Cortical Brain–Computer Interface for Closed-Loop Deep Brain Stimulation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Essential tremor is the most common neurological movement disorder. This progressive disease causes uncontrollable rhythmic motions-most often affecting the patient'sdominant upper extremity-thatoccur during volitional movement and make it difficult for the patient to perform everyday tasks. Medication may also become ineffective as the disorder progresses. For many patients, deep brain stimulation (DBS) of the thalamus is an effective means of treating this condition when medication fails. In current use, however, clinicians set the patient's stimulator to apply stimulation at all times-whether it is needed or not. This practice leads to excess power use, and more rapid depletion of batteries that require surgical replacement. In this paper, for the first time, neural sensing of movement (using chronically implanted cortical electrodes) is used to enable or disable stimulation for tremor. Therapeutic stimulation is delivered onlywhen the patient is actively using their effected limb, thereby reducing the total stimulation applied, and potentially extending the lifetime of surgically implanted batteries. This paper, which involves both implanted and external subsystems, paves the way for fully-implanted closed-loop DBS in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Louis, E. D., & Ferreira, J. J. (2010) · Movement Disorders · doi:10.1002/mds.22838 · Cited by 906
Louis, E. D., Ottman, R., & Allen Hauser, W. (1998) · Movement Disorders · doi:10.1002/mds.870130105 · Cited by 424 · cited 1×
“SSENTIAL Tremor (ET) is the most common neurological movement disorder [1] and it has a dramatic”
BackgroundThe safety and efficacy of thalamic deep brain stimulation in essential tremor: 10 years and beyond
Baizabal-Carvallo, J. F., Kagnoff, M. N., Jimenez-Shahed, J., Fekete, R., & Jankovic, J. (2014) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2013-304943 · Cited by 181 · cited 2×
“thalamus is often used to give otherwise unresponsive patients control of their limb and freedom from disabling tremor symptoms [4], [5].”
BackgroundHerron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L. (2017) · Journal of Neurosurgery · doi:10.3171/2016.8.jns16536 · Cited by 139 · cited 8×
“resulted in both power savings and suppression of tremor [9].”
BackgroundMethodInfluentialSelf-citationOn-Demand Control System for Deep Brain Stimulation for Treatment of Intention Tremor
Yamamoto, T., Katayama, Y., Ushiba, J., Yoshino, H., Obuchi, T., Kobayashi, K., Oshima, H., & Fukaya, C. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2012.00521.x · Cited by 90 · cited 1×
“Prior applications of closed-loop DBS for ET in human subjects have exclusively used wearable inertial sensors [9], or electromyography (EMG) to provide feedback for closed-loop DBS experiments [9], [10].”
Cited by
Adaptive deep brain stimulation for Parkinson’s disease using motor cortex sensing
Swann, N. C., de Hemptinne, C., Thompson, M. C., Miocinovic, S., Miller, A. M., Gilron, R., Ostrem, J. L., Chizeck, H. J., & Starr, P. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aabc9b · Cited by 389
Self-citationSchmidt, R., Herrojo Ruiz, M., Kilavik, B. E., Lundqvist, M., Starr, P. A., & Aron, A. R. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.1163-19.2019 · Cited by 338
Homecare robotic systems for healthcare 4.0: visions and enabling technologies
Yang, G., Pang, Z., Jamal Deen, M., Dong, M., Zhang, Y.-T., Lovell, N., & Rahmani, A. M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2990529 · Cited by 213
Tan, H., Debarros, J., He, S., Pogosyan, A., Aziz, T. Z., Huang, Y., Wang, S., Timmermann, L., Visser-Vandewalle, V., Pedrosa, D. J., et al. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.02.011 · Cited by 83
“A recent single case study 93 has shown that this approach can reduce tremor duri ng writing and spiral drawing [16].”
BackgroundMethodBelkacem, A. N., Jamil, N., Khalid, S., & Alnajjar, F. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1085173 · Cited by 80
Metadata
- Authors
- Herron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-11
- Volume
- 25
- Issue
- 11
- Pages
- 2180-2187
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2560692261
- Cited by
- 85
- References
- 5
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cortical Brain–Computer Interface for Closed-Loop Deep Brain Stimulation. https://app.cochat.ai/papers/10.1109/tnsre.2017.2705661
- The paper
- Herron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L. (2017). Cortical Brain–Computer Interface for Closed-Loop Deep Brain Stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2017.2705661
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.