CoChat

Cortical Brain–Computer Interface for Closed-Loop Deep Brain Stimulation

Open access
Herron, Jeffrey A., Thompson, Margaret C., Brown, Timothy, Chizeck, Howard Jay, Ojemann, Jeffrey G., Ko, Andrew L. · 2017 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 85

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Essential tremor is the most common neurological movement disorder. This progressive disease causes uncontrollable rhythmic motions-most often affecting the patient'sdominant upper extremity-thatoccur during volitional movement and make it difficult for the patient to perform everyday tasks. Medication may also become ineffective as the disorder progresses. For many patients, deep brain stimulation (DBS) of the thalamus is an effective means of treating this condition when medication fails. In current use, however, clinicians set the patient's stimulator to apply stimulation at all times-whether it is needed or not. This practice leads to excess power use, and more rapid depletion of batteries that require surgical replacement. In this paper, for the first time, neural sensing of movement (using chronically implanted cortical electrodes) is used to enable or disable stimulation for tremor. Therapeutic stimulation is delivered onlywhen the patient is actively using their effected limb, thereby reducing the total stimulation applied, and potentially extending the lifetime of surgically implanted batteries. This paper, which involves both implanted and external subsystems, paves the way for fully-implanted closed-loop DBS in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2017.2705661

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 85

Metadata

Authors
Herron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2017-11
Volume
25
Issue
11
Pages
2180-2187
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2560692261
Cited by
85
References
5
FWCI
6.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cortical Brain–Computer Interface for Closed-Loop Deep Brain Stimulation. https://app.cochat.ai/papers/10.1109/tnsre.2017.2705661
The paper
Herron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L. (2017). Cortical Brain–Computer Interface for Closed-Loop Deep Brain Stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2017.2705661

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.