Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia

Ortner, Rupert, Allison, Brendan Z., Korisek, Gerd, Gaggl, Herbert, Pfurtscheller, Gert·2011·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Brain-computer interface (BCI) systems allow people to send messages or commands without moving, and hence can provide an alternative communication and control channel for people with limited motor function. In this study, we demonstrate a BCI system for orthosis control. Our BCI was asynchronous, meaning that subjects could move the orthosis whenever they wanted, instead of pacing themselves to external cues. Seven subjects each performed two tasks with a BCI that relied on steady state visual evoked potentials (SSVEPs). Although none of the subjects had any training, six subjects showed good control with a positive predictive value (PPV) higher than 60%. The overall PPV for all subjects reached 78% ±10%. However, the false positive rate was high, and some subjects dislike the flickering lights required in SSVEP BCIs. In follow-up work, we hope to reduce both the false positive rate and the annoyance produced by flickering lights by hybridizing this BCI with a "brain switch," which could allow people to turn the SSVEP system on or off using a second type of brain activity when they do not wish to control the orthosis. We also hope to validate this approach with people with tetraplegia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2010.2076364

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 16

  1. 10.1088/1741-2560/6/4/046002 · DOI · Paper page
  2. 10.1109/TNSRE.2005.847369 · DOI · Paper page
  3. engen, 1968, Instructional Manual for a Reciprocal Wrist Extension-Finger Flexion Orthosis
  4. 10.1088/1741-2560/2/4/008 · DOI · Paper page
  5. 10.1515/BMT.2006.011 · DOI
  6. 10.1109/TNSRE.2003.814433 · DOI · Paper page
  7. 10.1088/1741-2560/7/2/026007 · DOI · Paper page
  8. pfurtscheller, 2009, Could the beta rebound in the EEG be suitable to realize a “brain switch”?, Clin Neurophysiol, 120, 24, 10.1016/j.clinph.2008.09.027 · DOI · Paper page
  9. vora, 2004, a p300 brain computer interface for robot arm control, Soc Neurosci
  10. 10.1016/S0304-3940(02)00119-2 · doi:10.1016/s0304-3940(02)00119-2
  11. 10.1109/TNSRE.2009.2039495 · DOI · Paper page
  12. linortner, 2009, HCI Int 2009Posters, 716
  13. 10.1109/TNSRE.2010.2040837 · DOI · Paper page
  14. mller-putz, 2008, Comparison of DFT and lock-in amplifier features and search for optimal electrode positions in SSVEP-based BCI, J Neurosci Methods, 168, 174, 10.1016/j.jneumeth.2007.09.024 · DOI
  15. 10.1007/BF02345459 · DOI
  16. yan, 2009, a half-field stimulation pattern for ssvep-based brain-computer interface, Conf Proc IEEE Eng Med Biol Soc, 6461

Cited by

See all 281

Metadata

Authors
Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2011-02
Volume
19
Issue
1
Pages
1-5
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2122366741
Cited by
281
References
3
FWCI
9.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia. https://app.cochat.ai/papers/10.1109/tnsre.2010.2076364
The paper
Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G. (2011). An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2010.2076364

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.