Wireless Neural Recording With Single Low-Power Integrated Circuit
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We present benchtop and in vivo experimental results from an integrated circuit designed for wireless implantable neural recording applications. The chip, which was fabricated in a commercially available 0.6- mum 2P3M BiCMOS process, contains 100 amplifiers, a 10-bit analog-to-digital converter (ADC), 100 threshold-based spike detectors, and a 902-928 MHz frequency-shift-keying (FSK) transmitter. Neural signals from a selected amplifier are sampled by the ADC at 15.7 kSps and telemetered over the FSK wireless data link. Power, clock, and command signals are sent to the chip wirelessly over a 2.765-MHz inductive (coil-to-coil) link. The chip is capable of operating with only two off-chip components: a power/command receiving coil and a 100-nF capacitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“, [1]), the need for completely wireless neural recording systems becomes more important.”
BackgroundA low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Self-citationA Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
Self-citationThe Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330 · cited 1×
“The design strategies used to minimize amplifier power dissipation and reduce data rate have previously been described in [10].”
MethodSelf-citationDesigning Efficient Inductive Power Links for Implantable Devices
Harrison, R. R. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378508 · Cited by 244 · cited 1×
“Techniques described in [ 16 ] were used to optimize the power link.”
MethodSelf-citationWireless multichannel biopotential recording using an integrated FM telemetry circuit
Mohseni, P., Najafi, K., Eliades, S. J., & Wang, X. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.853625 · Cited by 219 · cited 1×
“Advances in circuit integration have led to the development of biopotential recording systems with wireless data telemetry (see [2] and references therein).”
BackgroundThermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain
Kim, S., Tathireddy, P., Normann, R. A., & Solzbacher, F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908429 · Cited by 214 · cited 1×
“The goal of this project is to create a small (less than 1 cm), implantable neural recording system with low power dissipation (approximately 10 mW) so that surrounding tissues are not damaged by chronic heating [5].”
BackgroundSelf-citationHermesC: Low-Power Wireless Neural Recording System for Freely Moving Primates
Chestek, C. A., Gilja, V., Nuyujukian, P., Kier, R. J., Solzbacher, F., Ryu, S. I., Harrison, R. R., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023293 · Cited by 130
Self-citationSwitchable polymer-based thin film coils as a power module for wireless neural interfaces
Kim, S., Zoschke, K., Klein, M., Black, D., Buschick, K., Toepper, M., Tathireddy, P., Harrison, R. R., Oppermann, H. H., & Solzbacher, F. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.10.048 · Cited by 31 · cited 1×
“A 5-mm gold coil can be attached to the back of the chip and used for receiving power and command signals [9].”
MethodSelf-citationHermesC: RF wireless low-power neural recording system for freely behaving primates
Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Shenoy, K. V., Kier, R. J., Solzbacher, F., & Harrison, R. R. (2008) · 2008 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2008.4541777 · Cited by 25 · cited 2×
“A companion paper [6] presents data obtained from freely behaving rhesus macaques using this integrated circuit.”
BackgroundSelf-citationWireless neural signal acquisition with single low-power integrated circuit
Harrison, R. R., Kier, R. J., Greger, B. E., Solzbacher, F., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4541776 · Cited by 15 · cited 1×
“Portions of this work have been previously presented in conference form [7], [8].”
Self-citationPower minimization of a 433-MHz LC VCO for an implantable neural recording system
Kier, R. J., & Harrison, R. R. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1693312 · Cited by 12 · cited 1×
“The minimum power dissipation of oscillators required to sustain oscillation is a function of inductor losses [15].”
BackgroundSelf-citationPackaging concepts for neuroprosthetic implants
Topper, M. J., Klein, M., Wilke, M., Oppermann, H. H., Kim, S., Tathireddy, P., Solzbacher, F., & Reichl, H. (2007) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · Cited by 4
Self-citationYin, M., & Ghovanloo, M. (2007) · doi:10.1109/newcas.2007.4487954 · Cited by 4 · cited 1×
“capacitance in a DCO is directly controlled by an 8-bit digital control word (see also [11]–[14]).”
Method
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
“These implantable devices, which use the HF band, overcome the limited operational range associated with previously reported systems (Hannan et al., 2014; Harrison et al., 2009).”
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(52, 53) Other developments that are being pursued include the addition of optical waveguides for optogentic research.”
BackgroundChestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Self-citation
Metadata
- Authors
- Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S., Greger, B., Solzbacher, F., & Shenoy, K. V.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-08
- Volume
- 17
- Issue
- 4
- Pages
- 322-329
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2160997918
- Cited by
- 209
- References
- 14
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.