Transradial Amputee Gesture Classification Using an Optimal Number of sEMG Sensors: An Approach Using ICA Clustering
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Surface electromyography (sEMG)-based pattern recognition studies have been widely used to improve the classification accuracy of upper limb gestures. Information extracted from multiple sensors of the sEMG recording sites can be used as inputs to control powered upper limb prostheses. However, usage of multiple EMG sensors on the prosthetic hand is not practical and makes it difficult for amputees due to electrode shift/movement, and often amputees feel discomfort in wearing sEMG sensor array. Instead, using fewer numbers of sensors would greatly improve the controllability of prosthetic devices and it would add dexterity and flexibility in their operation. In this paper, we propose a novel myoelectric control technique for identification of various gestures using the minimum number of sensors based on independent component analysis (ICA) and Icasso clustering. The proposed method is a model-based approach where a combination of source separation and Icasso clustering was utilized to improve the classification performance of independent finger movements for transradial amputee subjects. Two sEMG sensor combinations were investigated based on the muscle morphology and Icasso clustering and compared to Sequential Forward Selection (SFS) and greedy search algorithm. The performance of the proposed method has been validated with five transradial amputees, which reports a higher classification accuracy ( > 95%). The outcome of this study encourages possible extension of the proposed approach to real time prosthetic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Validating the independent components of neuroimaging time series via clustering and visualization
Himberg, J., Hyvärinen, A., & Esposito, F. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.027 · Cited by 1,244 · cited 5×
“The mathematical basis of Icasso algorithm is explained in detail in [24].”
BackgroundMethodInfluentialUpper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111 · cited 1×
“For these people, the replacement of missing arm functionalities can be of a significant improvement to the quality of life [5]–[7].”
BackgroundFarina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992 · cited 1×
“The previous procedure based on ICA clustering can be used to fit a large number of EMG sensors unlike the currently used protocol to fit only single or 2 EMG sensors [34].”
MethodScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 1×
“Among these are an impractically large number of EMG sensors [10], variations in limb position [3], [11] and force variation [12], [13].”
BackgroundEuropean recommendations for surface electromyography results of the SENIAM project
Hermens, H. J. (1999) · Cited by 581
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495 · cited 1×
“Among these are an impractically large number of EMG sensors [10], variations in limb position [3], [11] and force variation [12], [13].”
BackgroundMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434 · cited 1×
“The benefits of a reduced subset of EMG sensors can be seen not only in the laboratory controlled experiments, but also in the real time clinical prostheses usage which will have an important role to enable the clinical implementation of PR systems [4], [15].”
BackgroundEvaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391 · cited 1×
“Furthermore, it has been shown that AR coefficients are computationally efficient and robust to displacements in electrode positions [7], [32]–[35].”
BackgroundLinear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365 · cited 1×
“I N recent years, myoelectric control based on surface electromyography (sEMG) has been the focus of the research on myoelectric prosthesis (MP) technology [1]–[4].”
BackgroundYe, J. (2005) · Cited by 353
Al-Timemy, A. H., Bugmann, G., Escudero, J., & Outram, N. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2249590 · Cited by 326 · cited 5×
“Furthermore, it has been shown that AR coefficients are computationally efficient and robust to displacements in electrode positions [7], [32]–[35].”
BackgroundMethodSelf-citationClassification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Hargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276 · cited 1×
“Furthermore, it has been shown that AR coefficients are computationally efficient and robust to displacements in electrode positions [7], [32]–[35].”
BackgroundProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2177662 · Cited by 251 · cited 1×
“Also, since the sEMG signals are estimated from the front and back side of the forearm muscles [18], [19], a combination of source separation and careful selection of muscle configuration would help to minimize the number of sEMG sensors.”
BackgroundKhushaba, R. N., Takruri, M., Miro, J. V., & Kodagoda, S. (2014) · Neural Networks · doi:10.1016/j.neunet.2014.03.010 · Cited by 204 · cited 1×
“Among these are an impractically large number of EMG sensors [10], variations in limb position [3], [11] and force variation [12], [13].”
BackgroundBionic prosthetic hands: A review of present technology and future aspirations
Clement, R. G. E., Bugler, K. E., & Oliver, C. W. (2011) · The Surgeon · doi:10.1016/j.surge.2011.06.001 · Cited by 189 · cited 14×
“network, k-Nearest Neighbors (kNN) and LDA [6].”
MethodInfluentialHuang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187 · cited 15×
“To test the statistical significance between the 2 EMG sensor combinations, an independent-samples Mann-Whitney (nonparametric test) test was applied to find differences in classification errors of the two sensor combination schemes (1, 3, 7, 9 and 2, 3, 7, 9), (1, 3, 7, 9 and SFS), and (1, 3, 7, 9 and Greedy search a…”
MethodInfluentialMyoelectric Control Development Toolbox
Chan, A. D. C., & Green, G. C. (2007) · CMBES Proceedings · Cited by 167
Measuring directional coupling between EEG sources
Gómez-Herrero, G., Atienza, M., Egiazarian, K., & Cantero, J. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.032 · Cited by 150 · cited 1×
“In the recent past, Icasso has been successfully used for various biomedical signal processing applications such as artefact removal [25], measuring directional coupling between electroencephalography (EEG) sources [26], brain functional connectivity [27], and repeatability measures on results of fMRI [28].”
MethodHe, J., Zhang, D., Sheng, X., Li, S., & Zhu, X. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2330356 · Cited by 134 · cited 1×
“Among these are an impractically large number of EMG sensors [10], variations in limb position [3], [11] and force variation [12], [13].”
