The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
LOPES II—Design and Evaluation of an Admittance Controlled Gait Training Robot With Shadow-Leg Approach
Open accessAbstract
Robotic gait training is gaining ground in rehabilitation. Room for improvement lies in reducing donning and doffing time, making training more task specific and facilitating active balance control, and by allowing movement in more degrees of freedom. Our goal was to design and evaluate a robot that incorporates these improvements. LOPES II uses an end-effector approach with parallel actuation and a minimum amount of clamps. LOPES II has eight powered degrees of freedom (hip flexion/extension, hip abduction/adduction, knee flexion/extension, pelvis forward/aft and pelvis mediolateral). All other degrees of freedom can be left free and pelvis frontal- and transversal rotation can be constrained. Furthermore arm swing is unhindered. The end-effector approach eliminates the need for exact alignment, which results in a donning time of 10-14 min for first-time training and 5-8 min for recurring training. LOPES II is admittance controlled, which allows for the control over the complete spectrum from low to high impedance. When the powered degrees of freedom are set to minimal impedance, walking in the device resembles free walking, which is an important requisite to allow task-specific training. We demonstrated that LOPES II can provide sufficient support to let severely affected patients walk and that we can provide selective support to impaired aspects of gait of mildly affected patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Multicenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652
Hornby, T. G., Campbell, D. D., Kahn, J. H., Demott, T., Moore, J. L., & Roth, H. R. (2008) · Stroke · doi:10.1161/strokeaha.107.504779 · Cited by 541
Cao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
Cited by
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Kapsalyamov, A., Hussain, S., Brown, N. A. T., Goecke, R., Hayat, M., & Jamwal, P. K. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105500 · Cited by 45
Furukawa, J.-I., & Morimoto, J. (2025) · npj Robotics · doi:10.1038/s44182-025-00033-4 · Cited by 3
Metadata
- Authors
- Meuleman, J., van Asseldonk, E., van Oort, G., Rietman, H., & van der Kooij, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-03
- Volume
- 24
- Issue
- 3
- Pages
- 352-363
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2290386444
- Cited by
- 170
- References
- 4
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: LOPES II—Design and Evaluation of an Admittance Controlled Gait Training Robot With Shadow-Leg Approach. https://app.cochat.ai/papers/10.1109/tnsre.2015.2511448
- The paper
- Meuleman, J., van Asseldonk, E., van Oort, G., Rietman, H., & van der Kooij, H. (2016). LOPES II—Design and Evaluation of an Admittance Controlled Gait Training Robot With Shadow-Leg Approach. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2015.2511448
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.