Design and Implementation of a P300-Based Brain-Computer Interface for Controlling an Internet Browser
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
An electroencephalographic (EEG) brain-computer interface (BCI) internet browser was designed and evaluated with 10 healthy volunteers and three individuals with advanced amyotrophic lateral sclerosis (ALS), all of whom were given tasks to execute on the internet using the browser. Participants with ALS achieved an average accuracy of 73% and a subsequent information transfer rate (ITR) of 8.6 bits/min and healthy participants with no prior BCI experience over 90% accuracy and an ITR of 14.4 bits/min. We define additional criteria for unrestricted internet access for evaluation of the presented and future internet browsers, and we provide a review of the existing browsers in the literature. The P300-based browser provides unrestricted access and enables free web surfing for individuals with paralysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“The P300 Speller paradigm, pioneered by Farwell and Donchin in 1988, utilizes this response by displaying characters in a matrix and briefly highlighting every row and column in the matrix [ 29 ].”
MethodBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024 · cited 1×
“The duration of character selection by the BCI2000 module [ 30 ] is derived from the number of required iterative, highlighting sequences of stimuli as well as stimulus duration and inter-stimulus interval.”
MethodCognitive and biological determinants of P300: an integrative review
Polich, J., & Kok, A. (1995) · Biological Psychology · doi:10.1016/0301-0511(95)05130-9 · Cited by 1,613 · cited 1×
“The P300 ERP is elicited approximately 300 ms after presentation of rarely-occurring or “oddball” stimuli in a sequence of standard stimuli [27], [ 28 ].”
BackgroundThe Diagnosis of Stupor and Coma.
(1967) · Annals of Internal Medicine · doi:10.7326/0003-4819-66-1-244 · Cited by 1,152
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Pritchard, W. S. (1981) · PubMed · Cited by 852
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Pritchard, W. S. (1981) · Psychological Bulletin · doi:10.1037/0033-2909.89.3.506 · Cited by 768 · cited 1×
“The P300 ERP is elicited approximately 300 ms after presentation of rarely-occurring or “oddball” stimuli in a sequence of standard stimuli [ 27 ], [28].”
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762 · cited 1×
“Although this quantity was variable for each individual, a lower limit of five sequences was set to maintain consistency in the individual result [10], [ 38 ].”
Background
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“[128] built an Internet browser with P300 control where the options are all presented as icons in an 8x8 matrix.”
BackgroundMethodBrain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
Lazarou, I., Nikolopoulos, S., Petrantonakis, P. C., Kompatsiaris, I., & Tsolaki, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00014 · Cited by 335
Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
Development of an SSVEP-based BCI spelling system adopting a QWERTY-style LED keyboard
Hwang, H.-J., Lim, J.-H., Jung, Y.-J., Choi, H., Lee, S. W., & Im, C.-H. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.011 · Cited by 251
“…have been developed in order to improve people’s quality of lives, e.g., mental typing of a keyboard (Sellers et al., 2010), controlling of a mouse cursor (Fabiani et al., 2004), navigating of a web browser (Mugler et al., 2010), operating of a wheelchair (Rebsamen et al., 2010), and so on.”
Hramov, A. E., Maksimenko, V. A., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 213
Münßinger, J. I., Halder, S., Kleih, S. C., Furdea, A., Raco, V., Hösle, A., & Kübler, A. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00182 · Cited by 175
“One such BCI application, the P300-based “neural signal surfing interface (NESSI)”, enables paralyzed patients to use the internet with accuracies of about 72% (Bensch et al., 2007; Mugler et al., 2008, 2010).”
BackgroundSelf-citationBrain–computer interfaces: the innovative key to unlocking neurological conditions
Zhang, H., Jiao, L., Yang, S., Li, H., Jiang, X., Feng, J., Zou, S., Xu, Q., Gu, J., Wang, X., et al. (2024) · International Journal of Surgery · doi:10.1097/js9.0000000000002022 · Cited by 169
“The P300 paradigm, based on attention to visual stimuli, generates responses to infrequent events and is employed in emergency communication systems [73 – 75] .”
MethodMoghimi, S., Kushki, A., Marie Guerguerian, A., & Chau, T. (2013) · Assistive Technology · doi:10.1080/10400435.2012.723298 · Cited by 166
Decoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
“…BCI systems using EEG depend on motor imagery (Onose et al., 2012; Kevric and Subasi, 2017), event-related potential (ERP) (Sellers et al., 2006; Mugler et al., 2010; Xu et al., 2018b; Fouad et al., 2020) or steady state visually evoked potentials (SSVEP) (Müller-Putz et al., 2005; Han et al.,…”
MethodHolz, E. M., Höhne, J., Staiger-Sälzer, P., Tangermann, M., & Kübler, A. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.08.001 · Cited by 111
“CIs have been developed for communication [2–4], entertainment 5–7], e-inclusion [2,8] and environmental control, e.”
BackgroundSelf-citationAghili, S. N., & Erfanian, A. (2023) · IEEE Access · doi:10.1109/access.2023.3313260 · Cited by 12
“vehicle [17], [18], [19], [20], smart home environment [1], [18], web browser [8], [21], [22], and playing game [13], [23].”
Background
Metadata
- Authors
- Mugler, E. M., Ruf, C. A., Halder, S., Bensch, M., & Kubler, A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-12
- Volume
- 18
- Issue
- 6
- Pages
- 599-609
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2118040411
- Cited by
- 181
- References
- 44
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.