The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies
Open accessAbstract
Attenuation correction is an essential requirement for quantification of positron emission tomography (PET) data. In PET/CT acquisition systems, attenuation maps are derived from computed tomography (CT) images. However, in hybrid PET/MR scanners, magnetic resonance imaging (MRI) images do not directly provide a patient-specific attenuation map. The aim of the proposed work is to improve attenuation correction for PET/MR scanners by generating synthetic CTs and attenuation maps. The synthetic images are generated through a multi-atlas information propagation scheme, locally matching the MRI-derived patient's morphology to a database of MRI/CT pairs, using a local image similarity measure. Results show significant improvements in CT synthesis and PET reconstruction accuracy when compared to a segmentation method using an ultrashort-echo-time MRI sequence and to a simplified atlas-based method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“T1 images were corrected for intensity nonuniformity following a nonparametric nonuniform intensity normalization method [24].”
MethodFast free-form deformation using graphics processing units
Modat, M., Ridgway, G. R., Taylor, Z. A., Lehmann, M., Barnes, J., Hawkes, D. J., Fox, N. C., & Ourselin, S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.002 · Cited by 1,085
Self-citationAutomatic anatomical brain MRI segmentation combining label propagation and decision fusion
Heckemann, R. A., Hajnal, J. V., Aljabar, P., Rueckert, D., & Hammers, A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.061 · Cited by 866
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Reconstructing a 3D structure from serial histological sections
Ourselin, S., Roche, A., Subsol, G., Pennec, X., & Ayache, N. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00052-4 · Cited by 547
Self-citationNew, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495
A Generative Model for Image Segmentation Based on Label Fusion
Sabuncu, M. R., Yeo, B. T. T., Van Leemput, K., Fischl, B., & Golland, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2050897 · Cited by 479
STIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
Self-citationMRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
Catana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
Rezaei, A., Defrise, M., Bal, G., Michel, C., Conti, M., Watson, C., & Nuyts, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2212719 · Cited by 261
Minoshima, S., Frey, K. A., Foster, N. L., & Kuhl, D. E. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199507000-00006 · Cited by 252 · cited 1×
“A common practice in the neuro-imaging community is to normalize PET images using a reference region [35], [36].”
BackgroundIconic feature based nonrigid registration: the PASHA algorithm
Cachier, P., Bardinet, E., Dormont, D., Pennec, X., & Ayache, N. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(03)00002-x · Cited by 250
Nearly automatic segmentation of hippocampal subfields in in vivo focal T2-weighted MRI
Yushkevich, P. A., Wang, H., Pluta, J., Das, S. R., Craige, C., Avants, B. B., Weiner, M. W., & Mueller, S. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.040 · Cited by 238
Andersen, F. L., Ladefoged, C. N., Beyer, T., Keller, S. H., Hansen, A. E., Højgaard, L., Kjær, A., Law, I., & Holm, S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.042 · Cited by 190
Simultaneous reconstruction of activity and attenuation in Time-of-Flight PET
Rezaei, A., Nuyts, J., Defrise, M., Bal, G., Michel, C., Conti, M., & Watson, C. (2011) · 2011 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2011.6153883 · Cited by 185
Simultaneous Reconstruction of Activity and Attenuation for PET/MR
Salomon, A., Goedicke, A., Schweizer, B., Aach, T., & Schulz, V. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2095464 · Cited by 174
MR-Based PET Attenuation Correction for PET/MR Imaging
Bezrukov, I., Mantlik, F., Schmidt, H., Schölkopf, B., & Pichler, B. J. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2012.08.002 · Cited by 158
Navalpakkam, B. K., Braun, H., Kuwert, T., & Quick, H. H. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e318283292f · Cited by 122
