The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz
Abstract
The dielectric parameters of the tissue simulating liquids to assess the exposure from mobile phones were determined in a previous study considering the tissue distribution of the exposed regions of the head using a planar layered model and the transmission-line method. Currently, the standards for the compliance testing of wireless devices are being extended to more general exposure situations. This paper uses the same methods considering different locations of the body and the respective variations of the tissue structures and dimensions. The analysis of tissue compositions shows a significant increase of 2.2-4.7 dB of the peak spatial specific absorption rate (SAR) in comparison to the values assessed with current standard liquids. This increase is due to standing-wave effects in tissues with low water content. For a certain distance between the antenna and the body (approximately /spl lambda//3 for a /spl lambda//2 dipole), these standing-wave effects dominate the coupling mechanism, leading to a higher average SAR in layered tissue. The observations were validated using finite-difference time-domain simulations of an anatomical high-resolution human model. Nevertheless, a sound conservative exposure assessment applying phantoms filled with homogeneous standardized liquids is possible if a distance and frequency-dependent scaling factor is applied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The skin layer with high water content is followed by a layer of SAT or layers of SAT and breast tissue, which have a comparatively low water content and only slightly attenuate the propagating waves (see Table II and [28]).”
BackgroundAbe, T., DeHoyos, D. V., Pollock, M. L., & Garzarella, L. (2000) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050027 · Cited by 523
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Self-citationRoy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Metadata
- Authors
- Christ, A., Klingenbock, A., Samaras, T., Goiceanu, C., & Kuster, N.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2006-05
- Volume
- 54
- Issue
- 5
- Pages
- 2188-2195
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W2163171438
- Cited by
- 207
- References
- 2
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz. https://app.cochat.ai/papers/10.1109/tmtt.2006.872789
- The paper
- Christ, A., Klingenbock, A., Samaras, T., Goiceanu, C., & Kuster, N. (2006). The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2006.872789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.