Development of an Environment-Aware Locomotion Mode Recognition System for Powered Lower Limb Prostheses
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper aimed to develop and evaluate an environment-aware locomotion mode recognition system for volitional control of powered artificial legs. A portable terrain recognition (TR) module, consisting of an inertia measurement unit and a laser distance meter, was built to identify the type of terrain in front of the wearer while walking. A decision tree was used to classify the terrain types and provide either coarse or refined information about the walking environment. Then, the obtained environmental information was modeled as a priori probability and was integrated with a neuromuscular-mechanical-fusion-based locomotion mode (LM) recognition system. The designed TR module and environmental-aware LM recognition system was evaluated separately on able-bodied subjects and a transfemoral amputee online. The results showed that the TR module provided high quality environmental information: TR accuracy is above 98% and terrain transitions are detected over 500 ms before the time required to switch the prosthesis control mode. This enabled smooth locomotion mode transitions for the wearers. The obtained environmental information further improved the performance of LM recognition system, regardless of whether coarse or refined information was used. In addition, the environment-aware LM recognition system produced reliable online performance when the TR output was relatively noisy, which indicated the potential of this system to operate in unconstructed environment. This paper demonstrated that environmental information should be considered for operating wearable lower limb robotic devices, such as prosthetics and orthotics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Cohen, J. (2013) · doi:10.4324/9780203771587 · Cited by 25,373
Visual simultaneous localization and mapping: a survey
Fuentes-Pacheco, J., Ruiz-Ascencio, J., & Rendón-Mancha, J. M. (2015) · Artificial Intelligence Review · doi:10.1007/s10462-012-9365-8 · Cited by 883
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Self-citationIntention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Sit-to-stand and stand-to-sit transfer support for complete paraplegic patients with robot suit HAL
Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y. (2010) · Advanced Robotics · doi:10.1163/016918610x512622 · Cited by 269
Cited by
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Daily Locomotion Recognition and Prediction: A Kinematic Data-Based Machine Learning Approach
Figueiredo, J., Carvalho, S. P., Goncalve, D., Moreno, J. C., & Santos, C. P. (2020) · IEEE Access · doi:10.1109/access.2020.2971552 · Cited by 37
A strain gauge based locomotion mode recognition method using convolutional neural network
Feng, Y., Chen, W., & Wang, Q. (2019) · Advanced Robotics · doi:10.1080/01691864.2018.1563500 · Cited by 28
Whole body awareness for controlling a robotic transfemoral prosthesis
Parri, A., Martini, E., Geeroms, J., Flynn, L., Pasquini, G., Crea, S., Molino Lova, R., Lefeber, D., Kamnik, R., Munih, M., et al. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00025 · Cited by 29
“Recent advancements have implemented environment awareness controller by means of depth or infrared sensing (Zhang et al., 2011; Krausz et al., 2015; Liu et al., 2016) to detect different terrains; nevertheless, strong reliance on the sensor’s line of sight is one of the main limitations of such approach.”
Background
Metadata
- Authors
- Liu, M., Wang, D., & Huang, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-04
- Volume
- 24
- Issue
- 4
- Pages
- 434-443
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1967516228
- Cited by
- 145
- References
- 6
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of an Environment-Aware Locomotion Mode Recognition System for Powered Lower Limb Prostheses. https://app.cochat.ai/papers/10.1109/tnsre.2015.2420539
- The paper
- Liu, M., Wang, D., & Huang, H. (2016). Development of an Environment-Aware Locomotion Mode Recognition System for Powered Lower Limb Prostheses. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2015.2420539
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.