BackgroundFine-grained mapping of mouse brain functional connectivity with resting-state fMRI
Mechling, A. E., Hübner, N. S., Lee, H., Hennig, J., von Elverfeldt, D., & Harsan, L. A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.078 · Cited by 92 · cited 1×
“In the recent past, Icasso has been successfully used for various biomedical signal processing applications such as artefact removal [25], measuring directional coupling between electroencephalography (EEG) sources [26], brain functional connectivity [27], and repeatability measures on results of fMRI [28].”
MethodElectromyogram Whitening for Improved Classification Accuracy in Upper Limb Prosthesis Control
Liu, L., Liu, P., Clancy, E. A., Scheme, E., & Englehart, K. B. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2243470 · Cited by 68 · cited 1×
“The approach consists of four sequential steps: 1) EMG signal conditioning and pre-processing; 2) EMG feature extraction; 3) EMG dimensionality reduction and 4) EMG pattern classification [8].”
MethodLiu, J., Li, X., Li, G., & Zhou, P. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.04.003 · Cited by 68
Geng, Y., Zhang, X., Zhang, Y., & Li, G. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-102 · Cited by 64 · cited 3×
“These features were chosen based on the fact that time domain features such as AR and RMS can achieve higher performance than that of other feature extraction methods such as Fourier transform and wavelet transform for the detection of various hand and finger movements with EMG signals [7], [17], [20].”
BackgroundMethodResponsiveness of the somatosensory system after nerve injury and amputation in the human hand
Schady, W., Braune, S., Watson, S., Torebjörk, H. E., & Schmidt, R. (1994) · Annals of Neurology · doi:10.1002/ana.410360114 · Cited by 55 · cited 1×
“This result shows that the subjects could control the muscles despite the central reorganization that takes place after amputation, in accordance to what is described for the somatosensory path [39], [40].”
ResultIdentification of Hand and Finger Movements Using Multi Run ICA of Surface Electromyogram
Naik, G. R., & Kumar, D. (2010) · Journal of Medical Systems · doi:10.1007/s10916-010-9548-2 · Cited by 50 · cited 2×
“One of the advantages of using ICA is that it decomposes the linearly mixed several muscle activities into its constituent ICs or motor units [20], [22].”
MethodSelf-citationAn independent component analysis-based approach on ballistocardiogram artifact removing
Briselli, E., Garreffa, G., Bianchi, L., Bianciardi, M., Macaluso, E., Abbafati, M., Marciani, M. G., & Maraviglia, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.01.008 · Cited by 48 · cited 1×
“In the recent past, Icasso has been successfully used for various biomedical signal processing applications such as artefact removal [25], measuring directional coupling between electroencephalography (EEG) sources [26], brain functional connectivity [27], and repeatability measures on results of fMRI [28].”
MethodDetermining delay created by multifunctional prosthesis controllers
Farrell, T. R. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0055 · Cited by 39 · cited 1×
“Also, since the sEMG signals are estimated from the front and back side of the forearm muscles [18], [19], a combination of source separation and careful selection of muscle configuration would help to minimize the number of sEMG sensors.”
BackgroundNaik, G. R., Arjunan, S. P., & Kumar, D. (2011) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-011-0066-4 · Cited by 34
Self-citationNaik, G. R., Baker, K. G., & Nguyen, H. T. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2340397 · Cited by 32 · cited 1×
“The aim of ICA is to find the unknown muscle component(s) into their motor unit action potential trains MUAPS/ICs, such that , where is called the mixing matrix (without any prior information) [20], [29].”
BackgroundSelf-citationNaik, G. R., & Kumar, D. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.515211 · Cited by 31 · cited 4×
“These features were chosen based on the fact that time domain features such as AR and RMS can achieve higher performance than that of other feature extraction methods such as Fourier transform and wavelet transform for the detection of various hand and finger movements with EMG signals [7], [17], [20].”
BackgroundMethodSelf-citationRemes, J. J., Starck, T., Nikkinen, J., Ollila, E., Beckmann, C. F., Tervonen, O. A., Kiviniemi, V. J., & Sílven, O. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.268 · Cited by 30 · cited 1×
“In the recent past, Icasso has been successfully used for various biomedical signal processing applications such as artefact removal [25], measuring directional coupling between electroencephalography (EEG) sources [26], brain functional connectivity [27], and repeatability measures on results of fMRI [28].”
MethodAli, A. H. (2013) · PEARL (University of Plymouth) · doi:10.24382/1817 · Cited by 5
Cited by
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Self-citationA Review on Electromyography Decoding and Pattern Recognition for Human-Machine Interaction
Simao, M., Mendes, N., Gibaru, O., & Neto, P. (2019) · IEEE Access · doi:10.1109/access.2019.2906584 · Cited by 234
“In order to extract significant information from sEMG raw data and successfully recognize the motions an amputee intends to do, a promising approach based on independent component analysis (ICA) is proposed in [58].”
BackgroundA review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2747899 · Cited by 57
“To compare our results with a study [11] focused on dynamic protocols, classes of motion, and HMI that are similar to the ones used in this study, the rest of the offline data analysis described in this article used the LDA classification algorithm.”
MethodInfluential
Metadata
- Authors
- Naik, G. R., Al-Timemy, A. H., & Nguyen, H. T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-08
- Volume
- 24
- Issue
- 8
- Pages
- 837-846
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2466222407
- Cited by
- 160
- References
- 35
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.