration
Open accessAbstract
The National Library of Medicine (NLM) is developing a digital chest X-ray (CXR) screening system for deployment in resource constrained communities and developing countries worldwide with a focus on early detection of tuberculosis. A critical component in the computer-aided diagnosis of digital CXRs is the automatic detection of the lung regions. In this paper, we present a nonrigid registration-driven robust lung segmentation method using image retrieval-based patient specific adaptive lung models that detects lung boundaries, surpassing state-of-the-art performance. The method consists of three main stages: 1) a content-based image retrieval approach for identifying training images (with masks) most similar to the patient CXR using a partial Radon transform and Bhattacharyya shape similarity measure, 2) creating the initial patient-specific anatomical model of lung shape using SIFT-flow for deformable registration of training masks to the patient CXR, and 3) extracting refined lung boundaries using a graph cuts optimization approach with a customized energy function. Our average accuracy of 95.4% on the public JSRT database is the highest among published results. A similar degree of accuracy of 94.1% and 91.7% on two new CXR datasets from Montgomery County, MD, USA, and India, respectively, demonstrates the robustness of our lung segmentation approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
A performance evaluation of local descriptors
Mikolajczyk, K., & Schmid, C. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.188 · Cited by 6,723
Cootes, T. F., Edwards, G. J., & Taylor, C. J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.927467 · Cited by 5,409
Interactive graph cuts for optimal boundary & region segmentation of objects in N-D images
Boykov, Y. Y., & Jolly, M.-P. (2002) · Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001 · doi:10.1109/iccv.2001.937505 · Cited by 3,674
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Graph Cuts and Efficient N-D Image Segmentation
Boykov, Y., & Funka-Lea, G. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7934-5 · Cited by 1,910 · cited 2×
“We perform image segmentation using graph cuts [34]–[36] and model the segmentation process with an objective function.”
Image Alignment and Stitching: A Tutorial
Szeliski, R. (2007) · Foundations and Trends in Computer Graphics and Vision · doi:10.1561/0600000009 · Cited by 1,593
SIFT Flow: Dense Correspondence across Scenes and Its Applications
Liu, C., Yuen, J., & Torralba, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.147 · Cited by 1,582
Shiraishi, J., Katsuragawa, S., Ikezoe, J., Matsumoto, T., Kobayashi, T., Komatsu, K.-I., Matsui, M., Fujita, H., Kodera, Y., & Doi, K. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.1.1740071 · Cited by 1,004
Multi-atlas based segmentation of brain images: Atlas selection and its effect on accuracy
Aljabar, P., Heckemann, R. A., Hammers, A., Hajnal, J. V., & Rueckert, D. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.018 · Cited by 868
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
van Ginneken, B., Stegmann, M. B., & Loog, M. (2006) · Medical Image Analysis · doi:10.1016/j.media.2005.02.002 · Cited by 539
Active shape model segmentation with optimal features
van Ginneken, B., Frangi, A. F., Staal, J. J., ter Haar Romeny, B. M., & Viergever, M. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803121 · Cited by 529
Computer-aided diagnosis in chest radiography: a survey
Van Ginneken, B., Ter Haar Romeny, B. M., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974918 · Cited by 516
Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
Choosing nodes in parametric curve interpolation
Lee, E. T. Y. (1989) · Computer-Aided Design · doi:10.1016/0010-4485(89)90003-1 · Cited by 393
Svarer, C., Madsen, K., Hasselbalch, S. G., Pinborg, L. H., Haugbøl, S., Frøkjær, V. G., Holm, S., Paulson, O. B., & Knudsen, G. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.017 · Cited by 386
Antani, S., Kasturi, R., & Jain, R. (2002) · Pattern Recognition · doi:10.1016/s0031-3203(01)00086-3 · Cited by 319
Self-citationAutomatic Tuberculosis Screening using Chest Radiographs
Department of Electronics and Communication Engineering, V. T. M. T. D. R. D. S. E. C., Leopauline, S., Kalpana, R., Department of Electronics and Communication Engineering, V. T. M. T. D. R. D. S. E. C., Sharmila, P., & Department of Electronics and Communication Engineering, V. T. M. T. D. R. D. S. E. C. (2019) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.a1507.129219 · Cited by 273
Automatic detection of abnormalities in chest radiographs using local texture analysis
van Ginneken, B., Katsuragawa, S., ter Haar Romeny, B. M., Doi, K., & Viergever, M. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993132 · Cited by 237
Shyu, C.-R., Klaric, M., Scott, G. J., Barb, A. S., Davis, C. H., & Palaniappan, K. (2007) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2006.890579 · Cited by 182
Self-citationWhat metrics can be approximated by geo-cuts, or global optimization of length/area and flux
Kolmogorov, V., & Boykov, Y. (2005) · Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1 · doi:10.1109/iccv.2005.252 · Cited by 167
Shi, Y., Qi, F., Xue, Z., Chen, L., Ito, K., Matsuo, H., & Shen, D. G. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.908130 · Cited by 142
Self-citationAutomatic screening for tuberculosis in chest radiographs: a survey.
