Real-Time Classification of Forearm Electromyographic Signals Corresponding to User-Selected Intentional Movements for Multifunction Prosthesis Control
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Pattern recognition-based multifunction prosthesis control strategies have largely been demonstrated with subsets of typical able-bodied hand movements. These movements are often unnatural to the amputee, necessitating significant user training and do not maximally exploit the potential of residual muscle activity. This paper presents a real-time electromyography (EMG) classifier of user-selected intentional movements rather than an imposed subset of standard movements. EMG signals were recorded from the forearm extensor and flexor muscles of seven able-bodied participants and one congenital amputee. Participants freely selected and labeled their own muscle contractions through a unique training protocol. Signals were parameterized by the natural logarithm of root mean square values, calculated within 0.2 s sliding and non overlapping windows. The feature space was segmented using fuzzy C-means clustering. With only 2 min of training data from each user, the classifier discriminated four different movements with an average accuracy of 92.7% +/- 3.2%. This accuracy could be further increased with additional training data and improved user proficiency that comes with practice. The proposed method may facilitate the development of dynamic upper extremity prosthesis control strategies using arbitrary, user-preferred muscle contractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 7×
“With time domain features [4], [6], [11], [12], [19], thresholds have been required in the calculation of zero-crossings and amplitude inflexion points [ 4 ].”
BackgroundMethodResultInfluentialA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 8×
“Generally for prosthesis control, participants must adhere to a subset of typical contractions associated with normative hand movements of the able-bodied limb (e.g., wrist flexion/extension, finger flexion/extension, pronation/supination) [3], [5], [ 6 ], [11], [12], [17]‐[19], [22], [25].”
BackgroundMethodResultInfluentialA heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Cited by
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
“To estimate the real-time classification error, during the evaluation phases, the participant was given five seconds from the time of the cue to generate the corresponding movement (as in [20]).”
BackgroundMethodEMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton
Yin, Y. H., Fan, Y. J., & Xu, L. D. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2178034 · Cited by 197
Metadata
- Authors
- Momen, K., Krishnan, S., & Chau, T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-12
- Volume
- 15
- Issue
- 4
- Pages
- 535-542
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2146409459
- Cited by
- 152
- References
- 4
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Classification of Forearm Electromyographic Signals Corresponding to User-Selected Intentional Movements for Multifunction Prosthesis Control. https://app.cochat.ai/papers/10.1109/tnsre.2007.908376
- The paper
- Momen, K., Krishnan, S., & Chau, T. (2007). Real-Time Classification of Forearm Electromyographic Signals Corresponding to User-Selected Intentional Movements for Multifunction Prosthesis Control. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2007.908376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.