The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity
Open accessAbstract
Ultrafast ultrasonic imaging is a rapidly developing field based on the unfocused transmission of plane or diverging ultrasound waves. This recent approach to ultrasound imaging leads to a large increase in raw ultrasound data available per acquisition. Bigger synchronous ultrasound imaging datasets can be exploited in order to strongly improve the discrimination between tissue and blood motion in the field of Doppler imaging. Here we propose a spatiotemporal singular value decomposition clutter rejection of ultrasonic data acquired at ultrafast frame rate. The singular value decomposition (SVD) takes benefits of the different features of tissue and blood motion in terms of spatiotemporal coherence and strongly outperforms conventional clutter rejection filters based on high pass temporal filtering. Whereas classical clutter filters operate on the temporal dimension only, SVD clutter filtering provides up to a four-dimensional approach (3D in space and 1D in time). We demonstrate the performance of SVD clutter filtering with a flow phantom study that showed an increased performance compared to other classical filters (better contrast to noise ratio with tissue motion between 1 and 10mm/s and axial blood flow as low as 2.6 mm/s). SVD clutter filtering revealed previously undetected blood flows such as microvascular networks or blood flows corrupted by significant tissue or probe motion artifacts. We report in vivo applications including small animal fUltrasound brain imaging (blood flow detection limit of 0.5 mm/s) and several clinical imaging cases, such as neonate brain imaging, liver or kidney Doppler imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“removing the N = 60 first components of the singular value decomposition, which optimally exploited the spatiotemporal dynamics of the full Doppler film for clutter rejection, largely outperforming conventional clutter-rejection filters used in Doppler ultrasound47.”
From Local hippocampal fast gamma rhythms precede brain-wide hyperemic patterns during spontaneous rodent REM sleep (2018) · cites this paper as [47]
Citations
Cites
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. N. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 7,048
The approximation of one matrix by another of lower rank
Eckart, C., & Young, G. (1936) · Psychometrika · doi:10.1007/bf02288367 · Cited by 4,497
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,496
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,824
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,157
Self-citationFunctional ultrasound imaging of the brain
Macé, É., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 806
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6689779 · Cited by 697
Self-citationOtazo, R., Candès, E. J., & Sodickson, D. K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 667
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savéry, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 514
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Items 501–600 of 984
Energy based clutter filtering for vector flow imaging
Hoyos, C. A. V., Jensen, J., Ewertsen, C., Hansen, K. L., Nielsen, M. B., & Jensen, J. A. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092639 · Cited by 6
Tierney, J. E., Baker, J. C., Borgmann, A. J., Brown, D. B., & Byram, B. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-49448-8 · Cited by 6
Vascular segmentation of functional ultrasound images using deep learning
Sebia, H., Guyet, T., Pereira, M., Valdebenito, M., Berry, H., & Vidal, B. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110377 · Cited by 5
Xia, Y., Zhang, J., Chen, D., Yin, J., Yu, H., & Zhang, J. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae085f · Cited by 5
3D multiparametric ultrasound imaging of steatotic liver disease in a study with male rats
