Hand Spring Operated Movement Enhancer (HandSOME): A Portable, Passive Hand Exoskeleton for Stroke Rehabilitation
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Stroke patients often have flexor hypertonia and finger extensor weakness, which makes it difficult to open their affected hand for functional grasp. Because of this impairment, hand rehabilitation after stroke is essential for restoring functional independent lifestyles. The goal of this study is to develop a passive, lightweight, wearable device to assist with hand function during performance of activities of daily living. The device, Hand Spring Operated Movement Enhancer (HandSOME), assists with opening the patient's hand using a series of elastic cords that apply extension torques to the finger joints and compensates for the flexor hypertonia. Device design and calibration are described as well as functional and usability testing with stroke subjects with a wide range of hand impairments. In initial testing with eight stroke subjects with finger flexor hypertonia, use of the HandSOME significantly increased range of motion and functional ability (p=0.002) . There was some decrease in grip strength with the HandSOME device at the subject's ideal setting, however this was not statistically significant (p=0.167) and did not seem to have a significant effect on function. Overall HandSOME shows promise as a training tool to facilitate repetitive task practice for improving hand function in stroke patients. HandSOME can be used as part of a home-based therapy program, or as an orthotic for replacing lost function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564 · cited 2×
“uated with the Fugl–Meyer Assessment [22].”
Duncan, P. W., Bode, R. K., Min Lai, S., & Perera, S. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00035-2 · Cited by 908 · cited 1×
“At three months poststroke, only 12% of stroke survivors report no difficulty with hand function and 38% of survivors reported major difficulty with hand function [1].”
New treatments in neurorehabiliation founded on basic research
Taub, E., Uswatte, G., & Elbert, T. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn754 · Cited by 641 · cited 1×
“Repetitive use of the affected limb is an effective way to improve motor function [2].”
Intersegmental coordination during reaching at natural visual objects
Jeannerod, M. (1981) · Attention and performance · Cited by 630
The Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570 · cited 1×
“Many of these actively actuated devices utilize internal grasp structures [3]–[5], but this diminishes the possibility of use with real world objects, and can limit range of motion (ROM).”
Desrosiers, J., Bravo, G., Hébert, R., Dutil, É., & Mercier, L. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90130-9 · Cited by 522 · cited 1×
“The HandSOME device’s capacity to increase performance of functional activities was measured in a task modeled after the Box-and-Blocks task [24].”
Timmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
Gregson, J. M., Leathley, M., Moore, A. P., Sharma, A. K., Smith, T. L., & Watkins, C. L. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90053-9 · Cited by 427 · cited 2×
“Muscle tone was measured in the finger flexors with the Modified Ashworth Scale [23].”
Housman, S. J., Scott, K. M., & Reinkensmeyer, D. J. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308331148 · Cited by 369 · cited 1×
“[10], and passive exoskeleton rehabilitation devices [11], [12].”
Rehabilitation of arm function after stroke. Literature review
Oujamaa, L., Relave, I., Froger, J., Mottet, D., & Pelissier, J.-Y. (2009) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2008.10.003 · Cited by 350 · cited 1×
“Therapists currently emphasize functional training for many types of stroke patients, and this practice is supported by recent reviews [26], [27].”
Cavina-Pratesi, C., Monaco, S., Fattori, P., Galletti, C., McAdam, T. D., Quinlan, D. J., Goodale, M. A., & Culham, J. C. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.2023-10.2010 · Cited by 324 · cited 1×
“Primate and brain imaging studies in humans are beginning to isolate the neural substrate that underlies this coordination [35], [ 36 ].”
Functional relationships between grasp and transport components in a prehension task
Marteniuk, R. G., Leavitt, J. L., MacKenzie, C. L., & Athènes, S. (1990) · Human Movement Science · doi:10.1016/0167-9457(90)90025-9 · Cited by 311 · cited 1×
“normal subjects [32], [33] that is impaired after stroke [34].”
Robot-assisted rehabilitation of hand function
Balasubramanian, S., Klein, J., & Burdet, E. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32833e99a4 · Cited by 287 · cited 1×
“rent actively powered external grasp devices are exceedingly bulky and limit the type of grasp and hand orientation that can be used for task practice (see [6] for a complete review).”
Cirstea, M. C., & Levin, M. F. (2007) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968306298414 · Cited by 251 · cited 1×
“Another study showed that when training stroke subjects on a pointing task, outcomes were better when subjects were given feedback on shoulder and elbow kinematics rather than feedback on endpoint errors [29].”
Influence of object position and size on human prehension movements
Paulignan, Y., Frak, V. G., Toni, I., & Jeannerod, M. (1997) · Experimental Brain Research · doi:10.1007/pl00005631 · Cited by 210 · cited 1×
“normal subjects [32], [33] that is impaired after stroke [34].”
Kamper, D. G., Harvey, R. L., Suresh, S., & Rymer, W. Z. (2003) · Muscle & Nerve · doi:10.1002/mus.10443 · Cited by 209 · cited 1×
“examined the torque required to extend hypertonic finger joints and found a nearly linear relationship between metacarpophalangeal (MCP) joint extension angle and applied extension torque [16], [17].”
ERGONOMIC DESIGN FOR PEOPLE AT WORK
Rodgers, S. H. (2018) · Cited by 207
A Haptic Knob for Rehabilitation of Hand Function
Lambercy, O., Dovat, L., Gassert, R., Burdet, E., Teo, C. L., & Milner, T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903913 · Cited by 196 · cited 1×
“Many of these actively actuated devices utilize internal grasp structures [3]–[5], but this diminishes the possibility of use with real world objects, and can limit range of motion (ROM).”
