Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity
Open accessAbstract
Ultrafast ultrasonic imaging is a rapidly developing field based on the unfocused transmission of plane or diverging ultrasound waves. This recent approach to ultrasound imaging leads to a large increase in raw ultrasound data available per acquisition. Bigger synchronous ultrasound imaging datasets can be exploited in order to strongly improve the discrimination between tissue and blood motion in the field of Doppler imaging. Here we propose a spatiotemporal singular value decomposition clutter rejection of ultrasonic data acquired at ultrafast frame rate. The singular value decomposition (SVD) takes benefits of the different features of tissue and blood motion in terms of spatiotemporal coherence and strongly outperforms conventional clutter rejection filters based on high pass temporal filtering. Whereas classical clutter filters operate on the temporal dimension only, SVD clutter filtering provides up to a four-dimensional approach (3D in space and 1D in time). We demonstrate the performance of SVD clutter filtering with a flow phantom study that showed an increased performance compared to other classical filters (better contrast to noise ratio with tissue motion between 1 and 10mm/s and axial blood flow as low as 2.6 mm/s). SVD clutter filtering revealed previously undetected blood flows such as microvascular networks or blood flows corrupted by significant tissue or probe motion artifacts. We report in vivo applications including small animal fUltrasound brain imaging (blood flow detection limit of 0.5 mm/s) and several clinical imaging cases, such as neonate brain imaging, liver or kidney Doppler imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“removing the N = 60 first components of the singular value decomposition, which optimally exploited the spatiotemporal dynamics of the full Doppler film for clutter rejection, largely outperforming conventional clutter-rejection filters used in Doppler ultrasound47.”
From Local hippocampal fast gamma rhythms precede brain-wide hyperemic patterns during spontaneous rodent REM sleep (2018) · cites this paper as [47]
Citations
Cites
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. N. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 7,048
The approximation of one matrix by another of lower rank
Eckart, C., & Young, G. (1936) · Psychometrika · doi:10.1007/bf02288367 · Cited by 4,497
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,496
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,824
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,157
Self-citationFunctional ultrasound imaging of the brain
Macé, É., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 806
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6689779 · Cited by 697
Self-citationOtazo, R., Candès, E. J., & Sodickson, D. K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 667
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savéry, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 514
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Items 601–700 of 984
Huang, L., Liu, Y., Wei, X., Hou, X., Wang, R., Tong, X.-M., & Luo, J. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10306587 · Cited by 3
Generowicz, B. S., Dijkhuizen, S., Bosman, L. W. J., Zeeuw, C. I. D., Koekkoek, S. K. E., & Kruizinga, P. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3330343 · Cited by 3
Desmarais, S., Ramos-Palacios, G., Porée, J., Lee, S. A., Leconte, A., Sadikot, A. F., & Provost, J. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad199a · Cited by 3
3D U-Net3+ Based Microbubble Filtering for Ultrasound Localization Microscopy
Han, W., Zhang, Y., Zhao, Y., Luo, A., & Peng, B. (2023) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53992.2023.10394576 · Cited by 3
