Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 500

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

UNETR++: Delving Into Efficient and Accurate 3D Medical Image Segmentation

Open access
Shaker, Abdelrahman, Maaz, Muhammad, Rasheed, Hanoona, Khan, Salman, Yang, Ming-Hsuan, Shahbaz Khan, Fahad · 2024 · IEEE Transactions on Medical Imaging

Abstract

Owing to the success of transformer models, recent works study their applicability in 3D medical segmentation tasks. Within the transformer models, the self-attention mechanism is one of the main building blocks that strives to capture long-range dependencies, compared to the local convolutional-based design. However, the self-attention operation has quadratic complexity which proves to be a computational bottleneck, especially in volumetric medical imaging, where the inputs are 3D with numerous slices. In this paper, we propose a 3D medical image segmentation approach, named UNETR++, that offers both high-quality segmentation masks as well as efficiency in terms of parameters, compute cost, and inference speed. The core of our design is the introduction of a novel efficient paired attention (EPA) block that efficiently learns spatial and channel-wise discriminative features using a pair of inter-dependent branches based on spatial and channel attention. Our spatial attention formulation is efficient and has linear complexity with respect to the input. To enable communication between spatial and channel-focused branches, we share the weights of query and key mapping functions that provide a complimentary benefit (paired attention), while also reducing the complexity. Our extensive evaluations on five benchmarks, Synapse, BTCV, ACDC, BraTS, and Decathlon-Lung, reveal the effectiveness of our contributions in terms of both efficiency and accuracy. On Synapse, our UNETR++ sets a new state-of-the-art with a Dice Score of 87.2%, while significantly reducing parameters and FLOPs by over 71%, compared to the best method in the literature. Our code and models are available at: https://tinyurl.com/2p87x5xn.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2024.3398728

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 48 references

Cited by

See all 500

Metadata

Authors
Shaker, A., Maaz, M., Rasheed, H., Khan, S., Yang, M.-H., & Shahbaz Khan, F.
Venue
IEEE Transactions on Medical Imaging
Published
2024-09
Volume
43
Issue
9
Pages
3377-3390
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W4396783545
Cited by
500
References
48
FWCI
68.37
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: UNETR++: Delving Into Efficient and Accurate 3D Medical Image Segmentation. https://app.cochat.ai/papers/10.1109/tmi.2024.3398728
The paper
Shaker, A., Maaz, M., Rasheed, H., Khan, S., Yang, M.-H., & Shahbaz Khan, F. (2024). UNETR++: Delving Into Efficient and Accurate 3D Medical Image Segmentation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2024.3398728

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.