Haptic Feedback Enhances Grip Force Control of sEMG-Controlled Prosthetic Hands in Targeted Reinnervation Amputees
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In this study, we hypothesized that haptic feedback would enhance grip force control of surface electromyography (sEMG)-controlled prosthetic hands for targeted reinnervation (TR) amputees. A new miniature haptic device, a tactor, that can deliver touch, pressure, shear, and temperature sensation, allows modality-matching haptic feedback. TR surgery that creates sensory regions on the patient's skin that refer to the surface of the missing limb allows somatotopic-matching haptic feedback. This paper evaluates the hypothesis via an sEMG-controlled virtual prosthetic arm operated by TR amputees under diverse haptic feedback conditions. The results indicate that the grip force control is significantly enhanced via the haptic feedback. However, the simultaneous display of two haptic channels (pressure and shear) does not enhance, but instead degrades, grip force control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
MANUAL MOTOR PERFORMANCE IN A DEAFFERENTED MAN
ROTHWELL, J. C., TRAUB, M. M., DAY, B. L., OBESO, J. A., THOMAS, P. K., & MARSDEN, C. D. (1982) · Brain · doi:10.1093/brain/105.3.515 · Cited by 862
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147
Schultz, A. E., Marasco, P. D., & Kuiken, T. A. (2009) · Brain Research · doi:10.1016/j.brainres.2008.11.039 · Cited by 58
Cited by
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Towards Wearability in Fingertip Haptics: A 3-DoF Wearable Device for Cutaneous Force Feedback
Prattichizzo, D., Chinello, F., Pacchierotti, C., & Malvezzi, M. (2013) · IEEE Transactions on Haptics · doi:10.1109/toh.2013.53 · Cited by 292
A wireless haptic interface for programmable patterns of touch across large areas of the skin
Jung, Y. H., Yoo, J.-Y., Vázquez-Guardado, A., Kim, J.-H., Kim, J.-T., Luan, H., Park, M., Lim, J., Shin, H.-S., Su, C.-J., et al. (2022) · Nature Electronics · doi:10.1038/s41928-022-00765-3 · Cited by 263
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“However, in a study undertaken by Kim and Colgate [17], their subject showed a lower performance picking up a virtual object when receiving shear forces through vibrations at the same time as receiving pressure feedback on grasping force, although this experiment was only performed with one subject with five sets of t…”
BackgroundMethodResultInfluentialClemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
Metadata
- Authors
- Kim, K., & Colgate, J. E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-11
- Volume
- 20
- Issue
- 6
- Pages
- 798-805
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2070851291
- Cited by
- 149
- References
- 6
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Haptic Feedback Enhances Grip Force Control of sEMG-Controlled Prosthetic Hands in Targeted Reinnervation Amputees. https://app.cochat.ai/papers/10.1109/tnsre.2012.2206080
- The paper
- Kim, K., & Colgate, J. E. (2012). Haptic Feedback Enhances Grip Force Control of sEMG-Controlled Prosthetic Hands in Targeted Reinnervation Amputees. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2012.2206080
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.