Tempestti, J. M., Kim, S., Lindsey, B. D., & Veneziani, A. (2024) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-024-00741-2 · Cited by 3
Deep Power-Aware Tunable Weighting for Ultrasound Microvascular Imaging
Lan, H., Huang, L., Wang, Y., Wang, R., Wei, X., He, Q., & Luo, J. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3488729 · Cited by 3
Ultrafast ultrasound coded vector Doppler imaging of blood flow velocity and resistivity
Shaoyuan, Y. A. N., Ding, Y., Guoao, M. A., Fu, Y., Xu, K., & Ta, D. (2024) · Acta Physica Sinica · doi:10.7498/aps.74.20241454 · Cited by 3
Spatiotemporal Filtering for Synthetic Aperture Slow Flow Imaging
Olleros, G. G., Hoyos, C. A. V., Hansen, K. L., Stuart, M. B., & Jensen, J. A. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579611 · Cited by 3
Erol, A., Eyndhoven, S. V., Koekkoek, S. K. E., Kruizinga, P., & Hunyadi, B. (2020) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf51394.2020.9443299 · Cited by 3
Decoding behavior from global cerebrovascular activity using neural networks
Berthon, B., Bergel, A., Matei, M., & Tanter, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-30661-5 · Cited by 3
Self-citationEfficiency of U.S. Tissue Perfusion Estimators
Kim, M., Abbey, C. K., & Insana, M. F. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2571979 · Cited by 3
Kaddoura, T., Au, A. G., Kawchuk, G. N., Uwiera, R. R. E., Fox, R., & Zemp, R. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-27816-0 · Cited by 3
Wildeboer, R. R., van Sloun, R. J. G., Mannaerts, C. K., van der Linden, J. C., Huang, P., Wijkstral, H., & Mischi, M. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579730 · Cited by 3
Adaptive hybrid flow measurement of color Doppler and speckle image velocimetry
Park, J. H., Choi, W., & Lee, S. J. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106093 · Cited by 3
Insana, M. F., Dai, B., Babaei, S., & Abbey, C. K. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3211469 · Cited by 3
Bataghva, M., Johnston, D. E., Power, N. E., Peñuela, S., & Lacefield, J. C. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251742 · Cited by 3
Apelian, C., Harms, F., Thouvenin, O., & Boccara, C. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1601.01208 · Cited by 3
Miniaturized Four-Dimensional Functional Ultrasound for Mapping Human Brain ActivityPreprint
Verhoef, L., Soloukey, S., Springeling, G., Flikweert, A. J., Lippe, B., de Jong, A. J., Radeljic-Jakic, N., Baas, M., Voorneveld, J. D., Vincent, A. J. P. E., et al. (2025) · medRxiv · doi:10.1101/2025.08.19.25332261 · Cited by 3
Acoustic Transparency Enabling Functional Ultrasound Imaging Through Mouse and Human SkullsPreprint
Wang, Z., Kou, Z., Zhang, J., Li, J., Gong, C., Lin, C., Wu, J., Oelze, M. L., Zhou, Q., & Yang, Y. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.08.22.671878 · Cited by 3
Assessment of Coronary Microcirculation with High Frame-Rate Contrast-Enhanced Echocardiography
Wahyulaksana, G., Wei, L., Voorneveld, J. D., Hekkert, M. T. L., Bowen, D. J., Strachinaru, M., Duncker, D. J., van der Steen, A. F. W., & Vos, H. J. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2024.12.002 · Cited by 2
Matsuzaki, M., Omura, M., Nagaoka, R., & Hasegawa, H. (2025) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/adbdd9 · Cited by 2
Zhang, Y., Chen, H., Yuan, J., Wang, Z., Zhang, Y., Chen, S., Chen, X., & Lin, H. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.07.045 · Cited by 2
Jeong, H., Yoon, C., Sung, M., Kim, K., Park, D., & Kim, C. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-05325-1_43 · Cited by 2
Seong, H., Jung, J., Jung, D., Guezzi, N., Nam, S., Lee, S., Noman, M., Her, T., Cho, E., Yoon, H., et al. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107849 · Cited by 2
Human Mole Contrast-Free Microvascular Imaging using Erythrocytes
