Towards a robust BCI: error potentials and online learning
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Recent advances in the field of brain-computer interfaces (BCIs) have shown that BCIs have the potential to provide a powerful new channel of communication, completely independent of muscular and nervous systems. However, while there have been successful laboratory demonstrations, there are still issues that need to be addressed before BCIs can be used by nonexperts outside the laboratory. At IDIAP Research Institute, we have been investigating several areas that we believe will allow us to improve the robustness, flexibility, and reliability of BCIs. One area is recognition of cognitive error states, that is, identifying errors through the brain's reaction to mistakes. The production of these error potentials (ErrP) in reaction to an error made by the user is well established. We have extended this work by identifying a similar but distinct ErrP that is generated in response to an error made by the interface, (a misinterpretation of a command that the user has given). This ErrP can be satisfactorily identified in single trials and can be demonstrated to improve the theoretical performance of a BCI. A second area of research is online adaptation of the classifier. BCI signals change over time, both between sessions and within a single session, due to a number of factors. This means that a classifier trained on data from a previous session will probably not be optimal for a new session. In this paper, we present preliminary results from our investigations into supervised online learning that can be applied in the initial training phase. We also discuss the future direction of this research, including the combination of these two currently separate issues to create a potentially very powerful BCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holroyd, C. B., & Coles, M. G. H. (2002) · Psychological Review · doi:10.1037/0033-295x.109.4.679 · Cited by 4,027 · cited 2×
“Known as “feedback ErrP,” they occur when a user makes an error but is unaware of it until he or she is informed by feedback [8].”
BackgroundERP components on reaction errors and their functional significance: A tutorial
Falkenstein, M., Hoormann, J., Christ, S., & Hohnsbein, J. (2000) · Biological Psychology · doi:10.1016/s0301-0511(99)00031-9 · Cited by 1,442 · cited 1×
““Response ErrP” occur when the user makes an error and recognizes it immediately [6], [7].”
Background
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Galán, F., Nuttin, M., Lew, E., Ferrez, P. W., Vanacker, G., Philips, J., & Millán, J. D. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.001 · Cited by 660
Self-citationEnhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Iturrate, I., Antelis, J. M., Kubler, A., & Minguez, J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2020347 · Cited by 512
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Error-Related EEG Potentials Generated During Simulated Brain–Computer Interaction
Ferrez, P. W., & del R. Millan, J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908083 · Cited by 369
Self-citationAllison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350
EEG-Based Strategies to Detect Motor Imagery for Control and Rehabilitation
Ang, K. K., & Guan, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2646763 · Cited by 289
A survey of affective brain computer interfaces: principles, state-of-the-art, and challenges
Mühl, C., Allison, B., Nijholt, A., & Chanel, G. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.912881 · Cited by 282
Machine-learning-based coadaptive calibration for brain-computer interfaces
Vidaurre, C., Sannelli, C., Müller, K.-R., & Blankertz, B. (2011) · Neural Computation · doi:10.1162/neco_a_00089 · Cited by 207
Vidaurre, C., Schloogl, A., Cabeza, R., Scherer, R., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873542 · Cited by 195
Co-adaptive calibration to improve BCI efficiency
Vidaurre, C., Sannelli, C., Müller, K.-R., & Blankertz, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025009 · Cited by 169
Real-Time State Estimation in a Flight Simulator Using fNIRS
Gateau, T., Durantin, G., Lancelot, F., Scannella, S., & Dehais, F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0121279 · Cited by 167
“Research on “ passive ” BCIs provides interesting insight as they aim to infer the human operator ’ s cognitive state and then adapt the nature of the interactions to overcome cognitive bottlenecks [12, 13] such as WM limitations.”
BackgroundContext-aware adaptive spelling in motor imagery BCI
Perdikis, S., Leeb, R., & Millán, J. D. R. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036018 · Cited by 49
“Most early adaptive BCIs have implemented supervised approaches ( e.g., [ 9, 15, 25 ] ) .”
MethodSelf-citationSubject adaptation convolutional neural network for EEG-based motor imagery classification
Liu, S., Zhang, J., Wang, A., Wu, H., Zhao, Q., & Long, J. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac9c94 · Cited by 29
“First, different subjects have different neural responses to the same stimulus, and one subject can even have different neural responses to the same stimulus at different times and locations [19].”
Adaptive Methods in Machine Learning
Clerc, M., Daucé, E., & Mattout, J. (2016) · Brain–Computer Interfaces 1 · doi:10.1002/9781119144977.ch10 · Cited by 12
Metadata
- Authors
- Buttfield, A., Ferrez, P. W., & Millan, J. R.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-06
- Volume
- 14
- Issue
- 2
- Pages
- 164-168
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2131251829
- Cited by
- 181
- References
- 2
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.