Estimation of Human Ankle Impedance During the Stance Phase of Walking
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Human joint impedance is the dynamic relationship between the differential change in the position of a perturbed joint and the corresponding response torque; it is a fundamental property that governs how humans interact with their environments. It is critical to characterize ankle impedance during the stance phase of walking to elucidate how ankle impedance is regulated during locomotion, as well as provide the foundation for future development of natural, biomimetic powered prostheses and their control systems. In this study, ankle impedance was estimated using a model consisting of stiffness, damping and inertia. Ankle torque was well described by the model, accounting for 98 ±1.2% of the variance. When averaged across subjects, the stiffness component of impedance was found to increase linearly from 1.5 to 6.5 Nm/rad/kg between 20% and 70% of stance phase. The damping component was found to be statistically greater than zero only for the estimate at 70% of stance phase, with a value of 0.03 Nms/rad/kg. The slope of the ankle's torque-angle curve-known as the quasi-stiffness-was not statistically different from the ankle stiffness values, and showed remarkable similarity. Finally, using the estimated impedance, the specifications for a biomimetic powered ankle prosthesis were introduced that would accurately emulate human ankle impedance during locomotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Söderström, T., & Stoica, P. (1988) · Cited by 5,162
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Ljung, L. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1046 · Cited by 3,778
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359 · cited 1×
“For example, passive dynamic walkers are able to “walk” with minimal energy added via ambulation down a slope [43], [44]; low-magnitude negative damping values could provide the energy needed for similar locomotion over level ground.”
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206 · cited 1×
“For example, a series-elastic ankle prosthesis that included a series stiffness tuned to the biological ankle stiffness function could minimize the mechanical work required by an electric motor within a powered prosthesis [46], [47].”
Efficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873 · cited 1×
“For example, passive dynamic walkers are able to “walk” with minimal energy added via ambulation down a slope [43], [44]; low-magnitude negative damping values could provide the energy needed for similar locomotion over level ground.”
Walking Patterns of Normal Men
MURRAY, M. P., DROUGHT, A. B., & KORY, R. C. (1964) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196446020-00009 · Cited by 1,169 · cited 1×
“Previous research spanning many decades has provided a rich knowledge of ankle joint kinematics and kinetics [3]–[6].”
Electromechanical delay in human skeletal muscle under concentric and eccentric contractions
Cavanagh, P. R., & Komi, P. V. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00431022 · Cited by 802 · cited 1×
“The shortest latency reflexes occur at approximately 40 ms following an externally imposed movement [54], [55] and peak muscle force in the triceps surae muscles occurs approximately 60 ms later [56], [57].”
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“An improved understanding of how humans control the impedance of the lower limbs is necessary to optimize the mechanical design and control of P/O devices and is the topic of ongoing biomechanics and neuroscience research [156,194,205-209].”
Proprioception from a neurally controlled lower-extremity prosthesis
Clites, T. R., Carty, M. J., Ullauri, J. B., Carney, M. E., Mooney, L. M., Duval, J.-F., Srinivasan, S. S., & Herr, H. M. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8373 · Cited by 233
Design and clinical implementation of an open-source bionic leg
Azocar, A. F., Mooney, L. M., Duval, J.-F., Simon, A. M., Hargrove, L. J., & Rouse, E. J. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00619-3 · Cited by 223
Self-citationOnline Reinforcement Learning Control for the Personalization of a Robotic Knee Prosthesis
Wen, Y., Si, J., Brandt, A., Gao, X., & Huang, H. H. (2020) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2019.2890974 · Cited by 180
“The first approach is to estimate the control impedance parameters with either a musculoskeletal model [9] or measurements of biological joint impedance [10], [11].”
BackgroundA review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Metadata
- Authors
- Rouse, E. J., Hargrove, L. J., Perreault, E. J., & Kuiken, T. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-07
- Volume
- 22
- Issue
- 4
- Pages
- 870-878
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2099683979
- Cited by
- 207
- References
- 49
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.