Examination of Force Discrimination in Human Upper Limb Amputees With Reinnervated Limb Sensation Following Peripheral Nerve Transfer
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Artificial limbs allow amputees to manipulate objects, but the loss of a limb severs the sensory link between a subject and objects they touch. A novel surgical technique we term targeted reinnervation (TR) allows severed cutaneous nerves to reinnervate skin on a different portion of the body. This technique provides a physiologically appropriate portal to the sensory pathways of the missing limb through the reinnervated skin. This study quantified the ability of three amputee subjects who had undergone TR surgery on the chest (two subjects) and upper arm (one subject) to discriminate changes in graded force on their reinnervated skin over a range of 1-4 N using a stochastic staircase approach. These values were compared to those from sites on their intact contralateral skin and index fingers, and from the chests and index fingers of a control population (n = 10) . Weber's ratio (WR) was used to examine the subjects' abilities to discriminate between a baseline force and subsequent forces of different magnitudes. WRs of 0.22, 0.25, and 0.12 were measured on the reinnervated skin of the three TR subjects, whereas WRs of 0.25, 0.23, and 0.12 were measured on their contralateral skin. TR subjects did not have substantially different WRs on their reinnervated versus their contralateral normal side and did not appear to exhibit a trend towards impaired sensation. No significant difference was found between the WR of the chest and index finger of the control subjects, which ranged between 0.09 and 0.21. WR of reinnervated skin for TR subjects were within the 95% confidence interval of the control group. These data suggest that subjects with targeted reinnervation have unimpaired ability to discriminate gradations in force.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105 · cited 1×
“37 identified as a statistical outlier using Grubbs’ test [21] that was not included in analyses, and a mean value of .”
Jones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citationClosed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“graded pressure may play an important role in such feedback systems [10], [11], perception of tangential force discrimina-”
Schultz, A. E., Marasco, P. D., & Kuiken, T. A. (2009) · Brain Research · doi:10.1016/j.brainres.2008.11.039 · Cited by 58 · cited 1×
“This location also previously showed normal physiologic response to vibratory input [20].”
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
“the harder the target skin is pushed the stronger the projected sensation (Sensinger et al., 2009).”
BackgroundSelf-citationSchultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
“Patients can feel light touch, graded pressure, vibration, sharp/dull stimuli, and hot/cold stimuli, with all these sensations perceived on their missing hand or arm [29-31].”
BackgroundSelf-citationInterfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“Using TR, sensation in the hand as evoked by a reinnervated chest skin along with other senses like touch, temperature, pain, and a limited graded force discrimination have been demonstrated ( Kuiken et al., 2007b; Marasco et al., 2009, 2011; Schultz et al., 2009; Sensinger et al., 2009).”
Metadata
- Authors
- Sensinger, J. W., Schultz, A. E., & Kuiken, T. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-10
- Volume
- 17
- Issue
- 5
- Pages
- 438-444
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2144183315
- Cited by
- 39
- References
- 7
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Examination of Force Discrimination in Human Upper Limb Amputees With Reinnervated Limb Sensation Following Peripheral Nerve Transfer. https://app.cochat.ai/papers/10.1109/tnsre.2009.2032640
- The paper
- Sensinger, J. W., Schultz, A. E., & Kuiken, T. A. (2009). Examination of Force Discrimination in Human Upper Limb Amputees With Reinnervated Limb Sensation Following Peripheral Nerve Transfer. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2009.2032640
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.