Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Artificial Pancreas: In Silico Study Shows No Need of Meal Announcement and Improved Time in Range of Glucose With Intraperitoneal vs. Subcutaneous Insulin Delivery

Open access
Toffanin, Chiara, Magni, Lalo, Cobelli, Claudio · 2021 · IEEE Transactions on Medical Robotics and Bionics

Abstract

Contemporary Artificial Pancreas (AP) consists of a subcutaneous (SC) glucose sensor, a SC insulin pump and a control algorithm. Even the most advanced systems are far from optimal, in particular due to the non-physiologic nature of SC route. While SC insulin delivery is convenient and minimally invasive, it introduces delays to insulin action that make tight control difficult, particularly during meals. In addition frequent patient interventions are needed, e.g., at mealtime. The intraperitoneal (IP) insulin delivery could address this major challenge since it exhibits a faster pharmacokinetics/pharmacodynamics, hence making easier to quickly respond to glycemic disturbances. A 1-day hospital closed-loop study has shown significant improvements of IP glucose control vs SC AP, and that meal announcement is not necessary. However, the IP AP has not been tested in more realistic everyday life conditions. In this work we have performed an in silico study of 14 days of an IP AP by using the UVA/Padova simulator which includes intra- and inter-day variability of insulin sensitivity and several real life scenarios. We show superiority of IP AP vs SC AP in terms of quality of glucose control (time in range 87% IP vs 80% SC) without the need of a meal announcement.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmrb.2021.3075775

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 49 references

Research works printed but not linked: 1

  1. 2017, IDF Diabetes Atlas Eighth Edition

Cited by

See all 22

Metadata

Authors
Toffanin, C., Magni, L., & Cobelli, C.
Affiliations
  • University of Pavia (IT)
  • University of Padua (IT)
Venue
IEEE Transactions on Medical Robotics and Bionics
Published
2021-05
Volume
3
Issue
2
Pages
306-314
ISSN
2576-3202 (ISSN-L)
OpenAlex
W3157871157
Cited by
22
References
49
Citations by year
2025: 3 · 2024: 4 · 2023: 8 · 2022: 6 · 2021: 1
FWCI
3.55
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Medical Robotics and Bionics (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion, other-oa)
Funders
  • Italian Project PRIN15: “Forget Diabetes: Adaptive Physiological Artificial Pancreas”
  • H2020-FETPROACT Project FORGETDIABETS (951933)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
artificial pancreas, subcutaneous insulin administration, time in range, glycemic control, computer simulation, UVA/Padova simulator

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Pancreas: In Silico Study Shows No Need of Meal Announcement and Improved Time in Range of Glucose With Intraperitoneal vs. Subcutaneous Insulin Delivery. https://app.cochat.ai/papers/10.1109/tmrb.2021.3075775
The paper
Toffanin, C., Magni, L., & Cobelli, C. (2021). Artificial Pancreas: In Silico Study Shows No Need of Meal Announcement and Improved Time in Range of Glucose With Intraperitoneal vs. Subcutaneous Insulin Delivery. IEEE Transactions on Medical Robotics and Bionics. https://doi.org/10.1109/tmrb.2021.3075775

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.