Dielectric Measurements of Millimeter-Wave Materials
The DOI matches its Crossref record.
Abstract
It is no longer necessary to use extrapolated microwave dielectric data when designing millimeter-wave components, devices, and systems. Precision measurements can now be made to generate highly accurate millimeter-wave (5 to 1/2 mm) continuous spectra on complex refractive index, complex dielectric permittivity, and loss tangent for a variety of materials such as common ceramics, semiconductors, crystalline, and glassy materials. The continuous spectra reveal an increase in dielectric loss with increase in frequency in this wavelength range for most materials. Reliable measurements also reveal that the method of preparation of nominally identical specimens can change the dielectric losses by many factors. These broad-band measurements were carried out employing dispersive Fourier transform spectroscopy applied to a modular two-beam polarization interferometer. Data obtained with Fabry-Perot open resonator methods at wavelengths of 5 mm and longer will also be compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Dai, J., Zhang, J., Zhang, W., & Grischkowsky, D. (2004) · Journal of the Optical Society of America B · doi:10.1364/josab.21.001379 · Cited by 499
“From equations (6), it is clear that if the quantities LnuU2(v)/U1(v)u, LnuU3(v)/U1(v)u, and LnuU3(v)/U2(v)u are negative, indicating that the transfer function for the reference pulse is closer to unity than that of the signal pulse, the measured absorption coefficients a21(v), a31(v), and a32(v) will be upper limits…”
BackgroundHighly accurate optical material parameter determination with THz time-domain spectroscopy
Pupeza, I., Wilk, R., & Koch, M. (2007) · Optics Express · doi:10.1364/oe.15.004335 · Cited by 351
Miscellaneous data on materials for millimetre and submillimetre optics
Lamb, J. W. (1996) · International Journal of Infrared and Millimeter Waves · doi:10.1007/bf02069487 · Cited by 349
Bolivar, P. H., Brucherseifer, M., Rivas, J. G., Gonzalo, R., Ederra, I., Reynolds, A. L., Holker, M., & de Maagt, P. (2003) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2003.809693 · Cited by 220
“7 shows measurements performed on high-resistivity crystalline silicon (epsilon ), which, despite of a higher cost, is known to be an excellent dielectric material at terahertz frequencies [15]–[17].”
BackgroundResultDielectric characterization of low-loss materials a comparison of techniques
Baker-Jarvis, J., Geyer, R. G., Grosvenor, J. H., Janezic, M. D., Jones, C. A., Riddle, B., Weil, C. M., & Krupka, J. (1998) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.708274 · Cited by 212
Khan, U. A., Nguyen, N., & Afsar, M. N. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.909601 · Cited by 21
Self-citationCarnio, B. N., Moutanabbir, O., & Elezzabi, A. Y. (2023) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-023-00946-x
Metadata
- Authors
- Afsar, M. N.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 1984-12
- Volume
- 32
- Issue
- 12
- Pages
- 1598-1609
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W1967381921
- Cited by
- 153
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.