The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia
Abstract
Brain-computer interface (BCI) systems allow people to send messages or commands without moving, and hence can provide an alternative communication and control channel for people with limited motor function. In this study, we demonstrate a BCI system for orthosis control. Our BCI was asynchronous, meaning that subjects could move the orthosis whenever they wanted, instead of pacing themselves to external cues. Seven subjects each performed two tasks with a BCI that relied on steady state visual evoked potentials (SSVEPs). Although none of the subjects had any training, six subjects showed good control with a positive predictive value (PPV) higher than 60%. The overall PPV for all subjects reached 78% ±10%. However, the false positive rate was high, and some subjects dislike the flickering lights required in SSVEP BCIs. In follow-up work, we hope to reduce both the false positive rate and the annoyance produced by flickering lights by hybridizing this BCI with a "brain switch," which could allow people to turn the SSVEP system on or off using a second type of brain activity when they do not wish to control the orthosis. We also hope to validate this approach with people with tetraplegia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Self-citationBrain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
Self-citationBCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344
Self-citation
Research works printed but not linked: 16
- 10.1088/1741-2560/6/4/046002 · DOI · Paper page
- 10.1109/TNSRE.2005.847369 · DOI · Paper page
- engen, 1968, Instructional Manual for a Reciprocal Wrist Extension-Finger Flexion Orthosis
- 10.1088/1741-2560/2/4/008 · DOI · Paper page
- 10.1515/BMT.2006.011 · DOI
- 10.1109/TNSRE.2003.814433 · DOI · Paper page
- 10.1088/1741-2560/7/2/026007 · DOI · Paper page
- pfurtscheller, 2009, Could the beta rebound in the EEG be suitable to realize a “brain switch”?, Clin Neurophysiol, 120, 24, 10.1016/j.clinph.2008.09.027 · DOI · Paper page
- vora, 2004, a p300 brain computer interface for robot arm control, Soc Neurosci
- 10.1016/S0304-3940(02)00119-2 · doi:10.1016/s0304-3940(02)00119-2
- 10.1109/TNSRE.2009.2039495 · DOI · Paper page
- linortner, 2009, HCI Int 2009Posters, 716
- 10.1109/TNSRE.2010.2040837 · DOI · Paper page
- mller-putz, 2008, Comparison of DFT and lock-in amplifier features and search for optimal electrode positions in SSVEP-based BCI, J Neurosci Methods, 168, 174, 10.1016/j.jneumeth.2007.09.024 · DOI
- 10.1007/BF02345459 · DOI
- yan, 2009, a half-field stimulation pattern for ssvep-based brain-computer interface, Conf Proc IEEE Eng Med Biol Soc, 6461
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B. (2016) · Scientific Reports · doi:10.1038/srep38565 · Cited by 484
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
Neural interfaces for the brain and spinal cord—restoring motor function
Jackson, A., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 253
Metadata
- Authors
- Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-02
- Volume
- 19
- Issue
- 1
- Pages
- 1-5
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2122366741
- Cited by
- 281
- References
- 3
- FWCI
- 9.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia. https://app.cochat.ai/papers/10.1109/tnsre.2010.2076364
- The paper
- Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G. (2011). An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2010.2076364
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.