The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Design of Implantable Microstrip Antenna for Communication With Medical Implants
Abstract
The objective of this paper is to design a microstrip patch antenna for communication with medical implants in the 402-405-MHz Medical Implant Communications Services band. Microstrip antenna design parameters are evaluated using the finite-difference time-domain method, and are compared to measured results. The effects of shape, length, size, location of feed point and ground point, substrate and superstrate materials, and their thicknesses are evaluated. An extensive study of the performance of the antennas to changes in these parameters was undertaken. The results of this paper provide guidance in the design of implantable microstrip antennas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Therapeutic applications of electromagnetic power
Guy, A. W., Lehmann, J. F., & Stonebridge, J. B. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9385 · Cited by 305
Furse, C. M., & Gandhi, O. P. (1998) · Bioelectromagnetics · Cited by 84
Self-citationRadiofrequency Catheter Ablation for Cardiac Tachyarrhythmias
Manolis, A. S., Wang, P. J., & Estes, N. A. M. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-121-6-199409150-00010 · Cited by 71
RF performance of a 418-MHz radio telemeter packaged for human vaginal placement
Scanlon, W. G., Evans, N. E., & McCreesh, Z. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568919 · Cited by 69
Lazzi, G., Pattnaik, S. S., Furse, C. M., et al. (1998) · IEEE Transactions on Antennas and Propagation · doi:10.1109/8.686784 · Cited by 34
Self-citationFDTD analysis of close-coupled 418 MHz radiating devices for human biotelemetry
Scanlon, W. G., Evans, N. E., & Burns, J. B. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/2/003 · Cited by 30
Cross-borehole delineation of a conductive ore deposit in a resistive host—experimental design
Johnson, D. E., Cherkaev, E., Furse, C. M., & Tripp, A. C. (2001) · Geophysics · doi:10.1190/1.1444972 · Cited by 14
Self-citation3D Modelling of the electromagnetic response of geophysical targets using the FDTD method1
Debroux, P. S. (1996) · Geophysical Prospecting · doi:10.1111/j.1365-2478.1996.tb00157.x · Cited by 12
Cited by
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Liu, C., Guo, Y.-X., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2307341 · Cited by 316
Huang, F.-J., Lee, C.-M., Chang, C.-L., Chen, L.-K., Yo, T.-C., & Luo, C.-H. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2152317 · Cited by 268
Chow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
Metadata
- Authors
- Soontornpipit, P., Furse, C. M., & Chung, Y. C.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2004-08
- Volume
- 52
- Issue
- 8
- Pages
- 1944-1951
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W2169832771
- Cited by
- 472
- References
- 8
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of Implantable Microstrip Antenna for Communication With Medical Implants. https://app.cochat.ai/papers/10.1109/tmtt.2004.831976
- The paper
- Soontornpipit, P., Furse, C. M., & Chung, Y. C. (2004). Design of Implantable Microstrip Antenna for Communication With Medical Implants. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2004.831976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.