Unsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Conventional brain computer interfaces rely on a guided calibration procedure to address the problem of considerable variations in electroencephalography (EEG) across human subjects. This calibration, however, implies inconvenience to the end users. In this paper, we propose an online-adaptive-learning method to address this problem for P300-based brain computer interfaces. By automatically capturing subject-specific EEG characteristics during online operation, this method allows a new user to start operating a P300-based brain-computer interface without guided (supervised) calibration. The basic principle is to first learn a generic model termed subject-independent model offline from EEG of a pool of subjects to capture common P300 characteristics. For a new user, a new model termed subject-specific model is then adapted online based on EEG recorded from the new subject and the corresponding labels predicted by either the subject-independent model or the adapted subject-specific model, depending on a confidence score. To verify the proposed method, a study involving 10 healthy subjects is carried out and positive results are obtained. For instance, after 2-4 min online adaptation (spelling of 10-20 characters), the accuracy of the adapted model converges to that of a fully trained supervised subject-specific model.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Pattern Recognition and Neural Networks
Ripley, B. D. (1996) · Cambridge University Press eBooks · doi:10.1017/cbo9780511812651 · Cited by 6,459
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Farwell and Donchin [13] first demonstrate the use of P300 for BCIs in a so-called oddball paradigm.”
BackgroundPattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“T HE emerging technology of brain–computer interfaces (BCIs) has attracted increasing interests from multidisciplinary domains [1]–[4].”
BackgroundAugmenting mental chronometry: The P300 as a measure of stimulus evaluation time
Kutas, M., McCarthy, G., & Donchin, E. (1977) · Science · doi:10.1126/science.887923 · Cited by 1,714 · cited 2×
“Though many studies [19]–[21] have shown that P300 varies across subjects, different subjects usually share common wave-”
BackgroundThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762 · cited 1×
“As evaluated in [27], support vector machine (SVM) and Fisher’s linear discriminant (FLD) outperforms others in most cases.”
MethodToward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 1×
“The SynAmpls2 has 64 monopolar channels and we just use eight channels that are proposed in [30].”
MethodGenerators of the late cognitive potentials in auditory and visual oddball tasks
Halgren, E., Marinkovic, K., & Chauvel, P. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00119-3 · Cited by 640 · cited 1×
“P300 is an endogenous event-related potential (ERP) which presents as a positive deflection at a latency of around 300 ms after the onset of external stimuli [11], [12].”
BackgroundBCI Competition 2003—Data Set IIb: Support Vector Machines for the P300 Speller Paradigm
Kaper, M., Meinicke, P., Grossekathoefer, U., Lingner, T., & Ritter, H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826698 · Cited by 496 · cited 1×
“can then be identified by certain machine learning algorithms [7], [14]–[18].”
BackgroundMultichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449 · cited 2×
“The mu–beta training in [5] requires each subject to participate in three training sessions per week where each training session takes around 30 min and the whole training process lasts up to 6–8 weeks.”
BackgroundCurran, E. (2003) · Brain and Cognition · doi:10.1016/s0278-2626(03)00036-8 · Cited by 417
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403 · cited 1×
“can then be identified by certain machine learning algorithms [7], [14]–[18].”
BackgroundGuest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Robust classification of EEG signal for brain-computer interface
Thulasidas, M., Guan, C., & Wu, J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.862695 · Cited by 261 · cited 1×
“P300-based word speller reported in our earlier work [16].”
ResultSelf-citationXu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258 · cited 2×
“Currently, user calibration is still an important part of electroencephalography (EEG)-based BCIs because of considerable variations across subjects [5]–[7].”
BackgroundLi, Y., Guan, C., Li, H., & Chin, Z. (2008) · Pattern Recognition Letters · doi:10.1016/j.patrec.2008.01.030 · Cited by 228 · cited 1×
“[8], [9] propose to reduce the training data through self-training that first learns a weak classifier from a small amount of labeled data and then improves the weak classifier based on unlabeled data and corresponding labels predicted by the weak classifier itself.”
BackgroundSelf-citationBlankertz, B., Dornhege, G., Schafer, C., Krepki, R., Kohlmorgen, J., Muller, K.-R., Kunzmann, V., Losch, F., & Curio, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814456 · Cited by 226 · cited 1×
“[6] propose to reduce the training data for motor imagery through the regularization of the covariance matrix that needs to be evaluated for Fisher’s linear discriminant.”
