The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
EM algorithm system modeling by image-space techniques for PET reconstruction
Abstract
Methodology for PET system modeling using image-space techniques in the expectation maximization (EM) algorithm is presented. The approach, applicable to both list-mode data and projection data, is of particular significance to EM algorithm implementations which otherwise only use basic system models (such as those which calculate the system matrix elements on the fly). A basic version of the proposed technique can be implemented using image-space convolution, in order to include resolution effects into the system matrix, so that the EM algorithm gradually recovers the modeled resolution with each update. The improved system modeling (achieved by inclusion of two convolutions per iteration) results in both enhanced resolution and lower noise, and there is often no need for regularization-other than to limit the number of iterations. Tests have been performed with simulated list-mode data and also with measured projection data from a GE Advance PET scanner, for both [/sup 18/F]-FDG and [/sup 124/I]-NaI. The method demonstrates improved image quality in all cases when compared to the conventional FBP and EM methods presently used for clinical data (which do not include resolution modeling). The benefits of this approach for /sup 124/I (which has a low positron yield and a large positron range, usually resulting in noisier and poorer resolution images) are particularly noticeable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Physical Performance of the new hybrid PET/CT Discovery-690
Bettinardi, V., Presotto, L., Rapisarda, E., Picchio, M., Gianolli, L., & Gilardi, M. C. (2011) · Medical Physics · doi:10.1118/1.3635220 · Cited by 380
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142
PET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
Metadata
- Authors
- Reader, A. J., Julyan, P. J., Williams, H., Hastings, D. L., & Zweit, J.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2003-10
- Volume
- 50
- Issue
- 5
- Pages
- 1392-1397
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2151342077
- Cited by
- 191
- References
- 1
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EM algorithm system modeling by image-space techniques for PET reconstruction. https://app.cochat.ai/papers/10.1109/tns.2003.817327
- The paper
- Reader, A. J., Julyan, P. J., Williams, H., Hastings, D. L., & Zweit, J. (2003). EM algorithm system modeling by image-space techniques for PET reconstruction. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2003.817327
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.