Extracting Signals Robust to Electrode Number and Shift for Online Simultaneous and Proportional Myoelectric Control by Factorization Algorithms
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Previous research proposed the extraction of myoelectric control signals by linear factorization of multi-channel electromyogram (EMG) recordings from forearm muscles. This paper further analyses the theoretical basis for dimensionality reduction in high-density EMG signals from forearm muscles. Moreover, it shows that the factorization of muscular activation patterns in weights and activation signals by non-negative matrix factorization (NMF) is robust with respect to the channel configuration from where the EMG signals are obtained. High-density surface EMG signals were recorded from the forearm muscles of six individuals. Weights and activation signals extracted offline from 10 channel configurations with varying channel numbers (6, 8, 16, 192 channels) were highly similar. Additionally, the method proved to be robust against electrode shifts in both transversal and longitudinal direction with respect to the muscle fibers. In a second experiment, six subjects directly used the activation signals extracted from high-density EMG for online goal-directed control tasks involving simultaneous and proportional control of two degrees-of-freedom of the wrist. The synergy weights for this control task were extracted from a reference configuration and activation signals were calculated online from the reference configuration as well as from the two shifted configurations, simulating electrode shift. Despite the electrode shift, the task completion rate, task completion time, and execution efficiency were generally not statistically different among electrode configurations. Online performances were also mostly similar when using either 6, 8, or 16 EMG channels. The robustness of the method to the number and location of channels, proved both offline and online, indicates that EMG signals recorded from forearm muscles can be approximated as linear instantaneous mixtures of activation signals and justifies the use of linear factorization algorithms for extracting, in a minimally supervised way, control signals for simultaneous multi-degree of freedom prosthesis control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ALGORITHMS FOR NON-NEGATIVE MATRIX FACTORIZATION
Seung, D., & Lee, L.-W. (2001) · Cited by 4,753
Combinations of muscle synergies in the construction of a natural motor behavior
d'Avella, A., Saltiel, P., & Bizzi, E. (2003) · Nature Neuroscience · doi:10.1038/nn1010 · Cited by 1,344 · cited 2×
“In both cases, the muscular activation pattern estimated by multiplying the channel weighting matrix and the activation signals was compared with the recorded pattern by the multivariate coefficient of determination [15].”
BackgroundMethodScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 1×
“nition approach [1], which is based on the fact that amputees”
BackgroundThe construction of movement by the spinal cord
Tresch, M. C., Saltiel, P., & Bizzi, E. (1999) · Nature Neuroscience · doi:10.1038/5721 · Cited by 617 · cited 2×
“on the muscle synergy model [8], which assumes that move-”
BackgroundNeuromechanics of muscle synergies for posture and movement
Ting, L. H., & McKay, J. L. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2008.01.002 · Cited by 514
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508 · cited 1×
“open–close, they are the most desired and functionally important missing functions in commercial prostheses for transradial amputees [17].”
BackgroundCheung, V. C. K., d'Avella, A., Tresch, M. C., & Bizzi, E. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4904-04.2005 · Cited by 492 · cited 5×
“Channel weighting vectors extracted from the reference, shiftT, and shiftL configurations were compared to those extracted from the complete one through the NDP between the channel weighting vectors of the reduced configurations and those obtained from the complete configuration, by selecting the channels (rows of ) i…”
BackgroundMethodInfluentialJiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450 · cited 9×
“During the calibration phase, a channel weighting matrix was extracted with the DOF-NMF [11] from the EMG signals obtained from the reference configuration.”
BackgroundMethodInfluentialSelf-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citationYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287 · cited 4×
“are not robust to electrode shifts [2], which may occur during”
BackgroundInfluentialMuceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285 · cited 1×
“Both linear [4] and nonlinear approaches [5], [6] have”
BackgroundSelf-citationHargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 4×
“Sixteen channels were selected for comparison with our previous work [18].”
MethodResultInfluentialSelf-citationLucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253 · cited 1×
“In all these studies, electrode placement was not targeted to specificmuscles but approximately equi-spaced around the forearm circumference with the intention of avoiding the need for location optimization and in agreement with pattern recognition studies [2], [21].”
Self-citationModulation of Phasic and Tonic Muscle Synergies With Reaching Direction and Speed
d'Avella, A., Fernandez, L., Portone, A., & Lacquaniti, F. (2008) · Journal of Neurophysiology · doi:10.1152/jn.01377.2007 · Cited by 248 · cited 2×
“Muscle activation patterns are generally estimated from the envelopes of the EMG signals [13]–[16] and this will be also done in this study.”
MethodResultJiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181 · cited 1×
“Both linear [4] and nonlinear approaches [5], [6] have”
BackgroundSelf-citationMuceli, S., Boye, A. T., d'Avella, A., & Farina, D. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00559.2009 · Cited by 177 · cited 8×
“Four channel weighting vectors were also extracted from the single DOF movement datasets (series 1 and 2) with the DOF-wise NMF algorithm proposed in [11] and used to describe the full dataset (series 1–3) by calculating the activation signals with the non-negative reconstruction algorithm (NNR) [13].”
BackgroundMethodInfluentialSelf-citationBlind Separation of Linear Instantaneous Mixtures of Nonstationary Surface Myoelectric Signals
Farina, D., Févotte, C., Doncarli, C., & Merletti, R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828048 · Cited by 102 · cited 1×
“This is consistent with the observation that synergies do not substantially change when eliminating from the analysis the muscles mostly affected by potential crosstalk [16] as well as with results on blind source separation of forearm muscle signals for reducing crosstalk [12], [22].”
ResultSelf-citationEvidence of muscle synergies during human grasping
Castellini, C., & van der Smagt, P. (2013) · Biological Cybernetics · doi:10.1007/s00422-013-0548-4 · Cited by 75 · cited 1×
“The exploitation of the synergy model for myoelectric control is relatively novel [7], [11], [20].”
BackgroundSimultaneous and proportional control of 2D wrist movements with myoelectric signals
Hahne, J. M., Rehbaum, H., Bießmann, F., Meinecke, F. C., Müller, K. R., Jiang, N., Farina, D., & Parra, L. C. (2012) · Machine learning for signal processing ... · doi:10.1109/mlsp.2012.6349712 · Cited by 49 · cited 1×
“Both linear [4] and nonlinear approaches [5], [6] have”
BackgroundSelf-citationRehbaum, H., Jiang, N., Paredes, L. P., Amsuess, S., Graimann, B., & Farina, D. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346187 · Cited by 45 · cited 21×
“The figure confirms a functional separation of the DOFs, as expected since weights were extracted by the DOFwise algorithm.”
BackgroundMethodInfluentialSelf-citation
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationBi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Muceli, S., Jiang, N., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 623-633
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2021320602
- Cited by
- 172
- References
- 21
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.