The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Intuitive, Online, Simultaneous, and Proportional Myoelectric Control Over Two Degrees-of-Freedom in Upper Limb Amputees
Abstract
We propose an approach for online simultaneous and proportional myoelectric control of two degrees-of-freedom (DoF) of the wrist, using surface electromyographic signals. The method is based on the nonnegative matrix factorization (NMF) of the wrist muscle activation to extract low-dimensional control signals translated by the user into kinematic variables. This procedure does not need a training set of signals for which the kinematics is known (labeled dataset) and is thus unsupervised (although it requires an initial calibration without labeled signals). The estimated control signals using NMF are used to directly control two DoFs of wrist. The method was tested on seven subjects with upper limb deficiency and on seven able-bodied subjects. The subjects performed online control of a virtual object with two DoFs to achieve goal-oriented tasks. The performance of the two subject groups, measured as the task completion rate, task completion time, and execution efficiency, was not statistically different. The approach was compared, and demonstrated to be superior to the online control by the industrial state-of-the-art approach. These results show that this new approach, which has several advantages over the previous myoelectric prosthetic control systems, has the potential of providing intuitive and dexterous control of artificial limbs for amputees.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In previous studies, investigators have provided prosthetic control signals by interfacing with intact muscles in the residual limb.”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“This strategy has provided reasonable signal amplitude and some control of a prosthetic limb in patients undergoing transradial amputations (24–28).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“Previous studies of simultaneous control of multiple DOFs have focused on controlling the wrist and hand open/closed (26, 28, 30).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Computations Underlying the Execution of Movement: A Biological Perspective
Bizzi, E., Mussa-Ivaldi, F. A., & Giszter, S. (1991) · Science · doi:10.1126/science.1857964 · Cited by 677
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Kuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citation
Research works printed but not linked: 1
- moore, 1920, On the reciprocal of the general algebraic matrix, Bull Am Math Soc, 26, 394
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationComparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D.
- Affiliations
- Bernstein Center for Computational Neuroscience Göttingen (DE)
- Ottobock (Germany) (DE)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 501-510
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2100338757
- Cited by
- 269
- References
- 22
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 16 · 2023: 15 · 2022: 22 · 2021: 28 · 2020: 32 · 2019: 30 · 2018: 21 · 2017: 31 · 2016: 16 · 2015: 23 · 2014: 17
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- GRO (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- myoelectric control, upper limb amputees, two-degree-of-freedom control, surface electromyography, non-negative matrix factorization, proportional control, myoelectric prosthesis
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Amputation, Surgical, Amputees, Artificial Limbs, Biomechanical Phenomena, Calibration, Electromyography, Humans, Male, Middle Aged, Online Systems, Wrist, Upper Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intuitive, Online, Simultaneous, and Proportional Myoelectric Control Over Two Degrees-of-Freedom in Upper Limb Amputees. https://app.cochat.ai/papers/10.1109/tnsre.2013.2278411
- The paper
- Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014). Intuitive, Online, Simultaneous, and Proportional Myoelectric Control Over Two Degrees-of-Freedom in Upper Limb Amputees. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2013.2278411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.