Artificial Proprioceptive Feedback for Myoelectric Control
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The typical control of myoelectric interfaces, whether in laboratory settings or real-life prosthetic applications, largely relies on visual feedback because proprioceptive signals from the controlling muscles are either not available or very noisy. We conducted a set of experiments to test whether artificial proprioceptive feedback, delivered noninvasively to another limb, can improve control of a two-dimensional myoelectrically-controlled computer interface. In these experiments, participants were required to reach a target with a visual cursor that was controlled by electromyogram signals recorded from muscles of the left hand, while they were provided with an additional proprioceptive feedback on their right arm by moving it with a robotic manipulandum. Provision of additional artificial proprioceptive feedback improved the angular accuracy of their movements when compared to using visual feedback alone but did not increase the overall accuracy quantified with the average distance between the cursor and the target. The advantages conferred by proprioception were present only when the proprioceptive feedback had similar orientation to the visual feedback in the task space and not when it was mirrored, demonstrating the importance of congruency in feedback modalities for multi-sensory integration. Our results reveal the ability of the human motor system to learn new inter-limb sensory-motor associations; the motor system can utilize task-related sensory feedback, even when it is available on a limb distinct from the one being actuated. In addition, the proposed task structure provides a flexible test paradigm by which the effectiveness of various sensory feedback and multi-sensory integration for myoelectric prosthesis control can be evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 1×
“Non-visual feedback modalities can aid myoelectric control when vision is unavailable, and may help the prosthesis become incorporated into the wearer’s body image [31].”
BackgroundVibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Learning Multisensory Integration and Coordinate Transformation via Density Estimation
Makin, J. G., Fellows, M. R., & Sabes, P. N. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003035 · Cited by 53 · cited 1×
“environment will benefit from the provision of fast, reliable and potentially multi-modal sensory feedback [29], [30].”
Background
Cited by
Soft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“[105] also examined the role of proprioceptive feedback.”
BackgroundTask-Specific somatosensory feedback via cortical stimulation in humans
Cronin, J. A., Wu, J., Collins, K. L., Sarma, D., Rao, R. P. N., Ojemann, J. G., & Olson, J. D. (2016) · IEEE Transactions on Haptics · doi:10.1109/toh.2016.2591952 · Cited by 68
“provided proprioceptive feedback through a robotic manipulandum to increase human performance in amyoelectric-control task [6].”
BackgroundSomatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex
Kirin, S. C., Yanagisawa, T., Oshino, S., Edakawa, K., Tanaka, M., Kishima, H., & Nishimura, Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01019 · Cited by 12
Metadata
- Authors
- Pistohl, T., Joshi, D., Ganesh, G., Jackson, A., & Nazarpour, K.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-05
- Volume
- 23
- Issue
- 3
- Pages
- 498-507
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2067475585
- Cited by
- 56
- References
- 3
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Proprioceptive Feedback for Myoelectric Control. https://app.cochat.ai/papers/10.1109/tnsre.2014.2355856
- The paper
- Pistohl, T., Joshi, D., Ganesh, G., Jackson, A., & Nazarpour, K. (2015). Artificial Proprioceptive Feedback for Myoelectric Control. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2355856
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.