An improved P300-based brain-computer interface
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a system for direct communication between brain and computer. The BCI developed in this work is based on a BCI described by Farwell and Donchin in 1988, which allows a subject to communicate one of 36 symbols presented on a 6 x 6 matrix. The system exploits the P300 component of event-related brain potentials (ERP) as a medium for communication. The processing methods distinguish this work from Donchin's work. In this work, independent component analysis (ICA) was used to separate the P300 source from the background noise. A matched filter was used together with averaging and threshold techniques for detecting the existence of P300s. The processing method was evaluated offline on data recorded from six healthy subjects. The method achieved a communication rate of 5.45 symbols/min with an accuracy of 92.1% compared to 4.8 symbols/min with an accuracy of 90% in Donchin's work. The online interface was tested with the same six subjects. The average communication rate achieved was 4.5 symbols/min with an accuracy of 79.5 % as apposed to the 4.8 symbols/min with an accuracy of 56 % in Donchin's work. The presented BCI achieves excellent performance compared to other existing BCIs, and allows a reasonable communication rate, while maintaining a low error rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 3×
“(For example, if the selected symbol was c, after 5 intensifications of the first row and 4 intensifications of the third column, the subject’s count should be 9). According to Farwell and Donchin [ 22 ], such a paradigm will elicit a P300 only when a target’s row (or column) intensification occurs.”
BackgroundMethodResultInfluentialBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Haykin, S. (1978) · Cited by 1,857
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
High-Order Contrasts for Independent Component Analysis
Cardoso, J.-F. (1999) · Neural Computation · doi:10.1162/089976699300016863 · Cited by 1,213
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Information Delivery and the Sensory Evoked Potential
Sutton, S., Tueting, P., Zubin, J., & John, E. R. (1967) · Science · doi:10.1126/science.155.3768.1436 · Cited by 696
Analysis and visualization of single‐trial event‐related potentials
Jung, T., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1050 · Cited by 655
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Current trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlogl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518
BCI Competition 2003—Data Set IIb: Support Vector Machines for the P300 Speller Paradigm
Kaper, M., Meinicke, P., Grossekathoefer, U., Lingner, T., & Ritter, H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826698 · Cited by 496
The thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493 · cited 2×
“require intensive training over several months [18]–[20], [25], the P300 BCI requires no training.”
BackgroundMethodBrain-computer interface research at the Wadsworth Center
Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847823 · Cited by 440
Makeig, S., Westerfield, M., Jung, T.-P., Covington, J., Townsend, J., Sejnowski, T. J., & Courchesne, E. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-07-02665.1999 · Cited by 385
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Graz-BCI: state of the art and clinical applications
Pfurtscheller, G., Neuper, C., Muller, G. R., Obermaier, B., Krausz, G., Schlogl, A., Scherer, R., Graimann, B., Keinrath, C., Skliris, D., et al. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814454 · Cited by 286
Brain–computer interface (BCI) operation: optimizing information transfer rates
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2003) · Biological Psychology · doi:10.1016/s0301-0511(03)00073-5 · Cited by 247
ERPs evoked by different matrix sizes: implications for a brain computer interface (BCI) system
Allison, B. Z., & Pineda, J. A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814448 · Cited by 225
EEG-based communication: a pattern recognition approach
Penny, W. D., Roberts, S. J., Curran, E. A., & Stokes, M. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847820 · Cited by 221
The Wadsworth Center brain-computer interface (BCI) research and development program
Wolpaw, J. R., McFarland, D. J., Vaughan, T. M., & Schalk, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814442 · Cited by 209
A direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Parallel man-machine training in development of EEG-based cursor control
Kostov, A., & Polak, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847816 · Cited by 174
A virtual reality testbed for brain-computer interface research
Bayliss, J. D., & Ballard, D. H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847811 · Cited by 161
Linear classification of low-resolution EEG patterns produced by imagined hand movements
Babiloni, F., Cincotti, F., Lazzarini, L., Millan, J., Mourino, J., Varsta, M., Heikkonen, J., Bianchi, L., & Marciani, M. G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847810 · Cited by 150
Toward a Direct Brain Interface Based on Human Subdural Recordings and Wavelet-Packet Analysis
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826671 · Cited by 120
Improving Transfer Rates in Brain Computer Interfacing: A Case Study
Meinicke, P., Kaper, M., Hoppe, F., Heumann, M., & Ritter, H. J. (2002) · PUB – Publications at Bielefeld University (Bielefeld University) · Cited by 109
Work toward real-time control of a cortical neural prothesis
Isaacs, R. E., Weber, D. J., & Schwartz, A. B. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847814 · Cited by 100
Modeling and estimation of single evoked brain potential components
Lange, D. H., Pratt, H., & Inbar, G. F. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623048 · Cited by 88
Self-citationThe use of EEG modifications due to motor imagery for brain-computer interfaces
Cincotti, F., Mattia, D., Babiloni, C., Carducci, F., Salinari, S., Bianchi, L., Marciani, M. G., & Babiloni, F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814455 · Cited by 64
Generalizing to new subjects in brain-computer interfacing
Kaper, M., & Ritter, H. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404214 · Cited by 38
A decision tree for brain-computer interface devices
Kennedy, P. R., & Adams, K. D. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814420 · Cited by 32
Probabilistic methods in BCI research
Sykacek, P., Roberts, S., Stokes, M., Curran, E., Gibbs, M., & Pickup, L. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814447 · Cited by 32
Toward a P300-based Computer Interface
Polikoff, J. B., & Bunnell, H. T. (2002) · Cited by 30
Research works printed but not linked: 3
- 10.1007/s004220100265 · doi:10.1007/s004220100265
- 10.1007/s004220100264 · doi:10.1007/s004220100264
- Bayliss, 2001, A flexible brain-computer interface, 56
Cited by
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Convolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Metadata
- Authors
- Serby, H., Yom-Tov, E., & Inbar, G. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-03
- Volume
- 13
- Issue
- 1
- Pages
- 89-98
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2120535393
- Cited by
- 403
- References
- 39
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.