An improved P300-based brain-computer interface
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a system for direct communication between brain and computer. The BCI developed in this work is based on a BCI described by Farwell and Donchin in 1988, which allows a subject to communicate one of 36 symbols presented on a 6 x 6 matrix. The system exploits the P300 component of event-related brain potentials (ERP) as a medium for communication. The processing methods distinguish this work from Donchin's work. In this work, independent component analysis (ICA) was used to separate the P300 source from the background noise. A matched filter was used together with averaging and threshold techniques for detecting the existence of P300s. The processing method was evaluated offline on data recorded from six healthy subjects. The method achieved a communication rate of 5.45 symbols/min with an accuracy of 92.1% compared to 4.8 symbols/min with an accuracy of 90% in Donchin's work. The online interface was tested with the same six subjects. The average communication rate achieved was 4.5 symbols/min with an accuracy of 79.5 % as apposed to the 4.8 symbols/min with an accuracy of 56 % in Donchin's work. The presented BCI achieves excellent performance compared to other existing BCIs, and allows a reasonable communication rate, while maintaining a low error rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 3×
“(For example, if the selected symbol was c, after 5 intensifications of the first row and 4 intensifications of the third column, the subject’s count should be 9). According to Farwell and Donchin [ 22 ], such a paradigm will elicit a P300 only when a target’s row (or column) intensification occurs.”
BackgroundMethodResultInfluentialBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Haykin, S. (1978) · Cited by 1,857
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
High-Order Contrasts for Independent Component Analysis
Cardoso, J.-F. (1999) · Neural Computation · doi:10.1162/089976699300016863 · Cited by 1,213
Research works printed but not linked: 3
- 10.1007/s004220100265 · doi:10.1007/s004220100265
- 10.1007/s004220100264 · doi:10.1007/s004220100264
- Bayliss, 2001, A flexible brain-computer interface, 56
Cited by
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Convolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749
A P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
“[15] achieved mean online accuracy of 79.”
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
“Others have used dynamic classifiers that stop when a classification criterion is met (e.g., Lenhardt et al., 2008; Serby et al., 2005); however, on average, the dynamic classifiers do not achieve online classification accuracy or practical bit rates as high as those reported here.”
BackgroundMethodInfluentialxDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537
BCI competition III: Dataset II—Ensemble of SVMs for BCI P300 speller
Rakotomamonjy, A., & Guigue, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915728 · Cited by 512
Sellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Estimating workload using EEG spectral power and ERPs in the n-back task
Brouwer, A.-M., Hogervorst, M. A., van Erp, J. B. F., Heffelaar, T., Zimmerman, P. H., & Oostenveld, R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/045008 · Cited by 407
“Besides classification accuracy, we calculated bitrate (as described in Serby et al (2005)) as a measure of performance that represents the amount of information being communicated, taking into account the number of possible options, the classification accuracy and the time required to communicate…”
MethodA Brain Controlled Wheelchair to Navigate in Familiar Environments
Rebsamen, B., Guan, C., Zhang, H., Wang, C., Teo, C., Ang, M. H., & Burdet, E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2049862 · Cited by 405
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Long, J., Li, Y., Wang, H., Yu, T., Pan, J., & Li, F. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2197221 · Cited by 293
Does the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
A tactile P300 brain-computer interface
Brouwer (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00019 · Cited by 278
A New Auditory Multi-Class Brain-Computer Interface Paradigm: Spatial Hearing as an Informative Cue
Schreuder, M., Blankertz, B., & Tangermann, M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009813 · Cited by 276
Motivation modulates the P300 amplitude during brain–computer interface use
Kleih, S. C., Nijboer, F., Halder, S., & Kübler, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.034 · Cited by 258
An Adaptive P300-Based Online Brain–Computer Interface
Lenhardt, A., Kaper, M., & Ritter, H. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.912816 · Cited by 190
“A similar approach was introduced by [ 7 ] which also adapts to the subjects online performance by limiting the number of subtrial presentations.”
BackgroundMethodResultInfluentialHow Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176
“Moreover, these results show accuracy levels similar to those of other studies that have used much more training data (Serby et al., 2005; Krusienski et al., 2006; Sellers et al., 2006, 2008; Nijboer et al., 2008).”
ResultToward a high-throughput auditory P300-based brain–computer interface
Klobassa, D. S., Vaughan, T. M., Brunner, P., Schwartz, N. E., Wolpaw, J. R., Neuper, C., & Sellers, E. W. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.04.019 · Cited by 165
“(Wolpaw et al., 2002; Serby et al., 2005) in which B is the number of bits per decision, N is the number of possible targets, and P is the accuracy probability.”
BackgroundMethodResultInfluentialA brain–computer interface using motion-onset visual evoked potential
Guo, F., Hong, B., Gao, X., & Gao, S. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/011 · Cited by 163
“Second, advanced signal processing techniques, such as independent component analysis (ICA) [40, 41] and support vector machine (SVM) [42, 43], can be adopted for mVEP extraction and target detection.”
MethodA High Performance Spelling System based on EEG-EOG Signals With Visual Feedback
Lee, M.-H., Williamson, J., Won, D.-O., Fazli, S., & Lee, S.-W. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2839116 · Cited by 163
“Therefore, predefining a fixed number of sequences as the threshold [29], [64], [65] will inevitably lead to suboptimal results.”
BackgroundAn adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 158
“…collected from the first few trials could allow adequately accurate communication) since presenting flashes after effective classification increases the time for each character selection and decreases the bit rate (Serby et al 2005, Allison and Pineda 2006, Lenhardt et al 2008, Townsend et al 2010).”
BackgroundMethodUnsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation
Lu, S., Guan, C., & Zhang, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2015197 · Cited by 122
“can then be identified by certain machine learning algorithms [7], [14]–[18].”
BackgroundHuman cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
PHOTHISONOTHAI, M., & NAKAGAWA, M. (2008) · IEICE Transactions on Information and Systems · doi:10.1093/ietisy/e91-d.1.44 · Cited by 33
Deshpande, G., Rangaprakash, D., Oeding, L., Cichocki, A., & Hu, X. P. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00246 · Cited by 29
Metadata
- Authors
- Serby, H., Yom-Tov, E., & Inbar, G. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-03
- Volume
- 13
- Issue
- 1
- Pages
- 89-98
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2120535393
- Cited by
- 403
- References
- 39
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.