Lee, D., Heo, J., Mun, H., Oh, D., Ahn, Y. J., & Kim, C. (2025) · Nature Communications · doi:10.1038/s41467-025-65046-x · Cited by 6
Sanabria, S. J., Ruby, L. C., Kuonen, J., Dettwiler, S., Colombo, V. L., Frauenfelder, T., Ettlin, D. A., & Rominger, M. B. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.06.022 · Cited by 5
Sulistyawan, I. G. E., Nishimae, D., Ishii, T., & Saijo, Y. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107424 · Cited by 5
Bonciani, G., Guidi, F., Tortoli, P., Giangrossi, C., Dallai, A., Boni, E., & Ramalli, A. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3474091 · Cited by 5
Human spinal cord activation during filling and emptying of the bladder
Agyeman, K. A., Lee, D. J., Abedi, A., Sakellaridi, S., Kreydin, E. I., Russin, J. J., Lo, Y. T., Wu, K., Choi, W., Iyer, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61470-1 · Cited by 5
Retrobulbar blood flow in rat eyes during acute elevation of intraocular pressure
Silverman, R. H., Urs, R., Tezel, G., Yang, X., Nelson, I., & Ketterling, J. A. (2021) · Experimental Eye Research · doi:10.1016/j.exer.2021.108606 · Cited by 5
Deep Learning for Ultrasound Beamforming
van Sloun, R. J. G., Ye, J. C., & Eldar, Y. C. (2023) · Cambridge University Press eBooks · doi:10.1017/9781009042529.013 · Cited by 5
Independent Component Analysis Filter for Small Vessel Contrast Imaging During Fast Tissue Motion
Wahyulaksana, G., Wei, L., Schoormans, J., Voorneveld, J. D., van der Steen, A. F. W., de Jong, N., & Vos, H. J. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3176742 · Cited by 5
Huang, L., Liu, Y., Wei, X., Hou, X., He, Q., Tong, X.-M., & Luo, J. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9958422 · Cited by 5
Rohlén, R., Lundsberg, J., & Antfolk, C. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01076-0 · Cited by 5
Effect of Clutter Filter in High-Frame-Rate Ultrasonic Backscatter Coefficient Analysis
Omura, M., Yagi, K., Nagaoka, R., Yoshida, K., Yamaguchi, T., & Hasegawa, H. (2023) · Sensors · doi:10.3390/s23052639 · Cited by 5
Chen, J., Goubran, M., Kim, G., Kim, M., Willmann, J. K., Zeineh, M., Hristov, D. H., & Kaffas, A. E. (2024) · Medical Physics · doi:10.1002/mp.16995 · Cited by 5
Vector-flow imaging of slowly moving ex vivo blood with photoacoustics and pulse-echo ultrasound
Smith, C., Shepherd, J., Renaud, G., & van Wijk, K. (2024) · Photoacoustics · doi:10.1016/j.pacs.2024.100602 · Cited by 5
TOBE-Costas Arrays for Fast High-Resolution 3-D Power Doppler Imaging
Masoumi, M. H., Kaddoura, T., & Zemp, R. J. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3400229 · Cited by 5
A transcranial multiple waves suppression method for plane wave imaging based on Radon transform
Pan, Y., Yu, Q., Liang, W., Huang, W., Wang, N., Wang, X., Zhang, Z., Qiu, W., & Zheng, H. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107405 · Cited by 5
Lok, U., Song, P., Trzasko, J. D., Borisch, E. A., Daigle, R. E., & Chen, S. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579678 · Cited by 5
Ashikuzzaman, M., Belasso, C. J., Gauthier, C. J., & Rivaz, H. J. (2019) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2019.8759543 · Cited by 5
Super-Resolution Ultrasound Image Filtering with Machine-Learning to Reduce the Localization Error
Harput, S., Grisan, E., Dunsby, C. W., Tang, M., Fong, L. H., Stanziola, A., Zhang, G., Toulemonde, M. E. G., Zhu, J., Christensen-Jeffries, K. M., et al. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925861 · Cited by 5
Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters
Zhu, Y., Kim, M., Hoerig, C. L., & Insana, M. F. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.2989109 · Cited by 5
Torres, A., Palmeri, M. L., Feltovich, H. M., Hall, T. J., & Rosado-Méndez, I. M. (2021) · Frontiers in Physics · doi:10.3389/fphy.2020.606664 · Cited by 5
Preliminary investigation on clutter filtering based on deep learning
Wang, H., Gao, S., Mozumi, M., Omura, M., Nagaoka, R., & Hasegawa, H. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/abf39d · Cited by 6