Salari, A., Falkentoft, R. B. B., Naji, M. A., Tomov, B. G., Nielsen, M. B., & Jensen, J. A. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201667 · Cited by 2
Real-Time SVD Clutter Filtering using Preconditioning
Præsius, S. K., Batenburg, K. J., & Jensen, J. A. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201625 · Cited by 2
Maeda, K., Omura, M., Sukhbaatar, A., Sugiura, T., & Kodama, T. (2025) · Scientific Reports · doi:10.1038/s41598-025-27268-3 · Cited by 2
Dynamic mode decomposition as a framework for denoising ultrafast power doppler images
Pialot, B., Guidi, F., Muleki-Seya, P., Boni, E., Ramalli, A., & Varray, F. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.109221 · Cited by 2
Photo-activated ultrasound localization imaging with laser-activated nanodroplets
Zhao, S., Yi, J., Qiu, Y., Huang, Z., & Chen, Y. (2026) · Communications Engineering · doi:10.1038/s44172-026-00592-w · Cited by 2
Jeong, D.-Y., Ahn, J. H., Choi, W., Lee, H.-B., Kweon, J. Y., Oh, H., Kwon, S. U., Lee, J. S., Sung, M., Oh, D., et al. (2026) · Stroke · doi:10.1161/strokeaha.125.053896 · Cited by 2
Bodard, S., Denis, L., Pradier, B., Chabouh, G., Hélénon, O., Corréas, J.-M., Riella, L. V., & Couture, O. (2026) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.12.011 · Cited by 2
Adaptive Transcranial Ultrasound Doppler Imaging of the Brain
Waasdorp, R., Muñoz-Ibarra, E., Nelissen, F., Heiles, B., Gazzola, V., Renaud, G., & Maresca, D. (2026) · IEEE Transactions on Ultrasonics · doi:10.1109/tuson.2026.3675441 · Cited by 2
Pereira, M., Vidal, B., Valdebenito, M., Cheataini, F., Bouillot, C., Vidal, L., Nestor, L., Bundel, D. D., Smolders, I. J., Droguerre, M., et al. (2026) · Glia · doi:10.1002/glia.70171 · Cited by 2
Mar, S., Chérin, E., Xu, J., Goertz, D. E., Leong, H. S., & Demore, C. E. M. (2026) · Journal of Ultrasound in Medicine · doi:10.1002/jum.70353 · Cited by 2
Perfusion flow phantoms with many variably oriented microchannels
George, M. K., Tierney, J. E., Luchies, A. C., Faley, S. L., Ozgun, K. A., Bellan, L. M., & Byram, B. C. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092310 · Cited by 2
Pernot, M., & Goudot, G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817195-0.00022-6 · Cited by 2
Self-citationA Channel Domain Higher-Order SVD Clutter Rejection Filter for Small Vessel Ultrasound Imaging
Ozgun, K. A., & Byram, B. C. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251419 · Cited by 2
Kim, S., Jing, B., Veneziani, A., & Lindsey, B. D. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593916 · Cited by 2
Godefroy, G., Arnal, B., Вилов, С. А., & Bossy, E. (2021) · Opto-Acoustic Methods and Applications in Biophotonics · doi:10.1117/12.2615874 · Cited by 2
MR for ULTRA-SR: Improved Localization with Morphological Image Processing
Schoen, S. J., Samir, A. E., & Kumar, V. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9957276 · Cited by 2
A locally adaptive Casorati-SVD clutter filtering to improve ultrafast color Doppler imaging
Pan, L., He, B., Zhang, K., Lang, X., & Zhang, Y. (2022) · IEEE International Conference on Frontiers Technology of Information and Computer (ICFTIC) · doi:10.1109/icftic57696.2022.10075222 · Cited by 2
Spatially segmented SVD clutter filtering in cardiac blood flow imaging with diverging waves
Jafarzadeh, E., Demore, C. E. M., Burns, P. N., & Goertz, D. E. (2023) · Ultrasonics · doi:10.1016/j.ultras.2023.107006 · Cited by 2
Nayak, R., Lee, J., Korani, S. S., Chang, S.-Y., Fatemi, M., & Alizad, A. (2023) · Sensors · doi:10.3390/s23156902 · Cited by 2
Topology-Aware Brain Vessel Segmentation in Ultrafast Doppler Imaging
Chen, D., Xia, Y., Zhao, Y., Qian, X., Yin, J., Li, D., Zhang, J., & Zhang, J. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10307549 · Cited by 2
Wang, B., Riemer, K., Toulemonde, M. E. G., Yan, J., Zhou, X., Smith, C. A. B., & Tang, M. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3343992 · Cited by 2
