The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation
Open accessAbstract
Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods segment them separately, and rely on hand-crafted visual feature from fundus images. In this paper, we propose a deep learning architecture, named M-Net, which solves the OD and OC segmentation jointly in a one-stage multi-label system. The proposed M-Net mainly consists of multi-scale input layer, U-shape convolutional network, side-output layer, and multi-label loss function. The multi-scale input layer constructs an image pyramid to achieve multiple level receptive field sizes. The U-shape convolutional network is employed as the main body network structure to learn the rich hierarchical representation, while the side-output layer acts as an early classifier that produces a companion local prediction map for different scale layers. Finally, a multi-label loss function is proposed to generate the final segmentation map. For improving the segmentation performance further, we also introduce the polar transformation, which provides the representation of the original image in the polar coordinate system. The experiments show that our M-Net system achieves state-of-the-art OD and OC segmentation result on ORIGA data set. Simultaneously, the proposed method also obtains the satisfactory glaucoma screening performances with calculated CDR value on both ORIGA and SCES datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Fully convolutional networks for semantic segmentation
Shelhamer, E., Long, J., & Darrell, T. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2572683 · Cited by 11,898
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040
Tham, Y.-C., Li, X., Wong, T. Y., Quigley, H. A., Aung, T., & Cheng, C.-Y. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.05.013 · Cited by 7,159
Richer Convolutional Features for Edge Detection
Liu, Y., Cheng, M.-M., Hu, X., Wang, K., & Bai, X. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.622 · Cited by 780
Generalized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776 · cited 1×
“Dice coefficient is a measure of overlap widely used to assess segmentation performance when the ground truth is available [35].”
MethodSuperpixel Classification Based Optic Disc and Optic Cup Segmentation for Glaucoma Screening
Cheng, J., Liu, J., Xu, Y., Yin, F., Wong, D. W. K., Tan, N.-M., Tao, D., Cheng, C.-Y., Aung, T., & Wong, T. Y. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2247770 · Cited by 593
Self-citationAquino, A., Gegúndez-Arias, M. E., & Marín, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053042 · Cited by 516
DeepVessel: Retinal Vessel Segmentation via Deep Learning and Conditional Random Field
Fu, H., Xu, Y., Lin, S., Kee Wong, D. W., & Liu, J. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_16 · Cited by 453
Self-citationSevastopolsky, A. (2017) · Pattern Recognition and Image Analysis · doi:10.1134/s1054661817030269 · Cited by 432
Optic Disk and Cup Segmentation From Monocular Color Retinal Images for Glaucoma Assessment
Joshi, G. D., Sivaswamy, J., & Krishnadas, S. R. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2106509 · Cited by 412
Visual Saliency Detection Based on Multiscale Deep CNN Features
Li, G., & Yu, Y. (2016) · IEEE Transactions on Image Processing · doi:10.1109/tip.2016.2602079 · Cited by 394
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., Fletcher, E., & Kennedy, L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823261 · Cited by 389
Zilly, J., Buhmann, J. M., & Mahapatra, D. (2017) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2016.07.012 · Cited by 372
Retinal layer segmentation of macular OCT images using boundary classification
Lang, A., Carass, A., Hauser, M., Sotirchos, E. S., Calabresi, P. A., Ying, H. S., & Prince, J. L. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001133 · Cited by 310
Deep Retinal Image Understanding
Maninis, K.-K., Pont-Tuset, J., Arbeláez, P., & Van Gool, L. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_17 · Cited by 305
