Automatic Quality Assessment of Echocardiograms Using Convolutional Neural Networks: Feasibility on the Apical Four-Chamber View
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Echocardiography (echo) is a skilled technical procedure that depends on the experience of the operator. The aim of this paper is to reduce user variability in data acquisition by automatically computing a score of echo quality for operator feedback. To do this, a deep convolutional neural network model, trained on a large set of samples, was developed for scoring apical four-chamber (A4C) echo. In this paper, 6,916 end-systolic echo images were manually studied by an expert cardiologist and were assigned a score between 0 (not acceptable) and 5 (excellent). The images were divided into two independent training-validation and test sets. The network architecture and its parameters were based on the stochastic approach of the particle swarm optimization on the training-validation data. The mean absolute error between the scores from the ultimately trained model and the expert's manual scores was 0.71 ± 0.58. The reported error was comparable to the measured intra-rater reliability. The learned features of the network were visually interpretable and could be mapped to the anatomy of the heart in the A4C echo, giving confidence in the training result. The computation time for the proposed network architecture, running on a graphics processing unit, was less than 10 ms per frame, sufficient for real-time deployment. The proposed approach has the potential to facilitate the widespread use of echo at the point-of-care and enable early and timely diagnosis and treatment. Finally, the approach did not use any specific assumptions about the A4C echo, so it could be generalizable to other standard echo views.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Backpropagation Applied to Handwritten Zip Code Recognition
LeCun, Y., Boser, B., Denker, J. S., Henderson, D., Howard, R. E., Hubbard, W., & Jackel, L. D. (1989) · Neural Computation · doi:10.1162/neco.1989.1.4.541 · Cited by 11,891
Recent advances in convolutional neural networks
Gu, J., Wang, Z., Kuen, J., Ma, L., Shahroudy, A., Shuai, B., Liu, T., Wang, X., Wang, G., Cai, J., et al. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2017.10.013 · Cited by 6,576
Improving neural networks by preventing co-adaptation of feature detectors
Hinton, G. E., Srivastava, N., Krizhevsky, A., Sutskever, I., & Salakhutdinov, R. R. (2012) · arXiv · doi:10.48550/arxiv.1207.0580 · Cited by 6,382 · cited 1×
“Dropout layers (dropout) prevent co-adaptation of feature extractors and encourage neurons to follow the population behavior [36].”
Background
Cited by
Convolutional Neural Networks for Radiologic Images: A Radiologist’s Guide
Soffer, S., Ben-Cohen, A., Shimon, O., Amitai, M. M., Greenspan, H., & Klang, E. (2019) · Radiology · doi:10.1148/radiol.2018180547 · Cited by 577
Mazurowski, M. A., Buda, M., Saha, A., & Bashir, M. R. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26534 · Cited by 554
State-of-the-Art Deep Learning in Cardiovascular Image Analysis
Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.06.009 · Cited by 388
DiPietro, R., & Hager, G. D. (2020) · Handbook of Medical Image Computing and Computer Assisted Intervention · doi:10.1016/b978-0-12-816176-0.00026-0 · Cited by 293
A Generic Quality Control Framework for Fetal Ultrasound Cardiac Four-Chamber Planes
Dong, J., Liu, S., Liao, Y., Wen, H., Lei, B., Li, S., & Wang, T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2948316 · Cited by 104
Metadata
- Authors
- Abdi, A. H., Luong, C., Tsang, T., Allan, G., Nouranian, S., Jue, J., Hawley, D., Fleming, S., Gin, K., Swift, J., Rohling, R., & Abolmaesumi, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2017-06
- Volume
- 36
- Issue
- 6
- Pages
- 1221-1230
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2605159090
- Cited by
- 137
- References
- 5
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.