Learn2Reg: Comprehensive Multi-Task Medical Image Registration Challenge, Dataset and Evaluation in the Era of Deep Learning
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Image registration is a fundamental medical image analysis task, and a wide variety of approaches have been proposed. However, only a few studies have comprehensively compared medical image registration approaches on a wide range of clinically relevant tasks. This limits the development of registration methods, the adoption of research advances into practice, and a fair benchmark across competing approaches. The Learn2Reg challenge addresses these limitations by providing a multi-task medical image registration data set for comprehensive characterisation of deformable registration algorithms. A continuous evaluation will be possible at https:// learn2reg.grand-challenge.org. Learn2Reg covers a wide range of anatomies (brain, abdomen, and thorax), modalities (ultrasound, CT, MR), availability of annotations, as well as intra- and inter-patient registration evaluation. We established an easily accessible framework for training and validation of 3D registration methods, which enabled the compilation of results of over 65 individual method submissions from more than 20 unique teams. We used a complementary set of metrics, including robustness, accuracy, plausibility, and runtime, enabling unique insight into the current state-of-the-art of medical image registration. This paper describes datasets, tasks, evaluation methods and results of the challenge, as well as results of further analysis of transferability to new datasets, the importance of label supervision, and resulting bias. While no single approach worked best across all tasks, many methodological aspects could be identified that push the performance of medical image registration to new state-of-the-art performance. Furthermore, we demystified the common belief that conventional registration methods have to be much slower than deep-learning-based methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526 · cited 1×
“Semi-automatic labels with manual corrections of 35 cortical and subcortical brain structures were generated using FreeSurfer [31].”
MethodThe Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599 · cited 2×
“Abdomen MR-CT : The data was compiled from public studies of the cancer imaging archive (TCIA) [23] that contained paired scans of both MR and CT from the same patients.”
BackgroundElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 6×
“The method is implemented within the Elastix framework.”
MethodInfluentialSelf-citationPWC-Net: CNNs for Optical Flow Using Pyramid, Warping, and Cost Volume
Sun, D., Yang, X., Liu, M.-Y., & Kautz, J. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00931 · Cited by 2,648
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227 · cited 1×
“head MR (T1, T2), PET and CT, there have been several brain registration benchmarks - most notably the evaluation of 14 nonlinear iterative registration algorithms [11].”
BackgroundMarcus, D. S., Wang, T. H., Parker, J., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.9.1498 · Cited by 2,163
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587 · cited 2×
“3) Survey Papers and Baseline Methods: Surveys on conventional medical image registration [2], [3] have comprehensively reviewed typical categories of approaches including similarity metric, regulariser, and optimiser criteria.”
BackgroundThe Medical Segmentation Decathlon
Antonelli, M., Reinke, A., Bakas, S., Farahani, K., Kopp-Schneider, A., Landman, B. A., Litjens, G., Menze, B., Ronneberger, O., Summers, R. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-30695-9 · Cited by 1,384 · cited 1×
“Previous to the Learn2Reg challenge, the dataset was used as part of the Medical Segmentation Decathlon [22].”
MethodSelf-citationDeep learning in medical image registration: a survey
Haskins, G., Kruger, U., & Yan, P. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01060-x · Cited by 704 · cited 1×
“IMAGE registration is a fundamental task in medical image analysis and has been an active field of research for decades [1], [2], [3], [4].”
BackgroundUnsupervised Learning of Probabilistic Diffeomorphic Registration for Images and Surfaces
Dalca, A. V., Balakrishnan, G., Guttag, J., & Sabuncu, M. R. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.07.006 · Cited by 467 · cited 1×
“While few papers have evaluated their proposed registration method on more than two different registration tasks, there is a variety of public methods SyN [14], Elastix [15], NiftyReg [16] and deeds [17], and Voxelmorph [18] that are commonly used as baseline or comparison methods.”
MethodSelf-citation
Cited by
TransMorph: Transformer for unsupervised medical image registration
Chen, J., Frey, E. C., He, Y., Segars, W. P., Li, Y., & Du, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102615 · Cited by 804
Metadata
- Authors
- Hering, A., Hansen, L., Mok, T. C. W., Chung, A. C. S., Siebert, H., Hager, S., Lange, A., Kuckertz, S., Heldmann, S., Shao, W., Vesal, S., Rusu, M., Sonn, G., Estienne, T., Vakalopoulou, M., Han, L., Huang, Y., Yap, P.-T., Brudfors, M., Balbastre, Y., Joutard, S., Modat, M., Lifshitz, G., Raviv, D., Lv, J., Li, Q., Jaouen, V., Visvikis, D., Fourcade, C., Rubeaux, M., Pan, W., Xu, Z., Jian, B., De Benetti, F., Wodzinski, M., Gunnarsson, N., Sjolund, J., Grzech, D., Qiu, H., Li, Z., Thorley, A., Duan, J., Grosbrohmer, C., Hoopes, A., Reinertsen, I., Xiao, Y., Landman, B., Huo, Y., Murphy, K., Lessmann, N., van Ginneken, B., Dalca, A. V., & Heinrich, M. P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2023-03
- Volume
- 42
- Issue
- 3
- Pages
- 697-712
- ISSN
- 0278-0062
- 1558-254X
- OpenAlex
- W4306914348
- Cited by
- 250
- References
- 11
- FWCI
- 27.06
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.