Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper extends a previously developed level- ground walking control methodology to enable an above knee amputee to walk up slopes using a powered knee and ankle prosthesis. Experimental results corresponding to walking on level ground and two different slope angles (5 (°) and 10 (°)) with the powered prosthesis using the control method are compared to walking under the same conditions with a passive prosthesis. The data indicate that the powered prosthesis with the upslope walking controller is able to reproduce several kinematic characteristics of healthy upslope walking that the passive prosthesis does not (such as knee flexion after heel strike and a powered ankle plantarflexion during push-off). Finally, results are shown that demonstrate the ability of the prosthesis to generate a slope estimate, which is in turn utilized to adapt the underlying control parameters to the corresponding slope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How Many Steps/Day Are Enough?: Preliminary Pedometer Indices for Public Health
Tudor-Locke, C., & Bassett, D. R. (2004) · Sports Medicine · doi:10.2165/00007256-200434010-00001 · Cited by 2,054
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
The biomechanics and motor control of human gait: Normal, elderly, and pathological
Brand, R. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90236-t · Cited by 1,103
The biomechanics and motor control of human gait
Winter, D. A. (1987) · University of Waterloo Press eBooks · Cited by 767
Design and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
Self-citationPowered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Gait dynamics on an inclined walkway
McIntosh, A. S., Beatty, K. T., Dwan, L. N., & Vickers, D. R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.07.025 · Cited by 384
Preliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis
Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2032688 · Cited by 298
Self-citationAu, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Bellman, R. D., Holgate, M. A., & Sugar, T. G. (2008) · 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2008.4762887 · Cited by 163
Holgate, M. A., Bohler, A. W., & Sugar, T. G. (2008) · 2022 9th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762859 · Cited by 56
AN AUTONOMOUS CONTROL SYSTEM FOR A PROSTHETIC FOOT ANKLE
Svensson, W. (2006) · IFAC Proceedings Volumes · doi:10.3182/20060912-3-de-2911.00147 · Cited by 21
Foot and Ground Measurements Using Portable Sensors
Svensson, W., & Holmberg, U. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501139 · Cited by 18
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“This information has also been used to trigger an activity mode transition [107-110,112,113].”
InfluentialA decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Self-citationQuintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
“The configuration process for a powered knee–ankle prosthesis capable of navigating ramps [9] and stairs [13] can last several hours with a team of expert researchers [14].”
Design and clinical implementation of an open-source bionic leg
Azocar, A. F., Mooney, L. M., Duval, J.-F., Simon, A. M., Hargrove, L. J., & Rouse, E. J. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00619-3 · Cited by 223
Gregg, R. D., Lenzi, T., Hargrove, L. J., & Sensinger, J. W. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2014.2361937 · Cited by 218
Metadata
- Authors
- Sup, F., Varol, H. A., & Goldfarb, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-02
- Volume
- 19
- Issue
- 1
- Pages
- 71-78
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2134208106
- Cited by
- 283
- References
- 13
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.