A Haptic Knob for Rehabilitation of Hand Function
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper describes a novel two-degree-of-freedom robotic interface to train opening/closing of the hand and knob manipulation. The mechanical design, based on two parallelogram structures holding an exchangeable button, offers the possibility to adapt the interface to various hand sizes and finger orientations, as well as to right-handed or left-handed subjects. The interaction with the subject is measured by means of position encoders and four force sensors located close to the output measuring grasping and insertion forces. Various knobs can be mounted on the interface, including a cone mechanism to train a complete opening movement from a strongly contracted and closed hand to a large opened position. We describe the design based on measured biomechanics, the redundant safety mechanisms as well as the actuation and control architecture. Preliminary experiments show the performance of this interface and some of the possibilities it offers for the rehabilitation of hand function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840
The Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570 · cited 1×
“Pioneering work in robotic assisted rehabilitation of hand function was performed with the Rutgers Master II [9], a dedicated robotic glove with pneumatic actuators fixed to the palm to actuate each finger.”
MethodHesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489 · cited 2×
“[16], [17]. The BiManuTrack is a commercialized device that can train the latter two movements [ 18 ], [19].”
BackgroundRobotics, Motor Learning, and Neurologic Recovery
Reinkensmeyer, D. J., Emken, J. L., & Cramer, S. C. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140223 · Cited by 415
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374 · cited 2×
“Further, treatments may be designed to adapt to patient’s state [5], [6].”
BackgroundDevelopment of human precision grip I: Basic coordination of force
Forssberg, H., Eliasson, A. C., Kinoshita, H., Johansson, R. S., & Westling, G. (1991) · Experimental Brain Research · doi:10.1007/bf00229422 · Cited by 369 · cited 2×
“7 Nm or less, while pinching and manipulating small objects typically require forces smaller than 20 N (Table I) [21], [22].”
BackgroundHesse, S., Werner, C., Pohl, M., Rueckriem, S., Mehrholz, J., & Lingnau, M. L. (2005) · Stroke · doi:10.1161/01.str.0000177865.37334.ce · Cited by 331 · cited 1×
“[16], [17]. The BiManuTrack is a commercialized device that can train the latter two movements [18], [ 19 ].”
BackgroundRobot-assisted movement training for the stroke-impaired arm: Does it matter what the robot does?
Kahn, L. E., Lum, P. S., Rymer, W. Z., & Reinkensmeyer, D. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.03.0056 · Cited by 274 · cited 2×
“Further, treatments may be designed to adapt to patient’s state [5], [6].”
BackgroundEvidence-based physiotherapeutic concepts for improving arm and hand function in stroke patients
Woldag, H., & Hummelsheim, H. (2002) · Journal of Neurology · doi:10.1007/s004150200058 · Cited by 231 · cited 1×
“In particular, studies have shown that intense practice of repetitive movements can help improve the strength and functional use of the affected arm or hand [1]–[3].”
BackgroundKamper, D. G., & Rymer, W. Z. (2001) · Muscle & Nerve · doi:10.1002/mus.1054 · Cited by 219 · cited 1×
“, flexor muscles of the affected limb remain in a strongly contracted state preventing movements [20].”
Background
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Sensorimotor training in virtual reality: A review
Adamovich, S. V., Fluet, G. G., Tunik, E., & Merians, A. S. (2009) · NeuroRehabilitation · doi:10.3233/nre-2009-0497 · Cited by 507
Human-Like Adaptation of Force and Impedance in Stable and Unstable Interactions
Yang, C., Ganesh, G., Haddadin, S., Parusel, S., Albu-Schaeffer, A., & Burdet, E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2158251 · Cited by 397
Self-citationAng, K. K., Guan, C., Phua, K. S., Wang, C., Zhou, L., Tang, K. Y., Ephraim Joseph, G. J., Kuah, C. W. K., & Chua, K. S. G. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00030 · Cited by 361
EEG-Based Strategies to Detect Motor Imagery for Control and Rehabilitation
Ang, K. K., & Guan, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2646763 · Cited by 289
Robot-assisted rehabilitation of hand function
Balasubramanian, S., Klein, J., & Burdet, E. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32833e99a4 · Cited by 287
Self-citationDevelopment and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot
Schabowsky, C. N., Godfrey, S. B., Holley, R. J., & Lum, P. S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-36 · Cited by 280
Connelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047588 · Cited by 271
Chiri, A., Vitiello, N., Giovacchini, F., Roccella, S., Vecchi, F., & Carrozza, M. C. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2144614 · Cited by 254
Brokaw, E. B., Black, I., Holley, R. J., & Lum, P. S. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2157705 · Cited by 197
“Many of these actively actuated devices utilize internal grasp structures [3]–[5], but this diminishes the possibility of use with real world objects, and can limit range of motion (ROM).”
Babaiasl, M., Mahdioun, S. H., Jaryani, P., & Yazdani, M. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.1002539 · Cited by 182
“In the second class, the focus of training is on distal parts of the human arm such as hand [27], the wrist and the lower arm [28,29].”
BackgroundA robotic system to train activities of daily living in a virtual environment
Guidali, M., Duschau-Wicke, A., Broggi, S., Klamroth-Marganska, V., Nef, T., & Riener, R. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0809-0 · Cited by 181
“Nevertheless, initial clinical studies with devices like the MIT-Manus [16] for planar movements or the Haptic Knob [19] for distal functions have shown that patients can benefit from robotic therapy.”
BackgroundA structured overview of trends and technologies used in dynamic hand orthoses
Bos, R. A., Haarman, C. J. W., Stortelder, T., Nizamis, K., Herder, J. L., Stienen, A. H. A., & Plettenburg, D. H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0168-z · Cited by 162
“They are also the least similar to the type of therapy a physical therapist can provide, and their low use implies that these methods aYear ranges are determined by the year span between found literature sources and my differ from the actual time of development bActuator DOF = number of individually controlled actuato…”
BackgroundLambercy, O., Dovat, L., Yun, H., Wee, S. K., Kuah, C. W., Chua, K. S., Gassert, R., Milner, T. E., Teo, C. L., & Burdet, E. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-63 · Cited by 144
“While these values are far from the maximum force/torque a healthy subject can generate (about 450N in grasping and 20Nm in pronation/supination), they are sufficient to provide challenging exercises for stroke patients and simulate typical ADL manipulation tasks [15].”
BackgroundSelf-citationThe Task-Dependent Efficacy of Shared-Control Haptic Guidance Paradigms
Powell, D., & O'Malley, M. K. (2012) · IEEE Transactions on Haptics · doi:10.1109/toh.2012.40 · Cited by 94
“[37] designed a haptic knob offering varying levels of resistive force in order to help stroke patients regain grasp strength and coordination.”
Background
Metadata
- Authors
- Lambercy, O., Dovat, L., Gassert, R., Burdet, E., Teo, C. L., & Milner, T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 356-366
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2105162422
- Cited by
- 196
- References
- 19
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.