A Haptic Knob for Rehabilitation of Hand Function
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper describes a novel two-degree-of-freedom robotic interface to train opening/closing of the hand and knob manipulation. The mechanical design, based on two parallelogram structures holding an exchangeable button, offers the possibility to adapt the interface to various hand sizes and finger orientations, as well as to right-handed or left-handed subjects. The interaction with the subject is measured by means of position encoders and four force sensors located close to the output measuring grasping and insertion forces. Various knobs can be mounted on the interface, including a cone mechanism to train a complete opening movement from a strongly contracted and closed hand to a large opened position. We describe the design based on measured biomechanics, the redundant safety mechanisms as well as the actuation and control architecture. Preliminary experiments show the performance of this interface and some of the possibilities it offers for the rehabilitation of hand function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840
The Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570 · cited 1×
“Pioneering work in robotic assisted rehabilitation of hand function was performed with the Rutgers Master II [9], a dedicated robotic glove with pneumatic actuators fixed to the palm to actuate each finger.”
MethodHesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489 · cited 2×
“[16], [17]. The BiManuTrack is a commercialized device that can train the latter two movements [ 18 ], [19].”
BackgroundRobotics, Motor Learning, and Neurologic Recovery
Reinkensmeyer, D. J., Emken, J. L., & Cramer, S. C. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140223 · Cited by 415
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374 · cited 2×
“Further, treatments may be designed to adapt to patient’s state [5], [6].”
BackgroundDevelopment of human precision grip I: Basic coordination of force
Forssberg, H., Eliasson, A. C., Kinoshita, H., Johansson, R. S., & Westling, G. (1991) · Experimental Brain Research · doi:10.1007/bf00229422 · Cited by 369 · cited 2×
“7 Nm or less, while pinching and manipulating small objects typically require forces smaller than 20 N (Table I) [21], [22].”
BackgroundHesse, S., Werner, C., Pohl, M., Rueckriem, S., Mehrholz, J., & Lingnau, M. L. (2005) · Stroke · doi:10.1161/01.str.0000177865.37334.ce · Cited by 331 · cited 1×
“[16], [17]. The BiManuTrack is a commercialized device that can train the latter two movements [18], [ 19 ].”
BackgroundRobot-assisted movement training for the stroke-impaired arm: Does it matter what the robot does?
Kahn, L. E., Lum, P. S., Rymer, W. Z., & Reinkensmeyer, D. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.03.0056 · Cited by 274 · cited 2×
“Further, treatments may be designed to adapt to patient’s state [5], [6].”
BackgroundEvidence-based physiotherapeutic concepts for improving arm and hand function in stroke patients
Woldag, H., & Hummelsheim, H. (2002) · Journal of Neurology · doi:10.1007/s004150200058 · Cited by 231 · cited 1×
“In particular, studies have shown that intense practice of repetitive movements can help improve the strength and functional use of the affected arm or hand [1]–[3].”
BackgroundKamper, D. G., & Rymer, W. Z. (2001) · Muscle & Nerve · doi:10.1002/mus.1054 · Cited by 219 · cited 1×
“, flexor muscles of the affected limb remain in a strongly contracted state preventing movements [20].”
BackgroundARMin - Design of a Novel Arm Rehabilitation Robot
Nef, T., & Riener, R. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501051 · Cited by 180 · cited 1×
“[ 16 ], [17]. The BiManuTrack is a commercialized device that can train the latter two movements [18], [19].”
BackgroundARMin - robot for rehabilitation of the upper extremities
Nef, T., Mihelj, M., Colombo, G., & Riener, R. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642181 · Cited by 179 · cited 1×
“[16], [ 17 ]. The BiManuTrack is a commercialized device that can train the latter two movements [18], [19].”
BackgroundA Virtual Reality—Based Exercise System for Hand Rehabilitation Post-Stroke
Adamovich, S. V., Merians, A. S., Boian, R., Lewis, J. A., Tremaine, M., Burdea, G. S., Recce, M., & Poizner, H. (2005) · Presence: Teleoperators and Virtual Environments · doi:10.1162/1054746053966996 · Cited by 172 · cited 1×
“Experiments with stroke patients showed an increase in range-of-motion (ROM) of fingers and force amplitude after training [10].”
BackgroundAdvances in the Understanding and Treatment of Stroke Impairment Using Robotic Devices
Hidler, J., Nichols, D., Pelliccio, M., & Brady, K. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/ryt5-62n4-ctvx-8jte · Cited by 171 · cited 1×
“Robot-assisted rehabilitation is a recent approach to stroke therapy which promises to redefine current clinical strategies [4].”
BackgroundIdentification of key pinch forces required to complete functional tasks
Smaby, N., Johanson, M. E., Baker, B., Kenney, D. E., Murray, W. M., & Hentz, V. R. (2004) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2004.02.0215 · Cited by 171 · cited 1×
“7 Nm or less, while pinching and manipulating small objects typically require forces smaller than 20 N (Table I) [21], [22].”
BackgroundA Robotic Device for Hand Motor Therapy after Stroke
Takahashi, C. D., Der-Yeghiaian, L., Le, V., & Cramer, S. C. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501041 · Cited by 164 · cited 1×
“A different kind of pneumatic device was presented in [14] to exercise wrist flexion/extension as well as grasping and releasing of real objects placed in the palm of the hand, using a structure that is fixed around the hand.”
A 2-DOF fMRI compatible haptic interface to investigate the neural control of arm movements
Gassert, R., Dovat, L., Lambercy, O., Ruffieux, Y., Chapuis, D., Ganesh, G., Burdet, E., & Bleuler, H. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642287 · Cited by 58
Self-citationControl System for Pneumatically Controlled Glove to Assist in Grasp Activities
Kline, T., Kamper, D. G., & Schmit, B. D. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501056 · Cited by 54 · cited 1×
“A pneumatic glove was also developed at Northwestern University [11], [12], which was used to train grasping and releasing of objects.”
MethodA Haptic Knob for Rehabilitation of Stroke Patients
Dovat, L., Lambercy, O., Ruffieux, Y., Chapuis, D., Gassert, R., Bleuler, H., Teo, C. L., & Burdet, E. (2006) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2006.281778 · Cited by 39
Self-citation
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Sensorimotor training in virtual reality: A review
Adamovich, S. V., Fluet, G. G., Tunik, E., & Merians, A. S. (2009) · NeuroRehabilitation · doi:10.3233/nre-2009-0497 · Cited by 507
Human-Like Adaptation of Force and Impedance in Stable and Unstable Interactions
Yang, C., Ganesh, G., Haddadin, S., Parusel, S., Albu-Schaeffer, A., & Burdet, E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2158251 · Cited by 397
Self-citation
Metadata
- Authors
- Lambercy, O., Dovat, L., Gassert, R., Burdet, E., Teo, C. L., & Milner, T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 356-366
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2105162422
- Cited by
- 196
- References
- 19
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.