Fischer, H., Stubblefield, K., Kline, T., Luo, X., Kenyon, R., & Kamper, D. (2007) · Topics in Stroke Rehabilitation · doi:10.1310/b662-3140-7q20-2778 · Cited by 193
Lang, C. E., & Schieber, M. H. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00805.2003 · Cited by 190 · cited 1×
“This design will allow stroke survivors with lost independent joint control to obtain and hopefully retrain proper inter-joint coordination in grasp [19], [20].”
Krebs, H. I., Mernoff, S., Fasoli, S. E., Hughes, R., Stein, J., & Hogan, N. (2008) · NeuroRehabilitation · doi:10.3233/nre-2008-23108 · Cited by 139 · cited 1×
“showed that training of robot-assisted reaching movements produced greater reductions in shoulder-elbow impairment than a time-matched dose of functional robotic training consisting of combined reach and grasp tasks [28].”
Design and Characterization of Hand Module for Whole-Arm Rehabilitation Following Stroke
Masia, L., Krebs, H. I., Cappa, P., & Hogan, N. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901928 · Cited by 124
Prange, G. B., Jannink, M. J. A., Stienen, A. H. A., van der Kooij, H., IJzerman, M. J., & Hermens, H. J. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968308328720 · Cited by 102 · cited 1×
“These devices provide arm weight compensation using overhead pulley systems [7], [8], spring-based arm orthotics attached to wheelchairs [9],”
MethodEncoding of Reach and Grasp by Single Neurons in Premotor Cortex Is Independent of Recording Site
Stark, E., Asher, I., & Abeles, M. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01328.2006 · Cited by 93 · cited 1×
“Primate and brain imaging studies in humans are beginning to isolate the neural substrate that underlies this coordination [35], [36].”
Dampace: Design of an Exoskeleton for Force-Coordination Training in Upper-Extremity Rehabilitation
Stienen, A. H. A., Hekman, E. E. G., Prange, G. B., Jannink, M. J. A., Aalsma, A. M. M., van der Helm, F. C. T., & van der Kooij, H. (2009) · Journal of Medical Devices · doi:10.1115/1.3191727 · Cited by 92 · cited 1×
“[10], and passive exoskeleton rehabilitation devices [11], [12].”
Limited fine hand use after stroke and its association with other disabilities
Welmer, A., Holmqvist, L. W., & Sommerfeld, D. K. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0218 · Cited by 90 · cited 1×
“for ADL due to loss of isolated individual finger movement, finger proprioception, and fine touch sensation [18].”
Patterns of Impairment in Digit Independence After Subcortical Stroke
Raghavan, P., Petra, E., Krakauer, J. W., & Gordon, A. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00873.2005 · Cited by 88 · cited 1×
“This design will allow stroke survivors with lost independent joint control to obtain and hopefully retrain proper inter-joint coordination in grasp [19], [20].”
Orthotic aided training of the paretic upper limb in chronic stroke: Results of a phase 1 trial
Farrell, J. F., Hoffman, H. B., Snyder, J. L., Giuliani, C., & Bohannon, R. W. (2007) · Neurorehabilitation · doi:10.3233/nre-2007-22204 · Cited by 75 · cited 1×
“agement therapy [13].”
Ratcliff, G. G. (1979) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(79)90104-7 · Cited by 52
Freebal: Design of a Dedicated Weight-Support System for Upper-Extremity Rehabilitation
Stienen, A. H. A., Hekman, E. E. G., Prange, G. B., Jannink, M. J. A., van der Helm, F. C. T., & van der Kooij, H. (2009) · Journal of Medical Devices · doi:10.1115/1.4000493 · Cited by 34
Hemisphere Specific Impairments in Reach-to-Grasp Control After Stroke: Effects of Object Size
Tretriluxana, J., Gordon, J., Fisher, B. E., & Winstein, C. J. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968309332733 · Cited by 32 · cited 1×
“normal subjects [32], [33] that is impaired after stroke [34].”
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
“Brokaw et al. [164] presented a passive linkage-based device able to provide extension moments to the finger joints to compensate for finger flexor hypertonia.”
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
A Review of Active Hand Exoskeletons for Rehabilitation and Assistance
du Plessis, T., Djouani, K., & Oosthuizen, C. (2021) · Robotics · doi:10.3390/robotics10010040 · Cited by 218
“SCRIPT and SaeboGlove are devices where individual finger movement can be accomplished, but the HandSOME device has been designed to combine the movement of the index, middle, ring, and little fingers, and the thumb is independent of the rest.”
MethodYap, H. K., Lim, J. H., Nasrallah, F., & Yeow, C.-H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00547 · Cited by 195
“45 N/mm) was chosen to match the elastic modulus of the elastic cords described in previous devices that allow the patients to flex their fingers voluntarily and provide assistance in the hand opening (Brokaw et al., 2011).”
MethodResultInfluentialHand Rehabilitation Robotics on Poststroke Motor Recovery
Yue, Z., Zhang, X., & Wang, J. (2017) · Behavioural Neurology · doi:10.1155/2017/3908135 · Cited by 195
“Robots of passive training modality are usually controlled by a position to do repetitive training, in which the robots move the hand from the start position to the end position and then move back [75, 108].”
BackgroundInfluential
Metadata
- Authors
- Brokaw, E. B., Black, I., Holley, R. J., & Lum, P. S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-08
- Volume
- 19
- Issue
- 4
- Pages
- 391-399
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2106818390
- Cited by
- 197
- References
- 31
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.