CoChat

An Analysis of the Accuracy of Wearable Sensors for Classifying the Causes of Falls in Humans

Open access
Aziz, Omar, Robinovitch, Stephen N. · 2011 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Falls are the number one cause of injury in older adults. Wearable sensors, typically consisting of accelerometers and/or gyroscopes, represent a promising technology for preventing and mitigating the effects of falls. At present, the goal of such "ambulatory fall monitors" is to detect the occurrence of a fall and alert care providers to this event. Future systems may also provide information on the causes and circumstances of falls, to aid clinical diagnosis and targeting of interventions. As a first step towards this goal, the objective of the current study was to develop and evaluate the accuracy of a wearable sensor system for determining the causes of falls. Sixteen young adults participated in experimental trials involving falls due to slips, trips, and "other" causes of imbalance. Three-dimensional acceleration data acquired during the falling trials were input to a linear discriminant analysis technique. This routine achieved 96% sensitivity and 98% specificity in distinguishing the causes of a falls using acceleration data from three markers (left ankle, right ankle, and sternum). In contrast, a single marker provided 54% sensitivity and two markers provided 89% sensitivity. These results indicate the utility of a three-node accelerometer array for distinguishing the cause of falls.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2011.2162250

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 97

Metadata

Authors
Aziz, O., & Robinovitch, S. N.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2011-12
Volume
19
Issue
6
Pages
670-676
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2040879679
Cited by
97
References
2
FWCI
6.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Analysis of the Accuracy of Wearable Sensors for Classifying the Causes of Falls in Humans. https://app.cochat.ai/papers/10.1109/tnsre.2011.2162250
The paper
Aziz, O., & Robinovitch, S. N. (2011). An Analysis of the Accuracy of Wearable Sensors for Classifying the Causes of Falls in Humans. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2162250

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.