Fialho, M. A., Alberdi, L. V., Martínez, M., Calero, M., Baranger, J., Tanter, M., Damián, J. P., Negreira, C., Rubido, N., Kun, A., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-10457-9 · Cited by 4
Self-citationBhatti, A., Kanno, N., Ikeda, H., Ishii, T., & Saijo, Y. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871304 · Cited by 5
A High-Efficiency Super-Resolution Reconstruction Method for Ultrasound Microvascular Imaging
Guo, W., Tong, Y., Huang, Y., Wang, Y., & Yu, J. (2018) · Applied Sciences · doi:10.3390/app8071143 · Cited by 5
Wall clutter removal in Doppler ultrasound using principal component pursuit
Chau, G. R., Li, Y. L., Jakovljevic, M., Dahl, J., & Rodríguez, P. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579699 · Cited by 5
Speckle coherence of piecewise-stationary stochastic targets
Morgan, M. R., Trahey, G. E., & Walker, W. F. (2019) · The Journal of the Acoustical Society of America · doi:10.1121/1.5126686 · Cited by 5
Piepenbrock, M., Dencks, S., & Schmitz, G. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925566 · Cited by 5
Energy based clutter filtering for vector flow imaging
Hoyos, C. A. V., Jensen, J., Ewertsen, C., Hansen, K. L., Nielsen, M. B., & Jensen, J. A. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8091616 · Cited by 5
Soylu, U., & Bresler, Y. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2101.09470 · Cited by 5
3D Ultrasound Localization Microscopy
Heiles, B. (2019) · doi:10.70675/5bbb9ab3z04f5z41cez9f2cz1705ad58d89f · Cited by 5
Li, M., Liang, S., & Lu, M. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad7224 · Cited by 4
Bhatti, A., Ishii, T., Lafond, M., & Saijo, Y. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.05.022 · Cited by 4
Contrast-Free Super-Resolution microvascular imaging through high frequency ultrasound imaging
Li, C., Huang, H., Lin, C.-Y., Chen, D., Chuang, Y.-H., Chen, C., & Huang, C. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107843 · Cited by 4
Investigation of ultrasound plane-wave imaging for optimal synthetic focusing
Jang, D., Park, J., Song, J. H., Song, T., & Yoon, H. (2025) · Scientific Reports · doi:10.1038/s41598-025-30595-0 · Cited by 4
Lee, S. A., Leconte, A., Wu, A., Kinugasa, J., Ramos-Palacios, G., Porée, J., Sadikot, A. F., Linninger, A. A., & Provost, J. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2509564123 · Cited by 4
Time-Lagged Functional Ultrasound for Multi-Parametric Cerebral Hemodynamic Imaging
Liu, B., Wang, Y., Fomin-Thunemann, N., Thunemann, M., Kılıç, K., Devor, A., Cheng, X., Tan, J., Jiang, J., Boas, D. A., et al. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3314734 · Cited by 4
Developments in angle-independent velocity estimators for blood flow imaging
Hasegawa, H. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad32e3 · Cited by 4
Wang, D., Qiao, W., Su, Q., Wang, S., Jian, Z., Li, J., Ye, F., Hou, Y., & Wan, M. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3408636 · Cited by 4
Optical coherence tomography guided automatic robotic craniotomy surgery platform
Li, H., Wang, Y., Chen, W., Zhang, Y., Guo, X., Xu, L. T., Bao, Y., Zhou, J., Sun, H., Bi, Y., et al. (2025) · Biomedical Optics Express · doi:10.1364/boe.549260 · Cited by 4
Bayat, M., Alizad, A., & Fatemi, M. (2018) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2018.8363781 · Cited by 4
Recursive Imaging for Tracking High Density Scatterers in Super-Resolution Imaging
Naji, M. A., Taghavi, I., Larsen, N. B., Thomsen, E. V., Sørensen, C. M., & Jensen, J. A. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10306650 · Cited by 4
Maru, T., Omura, M., Nagaoka, R., Saito, K., & Hasegawa, H. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad2fe3 · Cited by 4
Microbubble Contrast Agents Improve Detection of Active Hemorrhage
Schoen, S. J., Prasov, A., Candel, I., Arshad, S. H., Ottensmeyer, M. P., Pierce, T. T., Brattain, L. J., Telfer, B. A., & Samir, A. E. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3414974 · Cited by 4