Specific and non-uniform brain states during cold perception in mice
Koorliyil, H., Sitt, J. D., Rivals, I., Liu, Y., Cazzanelli, S., Bertolo, A., Dizeux, A., Deffieux, T., Tanter, M., & Pezet, S. (2024) · Journal of Neuroscience · doi:10.1523/jneurosci.0909-23.2023 · Cited by 2
Self-citationYoshida, K., Omura, M., Tamura, K., Hirata, S., & Yamaguchi, T. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3357140 · Cited by 2
Detecting heart failure from B-mode ultrasound characterization of arterial pulse waves
Reavette, R. M., Ramakrishnan, A., Rowland, E. M., Tang, M., Mayet, J., & Weinberg, P. D. (2024) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00219.2024 · Cited by 2
Fast Spline Interpolation using GPU Acceleration
Præsius, S. K., & Jensen, J. A. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793976 · Cited by 2
Near-Field Clutter Mitigation in Speckle Tracking Echocardiography
Xu, Y., Yiu, K., & Lee, W.-N. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2024.12.016 · Cited by 2
Omura, M., Yagi, K., Nagaoka, R., Yoshida, K., Yamaguchi, T., & Hasegawa, H. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107589 · Cited by 2
Beliard, B., Delay, L., Travert-Jouanneau, Y., Travert-Jouanneau, Y., Ialy-Radio, N., Goazigo, A. R.-L., Deffieux, T., Bradley, D. P., Tanter, M., & Pezet, S. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00534 · Cited by 2
Self-citationCorrecting for sub-resolution tissue motion in localization optoacoustic tomography
Zhao, J., Nozdriukhin, D. V., Razansky, D., & Deán‐Ben, X. L. (2025) · Optics Letters · doi:10.1364/ol.557507 · Cited by 2
Liang, S., Han, P., Xiang, F., Zhu, L., Peng, L., Xie, F., & Luo, Y. (2025) · BMC Cancer · doi:10.1186/s12885-025-14238-1 · Cited by 2
Liang, D., Zhang, J., Wang, D., Qian, X., Dong, F., Yang, J., Bao, Y., & Zhang, J. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107718 · Cited by 2
Multimodal Neuroimaging for the PK/PD Profile of NLX-204: A Biased 5-HT1A Receptor Agonist
Richin, V., Valdebenito, M., Bouillot, C., Bouvard, S., Daligault, S., Vidal, B., Newman‐Tancredi, A., Zeinyeh, W., & Zimmer, L. (2025) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.5c00342 · Cited by 2
Randomized Spatial Downsampling based Robust PCA Clutter Filtering for Ultrafast Ultrasound Imaging
Sui, Y., Yan, S., Zang, J., Liu, X., Ta, D., Wang, W., & Xu, K. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593583 · Cited by 2
Spatiotemporal Nonlocal Means Based Denoising for Ultrasound Microvascular Imaging
Huang, L., Zhang, J., Hao, Y., Jing, L., He, Q., Wang, G., Liao, H., & Luo, J. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593725 · Cited by 2
Wang, Y., Zheng, C., Peng, H., & Wang, Y. (2022) · Applied Sciences · doi:10.3390/app122110973 · Cited by 2
3D Functional Ultrasound using a Continuously Moving Linear Stage
Generowicz, B. S., Dijkhuizen, S., Zeeuw, C. I. D., Koekkoek, S. K. E., & Kruizinga, P. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9957564 · Cited by 2
Huang, L., Wang, Y., Wang, R., Lan, H., Wei, X., Zheng, C., Peng, H., & Luo, J. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10306753 · Cited by 2
In vivo imaging of ocular blood flow using high-speed ultrasound
Ketterling, J. A., Urs, R., & Silverman, R. H. (2016) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2016.7728578 · Cited by 2
Dual frequency transcranial ultrasound for contrast enhanced ultrafast brain functional imaging
Robins, T., Leow, C. H., Chapuis, G. A., Chadderton, P. T., & Tang, M. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092274 · Cited by 2
Tierney, J. E., Wilkes, D. M., & Byram, B. C. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8580150 · Cited by 2
Low-Rank Adaptive Clutter Filtering for Robust Ultrasound Vector Flow Imaging
