The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Autonomy for Surgical Robots: Concepts and Paradigms
Abstract
Robot-assisted and computer-integrated surgery provides innovative, minimally invasive solutions to heal complex injuries and diseases. The dominant portion of these surgical interventions has been performed with master-slave teleoperation systems, which are not capable of autonomous task execution or cognitive decision making. Much of the most advanced technologies foundered on the drawing boards or at the research labs for a long time, partially due to the fact that the surgical domain is resistant to the introduction of new hazards via the increased complexity of novel solutions. It has been seen with similar heavily regulated areas that internationally accepted standards can facilitate the adoption of new technologies in a safe manner. This paper reviews the existing autonomous capabilities of surgical robots, and investigates the major barriers of development presented by the lack of autonomy benchmarks and standards. The emerging safety standard environment is presented, as a key enabling factor to the commercialization of autonomous surgical robots. A practical scale is introduced to assess the level of autonomy of current and future surgical robots. Regarding the forthcoming robotic platforms, it is crucial to improve the transparency of the regulatory environment, streamline the standardization framework, and increase the social acceptance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deo, R. C. (2015) · Circulation · doi:10.1161/circulationaha.115.001593 · Cited by 3,466
Micro/nanorobots for biomedicine: Delivery, surgery, sensing, and detoxification
Li, J., Esteban-Fernández de Ávila, B., Gao, W., Zhang, L., & Wang, J. (2017) · Science Robotics · doi:10.1126/scirobotics.aam6431 · Cited by 1,565
Kaber, D. B., & Endsley, M. R. (2004) · Theoretical Issues in Ergonomics Science · doi:10.1080/1463922021000054335 · Cited by 789
Medical robotics—Regulatory, ethical, and legal considerations for increasing levels of autonomy
Yang, G.-Z., Cambias, J., Cleary, K., Daimler, E., Drake, J., Dupont, P. E., Hata, N., Kazanzides, P., Martel, S., Patel, R. V., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aam8638 · Cited by 741
Supervised autonomous robotic soft tissue surgery
Shademan, A., Decker, R. S., Opfermann, J. D., Leonard, S., Krieger, A., & Kim, P. C. W. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad9398 · Cited by 620
Surgical data science for next-generation interventions
Maier-Hein, L., Vedula, S. S., Speidel, S., Navab, N., Kikinis, R., Park, A., Eisenmann, M., Feussner, H., Forestier, G., Giannarou, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0132-7 · Cited by 566
PLUS: Open-Source Toolkit for Ultrasound-Guided Intervention Systems
Lassó, A., Heffter, T., Rankin, A., Pintér, C., Ungi, T., & Gabor Fichtinger, A. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2322864 · Cited by 421
A consensus document on robotic surgery
The SAGES-MIRA Robotic Surgery Consensus Group, Herron, D. M., & Marohn, M. (2008) · Surgical Endoscopy · doi:10.1007/s00464-007-9727-5 · Cited by 421
An image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Cited by
Autonomous robotic laparoscopic surgery for intestinal anastomosis
Saeidi, H., Opfermann, J. D., Kam, M., Wei, S., Leonard, S., Hsieh, M. H., Kang, J. U., & Krieger, A. (2022) · Science Robotics · doi:10.1126/scirobotics.abj2908 · Cited by 384
Attanasio, A., Scaglioni, B., De Momi, E., Fiorini, P., & Valdastri, P. (2021) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-062420-090543 · Cited by 263
Levels of autonomy in FDA-cleared surgical robots: a systematic review
Lee, A., Baker, T. S., Bederson, J. B., & Rapoport, B. I. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01102-y · Cited by 172
Designing robots that do no harm: understanding the challenges of Ethics for Robots
Hutler, B., Rieder, T. N., Mathews, D. J. H., Handelman, D. A., & Greenberg, A. M. (2024) · AI and Ethics · doi:10.1007/s43681-023-00283-8 · Cited by 16
(2021) · doi:10.1145/3461778.3461997 · Cited by 14
“, search-and-rescue operation [24], autonomous driving [35], surgery [23], recreational and service robot [41]).”
Background
Metadata
- Authors
- Haidegger, T.
- Venue
- IEEE Transactions on Medical Robotics and Bionics
- Published
- 2019-05
- Volume
- 1
- Issue
- 2
- Pages
- 65-76
- ISSN
- 2576-3202 (ISSN-L)
- OpenAlex
- W2941276819
- Cited by
- 306
- References
- 41
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.