Automated Radiographic Report Generation Purely on Transformer: A Multicriteria Supervised Approach
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Automated radiographic report generation is challenging in at least two aspects. First, medical images are very similar to each other and the visual differences of clinic importance are often fine-grained. Second, the disease-related words may be submerged by many similar sentences describing the common content of the images, causing the abnormal to be misinterpreted as the normal in the worst case. To tackle these challenges, this paper proposes a pure transformer-based framework to jointly enforce better visual-textual alignment, multi-label diagnostic classification, and word importance weighting, to facilitate report generation. To the best of our knowledge, this is the first pure transformer-based framework for medical report generation, which enjoys the capacity of transformer in learning long range dependencies for both image regions and sentence words. Specifically, for the first challenge, we design a novel mechanism to embed an auxiliary image-text matching objective into the transformer's encoder-decoder structure, so that better correlated image and text features could be learned to help a report to discriminate similar images. For the second challenge, we integrate an additional multi-label classification task into our framework to guide the model in making correct diagnostic predictions. Also, a term-weighting scheme is proposed to reflect the importance of words for training so that our model would not miss key discriminative information. Our work achieves promising performance over the state-of-the-arts on two benchmark datasets, including the largest dataset MIMIC-CXR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks
Ren, S., He, K., Girshick, R., & Sun, J. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2577031 · Cited by 73,472
BERT: Pre-training of Deep Bidirectional Transformers for Language Understanding
Devlin, J., Chang, M.-W., Lee, K., & Toutanova, K. (2019) · Proceedings of the 2019 Conference of the North American Chapter of the Association for Computational Linguistics: Human Language Technologies, Volume 1 (Long and Short Papers) · doi:10.18653/v1/n19-1423 · Cited by 54,325
End-to-End Object Detection with Transformers
Carion, N., Massa, F., Synnaeve, G., Usunier, N., Kirillov, A., & Zagoruyko, S. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-58452-8_13 · Cited by 18,285
End-to-End Object Detection with Transformers
Carion, N., Massa, F., Synnaeve, G., Usunier, N., Kirillov, A., & Zagoruyko, S. (2020) · arXiv · doi:10.48550/arxiv.2005.12872 · Cited by 18,253 · cited 1×
“Although transforms are increasingly used in vision tasks such as image classi-fication [9] and object detection [10], pure transformer-based visual encoder (without CNN) has not been well studied for image captioning.”
MethodShow and tell: A neural image caption generator
Vinyals, O., Toshev, A., Bengio, S., & Erhan, D. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298935 · Cited by 6,318
Long-term recurrent convolutional networks for visual recognition and description
Donahue, J., Hendricks, L. A., Guadarrama, S., Rohrbach, M., Venugopalan, S., Darrell, T., & Saenko, K. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298878 · Cited by 5,228
Deep visual-semantic alignments for generating image descriptions
Karpathy, A., & Fei-Fei, L. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298932 · Cited by 4,902
CIDEr: Consensus-based image description evaluation
Vedantam, R., Zitnick, C. L., & Parikh, D. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7299087 · Cited by 4,845
Cited by
METransformer: Radiology Report Generation by Transformer with Multiple Learnable Expert Tokens
Wang, Z., Liu, L., Wang, L., & Zhou, L. (2023) · 2023 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52729.2023.01112 · Cited by 184
“To further improve performance, some works [4, 5, 33] employ a transformer instead of LSTM as the report decoder, which has achieved good results.”
MethodSelf-citationBaker, S., & Xiang, W. (2023) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2023.3256323 · Cited by 178
“In healthcare, vision-language transformers have primarily been explored for generating radiology reports [162] and describing pathology images [163].”
BackgroundMulti-task paired masking with alignment modeling for medical vision-language pre-training
Zhang, K., Yang, Y., Yu, J., Jiang, H., Fan, J., Huang, Q., & Han, W. (2024) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2023.3325965 · Cited by 51
“, Clinical-BERT [25] and non-pretraining SOTA methods such as R2Gen [18], R2GenCMN [19], PPKED [20], AlignTrans [21], CMM+RL [22], RAMTU [23], and Multi-Criteria [24].”
MethodStyle-Aware Radiology Report Generation with RadGraph and Few-Shot Prompting
Yan, B., Liu, R., Kuo, D., Adithan, S., Reis, E., Kwak, S., Venugopal, V., O’Connell, C., Saenz, A., Rajpurkar, P., et al. (2023) · Findings of the Association for Computational Linguistics: EMNLP 2023 · doi:10.18653/v1/2023.findings-emnlp.977 · Cited by 22
ALGAN: Time Series Anomaly Detection with Adjusted-LSTM GAN
Bashar, M. A., & Nayak, R. (2023) · doi:10.21203/rs.3.rs-3609809/v1 · Cited by 22
Metadata
- Authors
- Wang, Z., Han, H., Wang, L., Li, X., & Zhou, L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2022-10
- Volume
- 41
- Issue
- 10
- Pages
- 2803-2813
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W4229027955
- Cited by
- 108
- References
- 21
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.