Du, Y., Zhang, M., Yu, A. C. H., & Yu, W. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8580077 · Cited by 2
Tierney, J. E., Baker, J. C., Ozgun, K. A., Borgmann, A. J., Brown, D. B., & Byram, B. C. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579939 · Cited by 2
Correlation-based Doppler-angle estimation with plane-wave excitation
Lok, U., Lin, F.-Y., Yeh, C.-L., & Li, P. (2020) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2020.100315 · Cited by 2
Jiao, Y., Zhang, D., Xu, Y., Yang, C., Wu, Z., & Cui, Y. (2020) · Applied Sciences · doi:10.3390/app10217604 · Cited by 2
Toulemonde, M. E. G., Harput, S., Tiennot, T., Zhou, X., & Tang, M. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251319 · Cited by 2
Pham, D.-H., Basarab, A., Réméniéras, J.-P., Rodríguez, P., & Kouamé, D. (2021) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi48211.2021.9433816 · Cited by 2
Registration methods in power Doppler ultrasound for peripheral perfusion imaging
Dai, B., Babaei, S., Abbey, C. K., & Insana, M. F. (2022) · SPIE Medical Imaging: Ultrasonic Imaging and Tomography · doi:10.1117/12.2612640 · Cited by 2
Robust Super-Resolution Ultrasound Microbubble Tracking with Optical Flow Guided Kalman Filter
Pu, S.-L., Guo, H., Xie, H., & Zhou, G. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9958837 · Cited by 2
Erol, A., Generowicz, B. S., Kruizinga, P., & Hunyadi, B. (2023) · IEEE International Conference on Acoustics, Speech, and Signal Processing Workshops (ICASSPW) · doi:10.1109/icasspw59220.2023.10193574 · Cited by 2
Lemonnier, D., Mezghani, I., Theocharidis, G., Sumpio, B. J., Sia, S. K., Veves, A., & Chitnis, P. V. (2023) · IRBM · doi:10.1016/j.irbm.2023.100818 · Cited by 2
Ultrasound Flow Imaging Study on Rat Brain with Ultrasound and Light Stimulations
Zhang, J., Gong, C., Yang, Z., Wei, F., Sun, X. S., Ji, J., Zeng, Y., Chang, C.-F., Liu, X., Nair, D. S. R., et al. (2024) · Bioengineering · doi:10.3390/bioengineering11020174 · Cited by 2
Multi-Angle Emission and Cross-Correlation Based Ultrafast Doppler and Functional Ultrasound Imaging
Yan, S., Wu, H., & Xu, K. (2024) · IEEE UFFC Latin America Ultrasonics Symposium (LAUS) · doi:10.1109/laus60931.2024.10553202 · Cited by 2
Block-wise Independent Component Analysis for Slow Flow Non-Contrast Ultrasound Imaging
Weeks, A. E., Tierney, J. E., & Byram, B. C. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8926293 · Cited by 2
Side-viewing rotational IVUS imaging of slow flow with adaptive SVD filtering
Collins, G. C., Montemayor, N. P., Ozgun, K. A., Byram, B. C., & Lindsey, B. D. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251705 · Cited by 2
Apostolakis, I., Shin, J. S., Meral, F. C., Robert, J.-L., Sadeghi, A., & Vignon, F. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251578 · Cited by 2
Chinchilla, L., Frappart, T., Fraschini, C., Corréas, J.-M., & Gennisson, J. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593430 · Cited by 2
Self-citationImproved tendon tracking using singular value decomposition clutter suppression
Bandaru, R. S., Evers, S., Selles, R. W., Thoreson, A. R., Amadio, P. C., & Bosch, J. G. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8091643 · Cited by 2
Lin, H., Wang, Z., Liao, Y., Yu, Z., Xu, H., Qin, T. G., Tang, J., Yang, X., Chen, S., Zhang, X., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4794470 · Cited by 2
Opioid-Induced Inter-regional Dysconnectivity Correlates with Analgesia in Awake Mouse BrainsPreprint
Mariani, J.-C. R. P., Diebolt, S., Beynac, L., Santos, R., Schulz, S., Deffieux, T., Tanter, M., Lenkei, Z., & Kliewer, A. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.07.30.604249 · Cited by 2
Self-citationChen, Y., Zhao, S., Basu, S., Shi, J. F., Song, K., Siripun, P., Huynh, H., Zhao, Y., & Campbell, R. H. (2024) · Research Square · doi:10.21203/rs.3.rs-4754944/v1 · Cited by 2