Jaeger, S., Karargyris, A., Candemir, S., Siegelman, J., Folio, L. R., Antani, S., & Thoma, G. R. (2013) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-4292.2013.04.03 · Cited by 123
Self-citationPalaniappan, K., Bunyak, F., Kumar, P. M., Ersoy, I., Jaeger, S., Ganguli, K., Haridas, A., Fraser, J., Rao, R. M., & Seetharaman, G. S. (2010) · International Conference on Information Fusion (FUSION) · doi:10.1109/icif.2010.5711891 · Cited by 116
Self-citationAutomated Computer Analysis of Radiographic Images
Meyers, P. H., Nice, C. M., Becker, H. C., Nettleton, W. J., Sweeney, J. W., & Meckstroth, G. R. (1964) · Radiology · doi:10.1148/83.6.1029 · Cited by 100
Detecting tuberculosis in radiographs using combined lung masks
Jaeger, S., Karargyris, A., Antani, S., & Thoma, G. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347110 · Cited by 95
Self-citationMinimal Shape and Intensity Cost Path Segmentation
Seghers, D., Loeckx, D., Maes, F., Vandermeulen, D., & Suetens, P. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.896924 · Cited by 94
Automatic detection of rib borders in chest radiographs
Yue, Z., Ardeshir Goshtasby, A., & Ackerman, L. V. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414618 · Cited by 84
Digital Computer Determination of a Medical Diagnostic Index Directly from Chest X-Ray Images
Becker, H. C., Nettleton, W. J., Meyers, P. H., Sweeney, J. W., & Nice, C. M. (1964) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1964.4502309 · Cited by 81
Xu, T., Mandal, M. K., Long, R., Cheng, I., & Basu, A. (2012) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2012.04.005 · Cited by 69
Shape Particle Filtering for Image Segmentation
de Bruijne, M., & Nielsen, M. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30135-6_21 · Cited by 52
Clavicle segmentation in chest radiographs
Hogeweg, L., Sánchez, C. I., de Jong, P. A., Maduskar, P., & van Ginneken, B. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.06.009 · Cited by 45
Non-rigid motion estimation using the robust tensor method
Palaniappan, K., Jiang, H. S., & Baskin, T. I. (2004) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvpr.2004.405 · Cited by 22
Self-citationMulti-class regularization parameter learning for graph cut image segmentation
Candemir, S., Palaniappan, K., & Akgül, Y. S. (2013) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2013.6556813 · Cited by 20
Self-citationLandmark-Based Non-rigid Registration Via Graph Cuts
Lombaert, H., Sun, Y., & Chériet, F. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-74260-9_15 · Cited by 16
Classification of cell cycle phases in 3D confocal microscopy using PCNA and chromocenter features
Jaeger, S., Palaniappan, K., Casas-Delucchi, C. S., et al. (2010) · Indian Conference on Computer Vision, Graphics and Image Processing · doi:10.1145/1924559.1924614 · Cited by 15
Self-citationStatistical Significance Based Graph Cut Segmentation for Shrinking Bias
Candemir, S., & Akgül, Y. S. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21593-3_31 · Cited by 11
Self-citation
Cited by
MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports
Johnson, A. E. W., Pollard, T. J., Berkowitz, S. J., Greenbaum, N. R., Lungren, M. P., Deng, C.-Y., Mark, R. G., & Horng, S. (2019) · Scientific Data · doi:10.1038/s41597-019-0322-0 · Cited by 1,816
Classification of COVID-19 in chest X-ray images using DeTraC deep convolutional neural network
Abbas, A., Abdelsamea, M. M., & Gaber, M. M. (2021) · Applied Intelligence · doi:10.1007/s10489-020-01829-7 · Cited by 1,124
Two public chest X-ray datasets for computer-aided screening of pulmonary diseases.
(2014) · PubMed Central · doi:10.3978/j.issn.2223-4292.2014.11.20 · Cited by 918
Self-citationMulti-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
Decentralized federated learning: Fundamentals, state of the art, frameworks, trends, and challenges
Martínez Beltrán, E. T., Pérez, M. Q., Sánchez, P. M. S., Bernal, S. L., Bovet, G., Pérez, M. G., Pérez, G. M., & Celdrán, A. H. (2023) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2023.3315746 · Cited by 625
“[173] 2022 Exploit concepts from experience repetition and adversarial generation research Cross-device Centralized Decentralized Simulation GAN FedAvg FedProx FedBN Synchronous Asynchronous Random X-ray data [174], [175] HAM10000 [176]”
Background
Metadata
- Authors
- Candemir, S., Jaeger, S., Palaniappan, K., Musco, J. P., Singh, R. K., Xue, Z., Karargyris, A., Antani, S., Thoma, G., & McDonald, C. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-02
- Volume
- 33
- Issue
- 2
- Pages
- 577-590
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W1994062553
- Cited by
- 674
- References
- 42
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.