Behavioral Demonstration of a Somatosensory Neuroprosthesis
The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
Abstract
Tactile sensation is critical for effective object manipulation, but current prosthetic upper limbs make no provision for delivering somesthetic feedback to the user. For individuals who require use of prosthetic limbs, this lack of feedback transforms a mundane task into one that requires extreme concentration and effort. Although vibrotactile motors and sensory substitution devices can be used to convey gross sensations, a direct neural interface is required to provide detailed and intuitive sensory feedback. In light of this, we describe the implementation of a somatosensory prosthesis with which we elicit, through intracortical microstimulation (ICMS), percepts whose magnitude is graded according to the force exerted on the prosthetic finger. Specifically, the prosthesis consists of a sensorized finger, the force output of which is converted into a regime of ICMS delivered to primary somatosensory cortex through chronically implanted multi-electrode arrays. We show that the performance of animals (Rhesus macaques) on a tactile task is equivalent whether stimuli are delivered to the native finger or to the prosthetic finger.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrodes inserted into the sensory cortex of nonhuman primates (13) have demonstrated localized sensory feedback.”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [13]
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816 · cited 1×
“2244616 of limb amputation or spinal cord injury resulting in para- or tetraplegia often mitigate their loss with prosthetic devices to assist in performing the activities of daily living (ADL) [1]–[5].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“One approach consists of implanting multielectrode arrays in cortical regions involved in motor planning and control, recording the neuronal activity elicited over the array during various motor tasks, and developing algorithms that decode motor intention from this neuronal activity [7], [8], [17].”
BackgroundReal-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487 · cited 2×
“Near-instantaneous cortical control of a virtual limb is now possible, greatly reducing or eliminating the need for extensive training in the use of the device [7], [10], [15], [18].”
BackgroundInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Self-citationReal-time control of a robot arm using simultaneously recorded neurons in the motor cortex
Chapin, J. K., Moxon, K. A., Markowitz, R. S., & Nicolelis, M. A. L. (1999) · Nature Neuroscience · doi:10.1038/10223 · Cited by 1,164 · cited 2×
“Near-instantaneous cortical control of a virtual limb is now possible, greatly reducing or eliminating the need for extensive training in the use of the device [7], [10], [15], [18].”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Research works printed but not linked: 3
- 10.1038/nature10489 · DOI · Paper page
- 10.1038/32891 · DOI · Paper page
- 1981, Organization of Somatosensory Cortex in Primates (The Organization of the Cerebral Cortex Proceedings of Neurosciences Research Program Colloquium)
Cited by
Items 101–117 of 117
Detecting and comparing the onset of self-paced and cue-based finger movements from EEG signals
Belić, J. J., & Savić, A. M. (2015) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec.2015.7332717 · Cited by 1
Intracortical microstimulation for tactile feedback in awake behaving rats
Devecıoğlu, İ., Öztürk, S., & Güçlü, B. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00013-7 · Cited by 1
Costa, V., Suassuna, A. D. O. B., Galdino, L. G. Z., & Kunicki, A. C. (2022) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-70601-2_330 · Cited by 1
Brain-Machine Interface: Overview
Oweiss, K. G. (2020) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_783-2 · Cited by 1
Brain-Machine Interface: Overview
Oweiss, K. G. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_783-1 · Cited by 1
Rosenthal, I. A., Bashford, L., Bjånes, D. A., Pejsa, K., Lee, B., Liu, C. Y., & Andersen, R. A. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.05.13.593529 · Cited by 1
“This suggests that ICMS can be a valid substitute for physical touches in tactile tasks, not only in terms of behavioral performance (Berg et al., 2013; Klaes et al., 2014; Tabot et al., 2015), but also in terms of how the stimulation is processed within the somatosensory system.”
BackgroundTactile feedback for myoelectric forearm prostheses
Witteveen, H. J. B. (2013) · doi:10.3990/1.9789036535885 · Cited by 2
Balasubramanian, K., & Hatsopoulos, N. G. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_705
Self-citationDevecıoğlu, İ., & Güçlü, B. (2015) · National Biomedical Engineering Meeting · doi:10.1109/biyomut.2015.7369454
Tactile Sensory Responses in Motor Cortex and Their Relevance to Brain-Machine Interfaces.
Schroeder, K. E. (2016) · Deep Blue (University of Michigan)
Devecıoğlu, İ., & Güçlü, B. (2020) · Journal of Computational Neuroscience · doi:10.1007/s10827-020-00751-8
“Understanding the learning process within this time period is important not only from a basic scientific point of view, but also because of the increased use of experimental animals in neural engineering applications (Berg et al. 2013; Chapin et al. 1999; Kocatürk et al. 2010; London et al. 2008; Tabot et al. 2013).”
BackgroundDevelopment of multi-degree-of-freedom hand prosthesis cover with sensory recognition
Jung, S. Y., Hyo Jong, Y. O. O., Kim, S. G., Park, S.-H., Jin Kuk, P. A. R. K., Kim, J., & Shin, H. (2021) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.21-00076
“…recognition studies, Wettels et al. (2009) developed tactile sensing mechanisms using air pressure to measure the grip force of a prosthetic hand, and Berg et al. (2013) and Abd et al. (2020) developed tactile sensing mechanisms using force sensors and liquid metal tactile sensors, respectively.”
BackgroundBrain-Machine Interface: Overview
Oweiss, K. G. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_783
Balasubramanian, K., & Hatsopoulos, N. G. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_705
Self-citationBrain-Machine Interface: Overview
Oweiss, K. G. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_783
Balasubramanian, K., & Hatsopoulos, N. G. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_705-1
Self-citationGrundfest, D., Kim, K., Wang, Q., Yonza, A. K. I., Podsiadlo, J. T., Tao, L., zhang, X., Kucharz, K., Zhang, Y., Han, A., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae829c · Cited by 3
“Electrical stimulation consisted of cathodic-leading biphasic pulses (200 µ s per phase, without inter-pulse interval, figure 1(D)), with stimulation duration of 500 ms, which is commonly used in preclinical ICMS studies to evoke transient neuronal responses and artificial sensory percept [58–60].”
Metadata
- Authors
- Berg, J. A., Dammann, J. F., Tenore, F. V., Tabot, G. A., Boback, J. L., Manfredi, L. R., Peterson, M. L., Katyal, K. D., Johannes, M. S., Makhlin, A., Wilcox, R., Franklin, R. K., Vogelstein, R. J., Hatsopoulos, N. G., & Bensmaia, S. J.
- Affiliations
- University of Chicago (US)
- Johns Hopkins University (US)
- Blackrock Microsystems (United States) (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-05
- Volume
- 21
- Issue
- 3
- Pages
- 500-507
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2048657081
- Cited by
- 119
- References
- 33
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 5 · 2022: 9 · 2021: 9 · 2020: 9 · 2019: 7 · 2018: 5 · 2017: 7 · 2016: 18 · 2015: 15 · 2014: 20 · 2013: 9
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (NS-18787, R01NS018787)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- intracortical microstimulation, tactile feedback, upper limb prosthesis, primary somatosensory cortex, microelectrode arrays, rhesus monkeys, neural interfaces
- MeSH terms
- Animals, Artificial Limbs, Behavior, Animal, Biofeedback, Psychology, Equipment Design, Evoked Potentials, Somatosensory, Fingers, Humans, Macaca mulatta, Male, Movement, Robotics, Touch, Transducers, Equipment Failure Analysis, Deep Brain Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.