Three-Dimensional Super-Resolution Passive Cavitation Mapping in Laser Lithotripsy
Li, D., Wang, N., Li, M., Mishra, A., Tang, Y., Vu, T., Xiang, G., Chen, J., Lipkin, M. E., Zhong, P., et al. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3443781 · Cited by 4
Sabeti, S., Fatemi, M., & Alizad, A. (2024) · IEEE Access · doi:10.1109/access.2024.3446531 · Cited by 4
Improving microvascular sensitivity of color Doppler using phase mask based flow recycling algorithm
Yu, H. Y., Zhang, J., Yin, J., Yang, J., Chen, D., Xia, Y., & Zhang, J. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad8292 · Cited by 4
Jiang, L., Chu, H., Liu, Y., Liu, J., Su, X., Yan, Y., Liang, M., Chen, Y. H., Zhang, C., Wang, F., et al. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3470975 · Cited by 4
Nguyen, M. B., Zhang, N., Mertens, L., Barron, D. J., Honjo, O., Venet, M., Baranger, J., & Villemain, O. (2025) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyaf007 · Cited by 4
Precision of in vivo pressure gradient estimations using synthetic aperture ultrasound
Haslund, L. E., Henriksen, A. C., Yiu, B. Y. S., Salari, A., Traberg, M. S., Jørgensen, L. T., Tomov, B. G., Nielsen, M. B., & Jensen, J. A. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107574 · Cited by 4
Plomp, J., Ghanbarzadeh-Dagheyan, A., Versluis, M., Lajoinie, G. P. R., & Jebbink, E. G. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.02.012 · Cited by 4
Vascular ultrasound imaging with flexible wearable array
Cheng, S., Zou, J., Yan, S., Xu, L., Dai, J., Chen, P., & Xu, K. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/adcce9 · Cited by 4
Amplitude-Modulated Singular Value Decomposition for Ultrafast Ultrasound Imaging of Gas Vesicles
Zhang, G., Vert, M., Nouhoum, M., Rivera, E., Haidour, N., Jimenez, A., Deffieux, T., Barral, S., Hersen, P., Pezet, S., et al. (2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2025.3565023 · Cited by 4
Self-citationPROTEUS: A Physically Realistic Contrast-Enhanced Ultrasound Simulator—Part II: Imaging Applications
Heiles, B., Blanken, N., Kuliesh, A., Versluis, M., Jain, K., Lajoinie, G. P. R., & Maresca, D. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3566437 · Cited by 4
Hoving, A. M., de Vries, E. E., Voorneveld, J. D., Jebbink, E. G., Mikhal, J., Versluis, M., Bosch, J. G., de Jong, N., de Borst, G. J., & Slump, C. H. (2018) · SPIE Medical Imaging: Ultrasonic Imaging and Tomography · doi:10.1117/12.2293669 · Cited by 4
Closed-Loop Low-Rank Echocardiographic Artifact Removal
Govinahallisathyanarayana, S., Acton, S. T., & Hossack, J. A. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.3013268 · Cited by 4
A New Plane Wave Compounding Scheme Using Phase Compensation for Motion Detection
Lee, H.-K., Greenleaf, J. F., & Urban, M. W. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3136127 · Cited by 4
Flow imaging using differential Golay encoded ultrasound
Nowicki, A., Tasinkiewicz, J., & Trots, I. (2022) · Ultrasonics · doi:10.1016/j.ultras.2022.106825 · Cited by 4
Fast and Robust Clutter Filtering in Ultrafast Echocardiography
Xu, Y., Yiu, K., & Lee, W.-N. (2022) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2022.09.013 · Cited by 4
Microbubble detection with adaptive beamforming for Ultrasound Localization Microscopy
Corazza, A., Muleki-Seya, P., Aissani, A. W., Couture, O., Basarab, A., & Nicolas, B. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9958516 · Cited by 4
Advanced Fourier migration for Plane-Wave vector flow imaging
Liang, S., & Lu, M. (2023) · Ultrasonics · doi:10.1016/j.ultras.2023.107001 · Cited by 4
Comparative Study of Histotripsy Pulse Parameters Used to Inactivate Escherichia coli in Suspension
Ambekar, P. A., Wang, Y.-N., Khokhlova, T. D., Bruce, M. F., Leotta, D. F., Totten, S., Maxwell, A. D., Chan, K. T., Liles, W. C., Dellinger, E. P., et al. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.08.004 · Cited by 4
