The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Range Correlation and<tex>$ I/ Q$</tex>Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary Monitoring
Abstract
Direct-conversion microwave Doppler-radar transceivers have been fully integrated in 0.25-/spl mu/m silicon CMOS and BiCMOS technologies. These chips, operating at 1.6 and 2.4 GHz, have detected movement due to heartbeat and respiration 50 cm from the subject, which may be useful in infant and adult apnea monitoring. The range-correlation effect on residual phase noise is a critical factor when detecting small phase fluctuations with a high-phase-noise on-chip oscillator. Phase-noise reduction due to range correlation was experimentally evaluated, and the measured residual phase noise was within 5 dB of predicted values on average. In a direct-conversion receiver, the phase relationship between the received signal and the local oscillator has a significant effect on the demodulation sensitivity, and the null points can be avoided with a quadrature (I/Q) receiver. In this paper, measurements that highlight the performance benefits of an I/Q receiver are presented. While the accuracy of the heart rate measured with the single-channel chip ranges from 40% to 100%, depending on positioning, the quadrature chip accuracy is always better than 80%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R., Millman, R., Coppola, M., Fleetham, J., Murray, C. F., Iber, C., McCall, W. V., Nino-Murcia, G., Pressman, M., Sanders, M., et al. (1994) · Sleep · doi:10.1093/sleep/17.4.378 · Cited by 433
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299
Self-citationA microwave radio for Doppler radar sensing of vital signs
Droitcour, A., Lubecke, V., Lin, J., & Boric-Lubecke, O. (2002) · 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157) · doi:10.1109/mwsym.2001.966866 · Cited by 252
Self-citationVgontzas, M., & Kales, M. (1999) · Annual Review of Medicine · doi:10.1146/annurev.med.50.1.387 · Cited by 227
Heart rate monitors: State of the art
Laukkanen, R. M. T., & Virtanen, P. K. (1998) · Journal of Sports Sciences · doi:10.1080/026404198366623 · Cited by 218
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R. A., Millman, R. P., Coppola, M. P., Fleetham, J. A., Murray, C. F., Iber, C., McCall, W. V., Nino‐Murcia, G., Pressman, M. R., SANDERS, M. H., et al. (2018) · SLEEP · doi:10.1093/sleep/zsy134 · Cited by 152
Annual Summary of Vital Statistics: 2000
Hoyert, D. L., Freedman, M. A., Strobino, D. M., & Guyer, B. (2001) · PEDIATRICS · doi:10.1542/peds.108.6.1241 · Cited by 147
A digital signal processor for Doppler radar sensing of vital signs
Lohman, B., Borić-Lubecke, O., Lubecke, V. M., Ong, P. W., & Sondhi, M. M. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1044188 · Cited by 107
Self-citationDroitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., & Lin, J. (2003) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2002.993075 · Cited by 105
Self-citationRange correlation effects on phase and amplitude noise
Budge, M. C., & Burt, M. P. (2002) · IEEE SoutheastCon · doi:10.1109/secon.1993.465731 · Cited by 79
Cited by
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Self-citationArctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Self-citationFarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351279 · Cited by 469
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
Metadata
- Authors
- Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2004-03
- Volume
- 52
- Issue
- 3
- Pages
- 838-848
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W2099743383
- Cited by
- 662
- References
- 11
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.