Morris, M., Durie, E., Sinnett, V., Toulemonde, M. E. G., Roxanis, I., Allen, S. L., Downey, K., Scudder, J., Gagliardi, T. J., Scott-Mackie, P. L., et al. (2024) · medRxiv · doi:10.1101/2024.10.15.24315514 · Cited by 2
Miniaturized and accessible functional ultrasound imaging system for freely moving micePreprint
Yang, J., Zhou, E., Zhu, J., Zhu, T., Zhao, J., Lin, X., Cao, Z. H., Chen, Z., An, Z., Sun, L., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.24.650351 · Cited by 2
In vivo microcirculation mapping of human skin keloid by 40-MHz ultrafast ultrasound imaging
Chen, P., Hsueh, Y., & Huang, C. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8091991 · Cited by 1
Kortenbout, A. J., Costerus, S. A., Dudink, J., de Jong, N., de Graaff, J. C., Vos, H. J., & Bosch, J. G. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.12.006 · Cited by 1
Power-Doppler Ultrasonic Imaging of Peripheral Perfusion in Diabetic Mice
Babaei, S., Dobrucki, L. W., & Insana, M. F. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3373254 · Cited by 1
Wei, X., Wang, R., Huang, L., & Luo, J. (2024) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi56570.2024.10635348 · Cited by 1
Huang, Y., van Sloun, R. J. G., & Mischi, M. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108542 · Cited by 1
Total Variational Robust PCA for Ultrasound Microvascular Clutter Filtering
Fang, B., Li, H., & Chen, Y. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793489 · Cited by 1
Bergel, A., & Pouget, P. (2026) · Journal of Neurophysiology · doi:10.1152/jn.00610.2024 · Cited by 3
Self-citationShen, C.-C., & Lin, S.-D. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2024.12.006 · Cited by 1
Omnidirectional ultrasound tomographic vector flow imaging with a ring-array transducer
Jin, G., Javaherian, A., Yan, Y., & Mehrmohammadi, M. (2025) · SPIE Medical Imaging: Ultrasonic Imaging and Tomography · doi:10.1117/12.3047032 · Cited by 1
Ultrasound Doppler System's Resolution Using Coherent Plane-Wave Compounding Technique
Barannik, E. A., & Hrytsenko, M. O. (2025) · East European Journal of Physics · doi:10.26565/2312-4334-2025-1-43 · Cited by 1
Yu, H., Zhang, J., Feng, F., Yang, J., Xia, Y., Zhao, Y.-L., & Zhang, J. (2025) · Advanced Science · doi:10.1002/advs.202505485 · Cited by 1
Hierarchical encoding of natural sound mixtures in ferret auditory cortex
Landemard, A., Bimbard, C., & Boubenec, Y. (2025) · eLife · doi:10.7554/elife.106628.3 · Cited by 1
Unsupervised Unfolded rPCA Clutter Filtering
Li, H., Li, H., & Chen, Y. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201508 · Cited by 1
Metadata
- Authors
- Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., Cohen, I., Baud, O., & Tanter, M.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Inserm (FR)
- ORCID
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2015-11
- Volume
- 34
- Issue
- 11
- Pages
- 2271-2285
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2070712157
- Cited by
- 983
- References
- 39
- Citations by year
- 2026: 79 · 2025: 137 · 2024: 120 · 2023: 107 · 2022: 102 · 2021: 103 · 2020: 95 · 2019: 80 · 2018: 71 · 2017: 56 · 2016: 27 · 2015: 6
- FWCI
- 43.18
- Type
- journal article
- Language
- en
- Open access
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- HAL (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-10-IDEX-0001)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- ultrafast ultrasound imaging, clutter suppression, Doppler imaging, blood flow detection, tissue motion, microvascular networks, neonatal brain imaging
- MeSH terms
- Animals, Blood Flow Velocity, Echoencephalography, Humans, Image Processing, Computer-Assisted, Infant, Newborn, Kidney, Signal Processing, Computer-Assisted, Models, Statistical, Rats, Sprague-Dawley, Ultrasonography, Doppler, Phantoms, Imaging, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review