CoChat

Pulmonary Nodule Detection in CT Images: False Positive Reduction Using Multi-View Convolutional Networks

Open access
Setio, Arnaud Arindra Adiyoso, Ciompi, Francesco, Litjens, Geert, Gerke, Paul, Jacobs, Colin, van Riel, Sarah J., Wille, Mathilde Marie Winkler, Naqibullah, Matiullah, Sanchez, Clara I., van Ginneken, Bram · 2016 · IEEE Transactions on Medical Imaging

The DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index.

Abstract

We propose a novel Computer-Aided Detection (CAD) system for pulmonary nodules using multi-view convolutional networks (ConvNets), for which discriminative features are automatically learnt from the training data. The network is fed with nodule candidates obtained by combining three candidate detectors specifically designed for solid, subsolid, and large nodules. For each candidate, a set of 2-D patches from differently oriented planes is extracted. The proposed architecture comprises multiple streams of 2-D ConvNets, for which the outputs are combined using a dedicated fusion method to get the final classification. Data augmentation and dropout are applied to avoid overfitting. On 888 scans of the publicly available LIDC-IDRI dataset, our method reaches high detection sensitivities of 85.4% and 90.1% at 1 and 4 false positives per scan, respectively. An additional evaluation on independent datasets from the ANODE09 challenge and DLCST is performed. We showed that the proposed multi-view ConvNets is highly suited to be used for false positive reduction of a CAD system.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmi.2016.2536809

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 7

  1. tieleman, 2012, Lecture 6.5?RmsProp: Divide the gradient by a running average of its recent magnitude, COURSERA Neural Networks for Machine Learning
  2. cruz-roa, 2013, Medical Image Computing and Computer-Assisted Intervention, 8150, 403
  3. li, 2014, Medical Image Computing and Computer-Assisted Intervention, 8675, 305
  4. roth, 2014, Medical Image Computing and Computer-Assisted Intervention, 8673, 520
  5. brosch, 2014, Medical Image Computing and Computer-Assisted Intervention, 8674, 462
  6. 2014, Cancer Facts Figures 2014
  7. bergstra, 2010, Theano: A CPU and GPU math expression compiler, Proc Python Sci Comput Conf, 1

Cited by

See all 1,258

Metadata

Authors
Setio, A. A. A., Ciompi, F., Litjens, G., Gerke, P., Jacobs, C., van Riel, S. J., Wille, M. M. W., Naqibullah, M., Sanchez, C. I., & van Ginneken, B.
Affiliations
  • Radboud University Medical Center (NL)
  • Diagnostic Image Analysis Group at the Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
  • University of Copenhagen (DK)
Venue
IEEE Transactions on Medical Imaging
Published
2016-05
Volume
35
Issue
5
Pages
1160-1169
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2322371438
Cited by
1,258
References
45
Citations by year
2026: 67 · 2025: 71 · 2024: 89 · 2023: 137 · 2022: 140 · 2021: 186 · 2020: 158 · 2019: 193 · 2018: 132 · 2017: 72 · 2016: 13
FWCI
112.57
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed (publishedVersion)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
  • Radboud Repository (Radboud University) (submittedVersion, other-oa)
Funders
The Netherlands Organization for Scientific Research (639.023.207)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
lung nodule detection, computer-aided detection, false positive reduction, multi-stream feature fusion, solid nodules, subsolid nodules, LIDC-IDRI
MeSH terms
Machine Learning, Algorithms, Solitary Pulmonary Nodule, Humans, Lung Neoplasms, Pattern Recognition, Automated, Radiographic Image Interpretation, Computer-Assisted, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.