P300-Based BCI Mouse With Genetically-Optimized Analogue Control
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In this paper we propose a brain-computer interface (BCI) mouse based on P300 waves in electroencephalogram (EEG) signals. The system is analogue in that at no point a binary decision is made as to whether or not a P300 was actually produced in response to the stimuli. Instead, the 2-D motion of the pointer on the screen, using a novel BCI paradigm, is controlled by directly combining the amplitudes of the output produced by a filter in the presence of different stimuli. This filter and the features to be combined within it are optimised by an evolutionary algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Is the P300 component a manifestation of context updating?
Donchin, E., & Coles, M. G. H. (1988) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00058027 · Cited by 3,585 · cited 1×
“ERPs include an exogenous response, due to the primary processing of the stimulus, as well as an endogenous response, which is a reflection of higher cognitive processing induced by the stimulus [22].”
BackgroundFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“The signals used in BCI studies to date include P300 waves [1] and other event related potentials (ERPs), or rhythms [2], evoked potentials (EPs) [6], [16]–[20], event-related desynchronization/synchronization (ERD/ERS) [3], activation patterns induced by mental task strategies [21], slow cortical potentials [ 4 ] rec…”
MethodControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Patients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Curran, E. (2003) · Brain and Cognition · doi:10.1016/s0278-2626(03)00036-8 · Cited by 417
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
The Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
“While the mainstream of research addressed improvements of paradigms (Hill et al., 2005; Citi et al., 2008; McFarland et al., 2008; Hwang et al., 2009; Williamson et al., 2009; Höhne et al., 2010; Schaefer et al., 2010; Schreuder et al., 2010; Treder and Blankertz, 2010) and data analysis…”
BackgroundP300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Does the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
Metadata
- Authors
- Citi, L., Poli, R., Cinel, C., & Sepulveda, F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-02
- Volume
- 16
- Issue
- 1
- Pages
- 51-61
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2162542193
- Cited by
- 145
- References
- 8
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: P300-Based BCI Mouse With Genetically-Optimized Analogue Control. https://app.cochat.ai/papers/10.1109/tnsre.2007.913184
- The paper
- Citi, L., Poli, R., Cinel, C., & Sepulveda, F. (2008). P300-Based BCI Mouse With Genetically-Optimized Analogue Control. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2007.913184
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.