Xie, Y., Huang, Y., Stevenson, H. C. S., Li, Y., Zhang, K., Islam, Z. H., Marcum, W. A., Johnston, C., Hoyt, N. E., Kent, E. W., et al. (2024) · Biomedicines · doi:10.3390/biomedicines12010200 · Cited by 4
Vector Flow Velocity Estimation from Beamsummed Data Using Deep Neural Networks
Li, Y. L., Hyun, D., & Dahl, J. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925825 · Cited by 4
Lang, X., He, B., Zhang, Y., Chen, Q., & Xie, L. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593919 · Cited by 4
Generowicz, B. S., Leus, G. J. T., Soloukey, S., van Hoogstraten, W. S., Strvdis, C., Bosch, J. G., van der Steen, A. F. W., de Zeeuwl, C. I., Koekkoek, S. K. E., & Kruizinga, P. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579775 · Cited by 4
Bataghva, M., Johnston, D. E., Power, N. E., Peñuela, S., & Lacefield, J. C. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251730 · Cited by 4
Adaptive clutter filtering based on tissue vector velocities
Ekroll, I. K., & Avdal, J. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8091995 · Cited by 4
Volumetric ultrasound localization microscopy of the whole brain microvasculaturePreprint
Couture, O., Heiles, B., Hingot, V., Serroune, H., Maresca, D., Pezet, S., Pernot, M., Tanter, M., Chavignon, A., & Bergel, A. (2022) · Research Square · doi:10.21203/rs.3.rs-1198910/v1 · Cited by 4
Self-citationHigh-Volume Acquisition Rate Nonlinear Imaging Enables Robust 3-D Ultrasound Localization Microscopy
Shin, Y., Lin, B., Lowerison, M. R., You, Q., & Song, P. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3589815 · Cited by 3
An Adaptive SVD-Based Approach to Clutter Suppression for Slow-Moving Targets
Hou, Y., & Chen, B. (2025) · Remote Sensing · doi:10.3390/rs17152697 · Cited by 3
Brain-Wide Transcranial Ultrasound Localization Microscopy of the Nonhuman Primate
Guo, Y., Sun, Q., Xie, Y., Minonzio, J.-G., Xu, K., & Ta, D. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3611501 · Cited by 3
Wang, T., Zhang, Y., Chen, J., Chen, P., Kandi, F. I., Yao, J., Wu, Q., Turco, S., Mischi, M., & Huang, P. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.08.030 · Cited by 3
High sensitivity ultrasound microvessel imaging for the assessment of placental health
Santos, J., Lok, U., Chen, S., Huang, C., & Enninga, E. A. L. (2026) · Placenta · doi:10.1016/j.placenta.2026.01.020 · Cited by 3
Baseband delay multiply and sum beamformer for three-dimensional ultrasound localization microscopy
Li, Z., Zhang, Z., Xiong, J., He, Q., & Luo, J. (2026) · Ultrasonics · doi:10.1016/j.ultras.2026.108043 · Cited by 3
Combined thermography and ultrasound in hidradenitis suppurativa: A preliminary study
Margiotta, F. M., Kourtellari, E., Michelucci, A., Romanelli, M., Dini, V., & Zouboulis, C. C. (2026) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.70429 · Cited by 3
Enhanced visibility through microbubble-induced photoacoustic fluctuation imaging
Inzunza-Ibarra, M. A., Navarro-Becerra, J. Á., Narumanchi, V. V., Bottenus, N. B., Murray, T. W., & Borden, M. A. (2022) · JASA Express Letters · doi:10.1121/10.0009129 · Cited by 3
Contrast-Free Transcranial Functional Ultrasound Neuroimaging
Vienneau, E. P., Weeks, A. E., Wilson, S. M., Morgan, V. L., & Byram, B. C. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10306684 · Cited by 3
Wei, X., Huang, L., Lan, H., & Luo, J. (2024) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi56570.2024.10635245 · Cited by 3
3-D motion tracking and vascular strain imaging using bistatic dual aperture ultrasound acquisitions
de Hoop, H., Maas, E. J., Muller, J.-W., Schwab, H., & Lopata, R. G. P. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad9db2 · Cited by 3
Han, W., Zhou, W., Huang, L., Luo, J., & Peng, B. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3544692 · Cited by 3
Tsedendamba, N., Vial, J., Taylor, R. A., Kim, J., & Choi, W. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/adc4a6 · Cited by 3
Contrast-ultrasound dispersion imaging for renal cell carcinoma diagnostics