Schreibmann, E., Nye, J. A., Schuster, D. M., Martín, D. R., Votaw, J. R., & Fox, T. H. (2010) · Medical Physics · doi:10.1118/1.3377774 · Cited by 109
LoAd: A locally adaptive cortical segmentation algorithm
Cardoso, M. J., Clarkson, M. J., Ridgway, G. R., Marc Modat, A., Fox, N. C., & Sebastien Ourselin, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.013 · Cited by 88
Self-citationAccurate PET/MR Quantification Using Time of Flight MLAA Image Reconstruction
Boellaard, R., Hofman, M. B. M., Hoekstra, O. S., & Lammertsma, A. A. (2014) · Molecular Imaging and Biology · doi:10.1007/s11307-013-0716-x · Cited by 88
Bee brains, B-splines and computational democracy: generating an average shape atlas
Torsten Rohlfing, B., Brandt, R., Maurer, C. R., & Menzel, R. (2002) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.2001.991733 · Cited by 88
A comparison of CT- and MR-based attenuation correction in neurological PET
Dickson, J. C., O’Meara, C., & Barnes, A. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2652-z · Cited by 81
Self-citationClinical Positron Emission Tomography/Magnetic Resonance Imaging Applications
von Schulthess, G. K., Kuhn, F. P., Kaufmann, P. A., & Veit‐Haibach, P. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2012.08.005 · Cited by 68
Lee, E. M., Park, G. Y., Im, K. C., Kim, S. T., Woo, C., Chung, J. H., Kim, K. S., Kim, J. S., Shon, Y., Kim, Y.-I., et al. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03432.x · Cited by 67
Johansson, A., Garpebring, A., Karlsson, M. C. F., Asklund, T., & Nyholm, T. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.819119 · Cited by 65
Attenuation Correction Synthesis for Hybrid PET-MR Scanners
Burgos, N., Cardoso, M. J., Marc Modat, A., Pedemonte, S., Dickson, J. C., Barnes, A., Duncan, J. S., Atkinson, D., Arridge, S., Hutton, B. F., et al. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_19 · Cited by 49
Self-citationCardoso, M. J., Wolz, R., Marc Modat, A., Fox, N. C., Rueckert, D., & Sebastien Ourselin, A. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33418-4_33 · Cited by 38
Self-citationMarshall, H. R., Patrick, J. C., Laidley, D. T., Prato, F. S., Butler, J., Théberge, J., Thompson, R. T., & Stodilka, R. Z. (2013) · Medical Physics · doi:10.1118/1.4816301 · Cited by 37
Yang, X., & Fei, B. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001544 · Cited by 32
The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images
Schleyer, P. J., Schaeffter, T., & Marsden, P. K. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32833b0573 · Cited by 28
A symmetric block-matching framework for global registration
Marc Modat, A., Cash, D. M., Daga, P., Winston, G. P., Duncan, J. S., & Sebastien Ourselin, A. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043652 · Cited by 12
Self-citation
Cited by
Medical Image Synthesis with Deep Convolutional Adversarial Networks
Nie, D., Trullo, R., Lian, J., Wang, L., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2814538 · Cited by 625
Image Synthesis in Multi-Contrast MRI With Conditional Generative Adversarial Networks
Dar, S. U., Yurt, M., Karacan, L., Erdem, A., Erdem, E., & Cukur, T. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901750 · Cited by 608
NiftyNet: a deep-learning platform for medical imaging
Gibson, E., Li, W., Sudre, C., Fidon, L., Shakir, D. I., Wang, G., Eaton-Rosen, Z., Gray, R., Doel, T., Hu, Y., et al. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.01.025 · Cited by 552
Self-citationHi-Net: Hybrid-Fusion Network for Multi-Modal MR Image Synthesis
Zhou, T., Fu, H., Chen, G., Shen, J., & Shao, L. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2975344 · Cited by 399
Cardoso, M. J., Modat, M., Wolz, R., Melbourne, A., Cash, D., Rueckert, D., & Ourselin, S. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2418298 · Cited by 344
Self-citation
Metadata
- Authors
- Burgos, N., Cardoso, M. J., Thielemans, K., Modat, M., Pedemonte, S., Dickson, J., Barnes, A., Ahmed, R., Mahoney, C. J., Schott, J. M., Duncan, J. S., Atkinson, D., Arridge, S. R., Hutton, B. F., & Ourselin, S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-12
- Volume
- 33
- Issue
- 12
- Pages
- 2332-2341
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2015897296
- Cited by
- 364
- References
- 37
- FWCI
- 23.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.