CoChat

Sensorimotor rhythm-based brain-computer interface (BCI): feature selection by regression improves performance

McFarland, D.J., Wolpaw, J.R. · 2005 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 148

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

People can learn to control electroencephalogram (EEG) features consisting of sensorimotor rhythm amplitudes and can use this control to move a cursor in one or two dimensions to a target on a screen. In the standard one-dimensional application, the cursor moves horizontally from left to right at a fixed rate while vertical cursor movement is continuously controlled by sensorimotor rhythm amplitude. The right edge of the screen is divided among 2-6 targets, and the user's goal is to control vertical cursor movement so that the cursor hits the correct target when it reaches the right edge. Up to the present, vertical cursor movement has been a linear function of amplitude in a specific frequency band [i.e., 8-12 Hz (mu) or 18-26 Hz (beta)] over left and/or right sensorimotor cortex. The present study evaluated the effect of controlling cursor movement with a weighted combination of these amplitudes in which the weights were determined by an regression algorithm on the basis of the user's past performance. Analyses of data obtained from a representative set of trained users indicated that weighted combinations of sensorimotor rhythm amplitudes could support cursor control significantly superior to that provided by a single feature. Inclusion of an interaction term further improved performance. Subsequent online testing of the regression algorithm confirmed the improved performance predicted by the offline analyses. The results demonstrate the substantial value for brain-computer interface applications of simple multivariate linear algorithms. In contrast to many classification algorithms, such linear algorithms can easily incorporate multiple signal features, can readily adapt to changes in the user's control of these features, and can accommodate additional targets without major modifications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2005.848627

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 148

Metadata

Authors
McFarland, D. J., & Wolpaw, J. R.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2005-09
Volume
13
Issue
3
Pages
372-379
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2145482409
Cited by
148
References
4
FWCI
3.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensorimotor rhythm-based brain-computer interface (BCI): feature selection by regression improves performance. https://app.cochat.ai/papers/10.1109/tnsre.2005.848627
The paper
McFarland, D. J., & Wolpaw, J. R. (2005). Sensorimotor rhythm-based brain-computer interface (BCI): feature selection by regression improves performance. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2005.848627

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.