Retinal vessel segmentation via deep learning network and fully-connected conditional random fields
Fu, H., Xu, Y., Wong, D. W. K., & Liu, J. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493362 · Cited by 274
Self-citationAbra`moff, M. D., Alward, W. L. M., Greenlee, E. C., Shuba, L., Kim, C. Y., Fingert, J. H., & Kwon, Y. H. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-1081 · Cited by 236
Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey
Almazroa, A., Burman, R., Raahemifar, K., & Lakshminarayanan, V. (2015) · Journal of Ophthalmology · doi:10.1155/2015/180972 · Cited by 234
Optic disk feature extraction via modified deformable model technique for glaucoma analysis
Xu, J., Chutatape., O., Sung, E., Zheng, C., & Kuan, P. C. T. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2006.10.015 · Cited by 185
Level-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI
Wong, D. W. K., Liu, J., Lim, J. H., Jia, X., Yin, F., Li, H., & Wong, T. Y. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649648 · Cited by 171
Self-citationAutomatic Feature Learning for Glaucoma Detection Based on Deep Learning
Chen, X., Xu, Y., Yan, S., Wong, D. W. K., Wong, T. Y., & Liu, J. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_80 · Cited by 160
Self-citationQuantitative evaluation of the optic nerve head in early glaucoma
Garway‐Heath, D. F., & Hitchings, R. A. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.4.352 · Cited by 120
Segmentation and Quantification for Angle-Closure Glaucoma Assessment in Anterior Segment OCT
Fu, H., Xu, Y., Lin, S., Zhang, X., Wong, D. W. K., Liu, J., Frangi, A. F., Baskaran, M., & Aung, T. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2703147 · Cited by 108
Self-citationOptic Disc and Cup Segmentation from Color Fundus Photograph Using Graph Cut with Priors
Zheng, Y., Stambolian, D. E., O’Brien, J. M., & Gee, J. C. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40763-5_10 · Cited by 81
Automated detection of kinks from blood vessels for optic cup segmentation in retinal images
Wong, D. W. K., Liu, J., Lim, J., Li, H., & Wong, T. Y. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.810784 · Cited by 77
Self-citationWu, M., Leng, T., de Sisternes, L., Rubin, D. L., & Chen, Q. (2015) · Optics Express · doi:10.1364/oe.23.031216 · Cited by 27
Similarity regularized sparse group lasso for cup to disc ratio computation
Cheng, J. T., Zhang, Z. D., Tao, D., Wong, D. W. K., Liu, J., Baskaran, M., Aung, T., & Wong, T. Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.003763 · Cited by 24
Self-citation
Cited by
CE-Net: Context Encoder Network for 2D Medical Image Segmentation
Gu, Z., Cheng, J., Fu, H., Zhou, K., Hao, H., Zhao, Y., Zhang, T., Gao, S., & Liu, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2903562 · Cited by 2,267
Self-citationInf-Net: Automatic COVID-19 Lung Infection Segmentation From CT Images
Fan, D.-P., Zhou, T., Ji, G.-P., Zhou, Y., Chen, G., Fu, H., Shen, J., & Shao, L. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2996645 · Cited by 1,259
Self-citationEmbracing imperfect datasets: A review of deep learning solutions for medical image segmentation
Tajbakhsh, N., Jeyaseelan, L., Li, Q., Chiang, J. N., Wu, Z., & Ding, X. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101693 · Cited by 1,095
Medical Image Segmentation Review: The Success of U-Net
Azad, R., Aghdam, E. K., Rauland, A., Jia, Y., Avval, A. H., Bozorgpour, A., Karimijafarbigloo, S., Cohen, J. P., Adeli, E., & Merhof, D. (2024) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2024.3435571 · Cited by 1,022
Medical image segmentation using deep learning: A survey
Wang, R., Lei, T., Cui, R., Zhang, B., Meng, H., & Nandi, A. K. (2022) · IET Image Processing · doi:10.1049/ipr2.12419 · Cited by 892
Metadata
- Authors
- Fu, H., Cheng, J., Xu, Y., Wong, D. W. K., Liu, J., & Cao, X.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2018-07
- Volume
- 37
- Issue
- 7
- Pages
- 1597-1605
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2782364420
- Cited by
- 834
- References
- 28
- FWCI
- 47.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.