BackgroundA direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
On the relationship between EEG and P300: individual differences, aging, and ultradian rhythms
Polich, J. (1997) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00772-1 · Cited by 186 · cited 2×
“The proposed technique is based on three observations [20], [22], [23] including: 1) P300 of the same subject is pretty consistent within a short period (say, 5–10 h), though it may vary after a long period of time such as aging; 2) P300 of different subjects shares common waveform characteristic as defined, namely, a…”
BackgroundMethodAsynchronous P300-Based Brain--Computer Interfaces: A Computational Approach With Statistical Models
Zhang, H., Guan, C., & Wang, C. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919128 · Cited by 175
Self-citationP3 latency and symbol digit performance correlations in aging
Emmerson, R. Y., Dustman, R. E., Shearer, D. E., & Turner, C. W. (1989) · Experimental Aging Research · doi:10.1080/03610738908259769 · Cited by 113 · cited 1×
“The proposed technique is based on three observations [20], [22], [23] including: 1) P300 of the same subject is pretty consistent within a short period (say, 5–10 h), though it may vary after a long period of time such as aging; 2) P300 of different subjects shares common waveform characteristic as defined, namely, a…”
MethodNoldy, N. E., Stelmack, R. M., & Campbell, K. B. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02337.x · Cited by 110 · cited 2×
“Though many studies [19]–[21] have shown that P300 varies across subjects, different subjects usually share common wave-”
BackgroundLi, Y., & Guan, C. (2007) · Machine Learning · doi:10.1007/s10994-007-5039-1 · Cited by 70 · cited 2×
“As described in Algorithm I, the proposed technique derives an ASSCM through an online adaptation process, which is actually very similar to the semi-supervised learning that is often used while only a small amount of labeled training data is available [8].”
BackgroundMethodSelf-citationEEG ocular artifact removal through ARMAX model system identification using extended least squares
Haas, S. M., Frei, M. G., Osorio, I., Pasik-Duncan, B., & Radel, J. D. (2003) · Communications in Information and Systems · doi:10.4310/cis.2003.v3.n1.a2 · Cited by 50 · cited 1×
“Ocular artifacts are then removed by treating each epoched EEG as a linear superposition of the electrooculograph (EOG) and the real EEG as follows [25], [26]:”
MethodBrain interface research for asynchronous control applications
Borisoff, J. F., Mason, S. G., & Birch, G. E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875526 · Cited by 46 · cited 1×
“P300 is an endogenous event-related potential (ERP) which presents as a positive deflection at a latency of around 300 ms after the onset of external stimuli [11], [12].”
BackgroundEffect of ocular artifact removal in brain computer interface accuracy
Thulasidas, M., Guan, C., Ranganatha, S., Wu, J., Zhu, X., & Xu, W. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404220 · Cited by 12 · cited 1×
“Ocular artifacts are then removed by treating each epoched EEG as a linear superposition of the electrooculograph (EOG) and the real EEG as follows [25], [26]:”
MethodSelf-citationRobust classification of event-related potential for brain-computer interface
Thulasidas, M. (2004) · Singapore Management University Institutional Knowledge (InK) (Singapore Management University) · Cited by 10
Learning adaptive subject-independent P300 models for EEG-based brain-computer interfaces
Lu, S., Guan, C., & Zhang, H. (2008) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2008.4634141 · Cited by 4 · cited 1×
“It extends and consolidates our earlier work [10] on preliminary research of adaptive P300-based BCIs.”
BackgroundSelf-citation
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Some unsupervised methods rely on techniques for co-adaptive learning of user and machine [218,219] or covariate shift adaptation [220].”
MethodCombining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
“has also been applied to P300 data [107] and to motor imagery data [17, 180, 195].”
MethodA review on transfer learning in EEG signal analysis
Wan, Z., Yang, R., Huang, M., Zeng, N., & Liu, X. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.09.017 · Cited by 468
The Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
“…attempts have been made to overcome the calibration by means of specifically developed machine learning techniques, e.g., Kaper and Ritter (2004), Lu et al. (2009) for P300 and Allison et al. (2008), Cecotti (2010) for SSVEP as well as Krauledat et al. (2008) for SMR-based BCIs where feedback…”
Method
Metadata
- Authors
- Lu, S., Guan, C., & Zhang, H.
- Affiliations
- Institute for Infocomm Research (SG)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-04
- Volume
- 17
- Issue
- 2
- Pages
- 135-145
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2141333870
- Cited by
- 122
- References
- 32
- Citations by year
- 2025: 1 · 2023: 3 · 2022: 1 · 2021: 6 · 2020: 16 · 2019: 6 · 2018: 8 · 2017: 5 · 2016: 10 · 2015: 13 · 2014: 14 · 2013: 14 · 2012: 6
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- brain-computer interface, P300, unsupervised calibration, online adaptation, subject-specific modeling, EEG
- MeSH terms
- Algorithms, Brain, Calibration, Data Collection, Electroencephalography, Humans, Online Systems, Reference Values, User-Computer Interface, Reproducibility of Results, Models, Statistical, Event-Related Potentials, P300
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.