Chen, P., Turco, S., Liu, Z., Widdershoven, C., Oddens, J. R., Wijkstra, H., Mischi, M., & Zondervan, P. J. (2025) · The Ultrasound Journal · doi:10.1186/s13089-025-00423-7 · Cited by 3
Nondestructive Ultrasound Molecular Imaging With Higher Order Singular Value Decomposition
Collado‐Lara, G., Wahyulaksana, G., Vos, H. J., & Kooiman, K. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3578895 · Cited by 3
Perfusion imaging with non-contrast ultrasound
Tierney, J. E., Dumont, D. M., & Byram, B. C. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216901 · Cited by 3
Byram, B. C., Towse, T. F., George, M. K., Tierney, J. E., & Coolbaugh, C. L. (2018) · SPIE Medical Imaging: Ultrasonic Imaging and Tomography · doi:10.1117/12.2291943 · Cited by 3
High-Framerate Dynamic Contrast-Enhanced Ultrasound Imaging of Rat Kidney Perfusion
Le, D., Chang, E., Dayton, P. A., & Johnson, K. A. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8926166 · Cited by 3
Barthelemy, C. R., Koury, E., Beuve, S., Zemmoura, I., Gennisson, J., Bassarab, A., Kouamé, D., & Réméniéras, J.-P. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925955 · Cited by 3
Self-citationFeng, S., Wang, Y., Zheng, C., Han, Z., & Peng, H. (2020) · Applied Sciences · doi:10.3390/app10165595 · Cited by 3
Ultrafast Ultrasound Imaging for Micro-Nanomotors: A Phantom Study
Yan, S., Liu, J., Guo, X., Ta, D., Huang, G., Solovev, A. A., Mei, Y., & Xu, K. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593877 · Cited by 3
Adaptive clutter filtering based on tissue vector velocities
Ekroll, I. K., & Avdal, J. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092049 · Cited by 3
Single-Sided Ultrasound Imaging of the Bone Cortex: Anatomy, Tissue Characterization and Blood Flow
Renaud, G., & Salles, S. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-91979-5_10 · Cited by 3
Rowland, E. M., Riemer, K., Lichtenstein, K. M., Tang, M., & Weinberg, P. D. (2022) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2022.09.016 · Cited by 3
Hasegawa, H., Omura, M., Nagaoka, R., & Saito, K. (2022) · Sensors · doi:10.3390/s22249787 · Cited by 3
Monitoring Muscle Perfusion in Rodents During Short-Term Ischemia Using Power Doppler Ultrasound
Babaei, S., Dai, B., Abbey, C. K., Ambreen, Y., Dobrucki, L. W., & Insana, M. F. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.02.013 · Cited by 3
Microbubble Identification Based on Decision Theory for Ultrasound Localization Microscopy
Corazza, A., Muleki-Seya, P., Basarab, A., & Nicolas, B. (2023) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2023.3274512 · Cited by 3
Sarkar, M., Pérez-Liva, M., Renault, G., Tavitian, B., & Gâteau, J. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3306592 · Cited by 3
Metadata
- Authors
- Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., Cohen, I., Baud, O., & Tanter, M.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Inserm (FR)
- ORCID
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2015-11
- Volume
- 34
- Issue
- 11
- Pages
- 2271-2285
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2070712157
- Cited by
- 983
- References
- 39
- Citations by year
- 2026: 79 · 2025: 137 · 2024: 120 · 2023: 107 · 2022: 102 · 2021: 103 · 2020: 95 · 2019: 80 · 2018: 71 · 2017: 56 · 2016: 27 · 2015: 6
- FWCI
- 43.18
- Type
- journal article
- Language
- en
- Open access
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- HAL (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-10-IDEX-0001)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- ultrafast ultrasound imaging, clutter suppression, Doppler imaging, blood flow detection, tissue motion, microvascular networks, neonatal brain imaging
- MeSH terms
- Animals, Blood Flow Velocity, Echoencephalography, Humans, Image Processing, Computer-Assisted, Infant, Newborn, Kidney, Signal Processing, Computer-Assisted, Models, Statistical, Rats, Sprague-Dawley, Ultrasonography, Doppler, Phantoms, Imaging, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review