Sensorimotor rhythm-based brain-computer interface (BCI): feature selection by regression improves performance
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
People can learn to control electroencephalogram (EEG) features consisting of sensorimotor rhythm amplitudes and can use this control to move a cursor in one or two dimensions to a target on a screen. In the standard one-dimensional application, the cursor moves horizontally from left to right at a fixed rate while vertical cursor movement is continuously controlled by sensorimotor rhythm amplitude. The right edge of the screen is divided among 2-6 targets, and the user's goal is to control vertical cursor movement so that the cursor hits the correct target when it reaches the right edge. Up to the present, vertical cursor movement has been a linear function of amplitude in a specific frequency band [i.e., 8-12 Hz (mu) or 18-26 Hz (beta)] over left and/or right sensorimotor cortex. The present study evaluated the effect of controlling cursor movement with a weighted combination of these amplitudes in which the weights were determined by an regression algorithm on the basis of the user's past performance. Analyses of data obtained from a representative set of trained users indicated that weighted combinations of sensorimotor rhythm amplitudes could support cursor control significantly superior to that provided by a single feature. Inclusion of an interaction term further improved performance. Subsequent online testing of the regression algorithm confirmed the improved performance predicted by the offline analyses. The results demonstrate the substantial value for brain-computer interface applications of simple multivariate linear algorithms. In contrast to many classification algorithms, such linear algorithms can easily incorporate multiple signal features, can readily adapt to changes in the user's control of these features, and can accommodate additional targets without major modifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“We have proposed that the mutual adaptation of system and user is a necessary feature of successful BCI operation [7].”
BackgroundSelf-citationFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“In some systems, these features are potentials evoked by stereotyped stimuli [1], [2].”
BackgroundA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Self-citation
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Classification and regression approaches to BCI control of two-targets (adapted from [210]).”
BackgroundToward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Brain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Self-citationThe brain–computer interface cycle
Gerven, M. V., Farquhar, J., Schaefer, R., Vlek, R., Geuze, J., Nijholt, A., Ramsey, N., Haselager, P., Vuurpijl, L., Gielen, S., et al. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/041001 · Cited by 329
An EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
EEG-Based Strategies to Detect Motor Imagery for Control and Rehabilitation
Ang, K. K., & Guan, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2646763 · Cited by 289
Chai, R., Naik, G. R., Nguyen, T. N., Ling, S. H., Tran, Y., Craig, A., & Nguyen, H. T. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2532354 · Cited by 250
“This study explores the autoregressive (AR) model as it is an effective tool in EEG feature extraction algorithms, and will be used as a comparison to the PSD method [29]–[31].”
MethodBCI meeting 2005-workshop on BCI signal processing: feature extraction and translation
McFarland, D. J., Anderson, C. W., Muller, K.-R., Schlogl, A., & Krusienski, D. J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875637 · Cited by 204
“2) Space a) Laplacian filter [3], [9], [10], [16]–[18] b) Principal components analysis [8], [14] c) Independent components analysis [2], [16], [17] d) Common spatial patterns [7], [13], [19] e) Amplitudes [20] f) Ratios and differences”
MethodSelf-citationEmulation of computer mouse control with a noninvasive brain–computer interface
McFarland, D. J., Krusienski, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/001 · Cited by 202
Self-citationMotor Imagery Classification via Temporal Attention Cues of Graph Embedded EEG Signals
Zhang, D., Chen, K., Jian, D., & Yao, L. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2967128 · Cited by 199
“For example, [7] defined the mu band between 8–13 Hz, while [8] defined the mu band between”
BackgroundMcMullen, D. P., Hotson, G., Katyal, K. D., Wester, B. A., Fifer, M. S., McGee, T. G., Harris, A., Johannes, M. S., Vogelstein, R. J., Ravitz, A. D., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2294685 · Cited by 188
“Instead, the Burg algorithm was used to estimate the spectral power of the recorded iEEG signal with a sixteenth-order autoregressive model [42]; an estimate of the high gamma logpower was obtained for each window by computing the mean of the log-transformed spectral power in bins between 72.”
MethodMIN2Net: End-to-End Multi-Task Learning for Subject-Independent Motor Imagery EEG Classification
Autthasan, P., Chaisaen, R., Sudhawiyangkul, T., Rangpong, P., Kiatthaveephong, S., Dilokthanakul, N., Bhakdisongkhram, G., Phan, H., Guan, C., & Wilaiprasitporn, T. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3137184 · Cited by 187
Lotte, F. (2014) · Guide to Brain-Computer Music Interfacing · doi:10.1007/978-1-4471-6584-2_7 · Cited by 178
“To do so, one can use either regression algorithms (McFarland and Wolpaw, 2005) (Duda et al, 2001) or classification algorithms (Penny et al, 2000) (Lotte et al, 2007), the classification algorithms being by far the most used in the BCI community (Bashashati et al, 2007) (Lotte et al, 2007).”
MethodCritical issues in state-of-the-art brain–computer interface signal processing
Krusienski, D. J., Grosse-Wentrup, M., Galán, F., Coyle, D., Miller, K. J., Forney, E., & Anderson, C. W. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025002 · Cited by 168
Identification of task parameters from movement-related cortical potentials
Gu, Y., do Nascimento, O. F., Lucas, M.-F., & Farina, D. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0523-3 · Cited by 51
“For example, it may be possible to combine movements imagined from different limbs, as previously proposed [3, 22, 29, 31, 32, 38, 42], with movements imagined according to different parameters (RTDs or TTs); in this way, the number of control signals may double.”
Background
Metadata
- Authors
- McFarland, D. J., & Wolpaw, J. R.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-09
- Volume
- 13
- Issue
- 3
- Pages
- 372-379
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2145482409
- Cited by
- 148
- References
- 4
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.