The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
The Role of Haptics in Medical Training Simulators: A Survey of the State of the Art
Abstract
This review paper discusses the role of haptics within virtual medical training applications, particularly, where it can be used to aid a practitioner to learn and practice a task. The review summarizes aspects to be considered in the deployment of haptics technologies in medical training. First, both force/torque and tactile feedback hardware solutions that are currently produced commercially and in academia are reviewed, followed by the available haptics-related software and then an in-depth analysis of medical training simulations that include haptic feedback. The review is summarized with scrutiny of emerging technologies and discusses future directions in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Burdea, G., & Coiffet, P. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322955950 · Cited by 2,315
Sutherland, I. E. (1965) · Cited by 1,073
Gallagher, A. G., Ritter, E. M., Champion, H., Higgins, G., Fried, M. P., Moses, G., Smith, C. D., & Satava, R. M. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000151982.85062.80 · Cited by 1,051
Force and Touch Feedback for Virtual Reality
Burdea, G. (1996) · Cited by 1,019
Physically Based Deformable Models in Computer Graphics
Nealen, A., Müller, M., Keiser, R., Boxerman, E., & Carlson, M. (2006) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2006.01000.x · Cited by 759
van der Meijden, O. A. J., & Schijven, M. P. (2009) · Surgical Endoscopy · doi:10.1007/s00464-008-0298-x · Cited by 541
Haptic rendering: introductory concepts
Salisbury, K., Conti, F., & Barbagli, F. (2004) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2004.1274058 · Cited by 463
Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis
Tholey, G., Desai, J. P., & Castellanos, A. E. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000149301.60553.1e · Cited by 330
The surgical learning curve for laparoscopic radical prostatectomy: a retrospective cohort study
Vickers, A. J., Savage, C. J., Hruza, M., Tuerk, I., Koenig, P., Martínez-Piñeiro, L., Janetschek, G., & Guillonneau, B. (2009) · The Lancet Oncology · doi:10.1016/s1470-2045(09)70079-8 · Cited by 289
A Survey of Surgical Simulation: Applications, Technology, and Education
Liu, A., Tendick, F., Cleary, K., & Kaufmann, C. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322955905 · Cited by 279
Human Grasp Choice and Robotic Grasp Analysis
Cutkosky, M. R., & Howe, R. D. (1990) · Dextrous Robot Hands · doi:10.1007/978-1-4613-8974-3_1 · Cited by 271
Taffinder, N., Sutton, C., Fishwick, R. J., C, M. I., & Darzi, A. (1998) · Studies in Health Technology and Informatics · doi:10.3233/978-1-60750-894-6-124 · Cited by 263
Cohen, J., Cohen, S. A., Vora, K. C., Xue, X., Burdick, J. S., Bank, S., Bini, E. J., Bodenheimer, H., Cerulli, M., Gerdes, H., et al. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.11.062 · Cited by 224
The Role of Haptic Feedback in Laparoscopic Simulation Training
Panait, L., Akkary, E., Bell, R. L., Roberts, K. E., Dudrick, S. J., & Duffy, A. J. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2009.04.018 · Cited by 222
Haptic Feedback Enhances Force Skill Learning
Morris, D., Tan, H., Barbagli, F., Chang, T., & Salisbury, K. (2007) · Second Joint EuroHaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems (WHC'07) · doi:10.1109/whc.2007.65 · Cited by 208
Vibration feedback models for virtual environments
Okamura, A. M., Dennerlein, J. T., & Howe, R. D. (2002) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.677050 · Cited by 207
Surgical Skills Training and Simulation
Tsuda, S., Scott, D., Doyle, J., & Jones, D. B. (2009) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2008.12.003 · Cited by 206
Errors in clinical reasoning: causes and remedial strategies
Scott, I. A. (2009) · BMJ · doi:10.1136/bmj.b1860 · Cited by 146
Virtual reality-based training for the diagnosis of prostate cancer
Burdea, G., Patounakis, G., Popescu, V., & Weiss, R. E. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.790503 · Cited by 135
An integrated tactile/shear feedback array for stimulation of finger mechanoreceptor
Caldwell, D. G., Tsagarakis, N. G., & Giesler, C. (2003) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1999.769991 · Cited by 115
Soft tissue modelling for applications in virtual surgery and surgical robotics
Famaey, N., & Sloten, J. V. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802020412 · Cited by 115
Computer Graphics And Virtual Environments: From Realism to Real-Time
Slater, M., Steed, A. J., & Chrysanthou, Y. (2001) · UCL Discovery (University College London) · Cited by 109
Thao, D., Annaswamy, T. M., & Srinivasan, M. A. (2001) · Studies in health technology and informatics · doi:10.3233/978-1-60750-925-7-97 · Cited by 99
Spring: A General Framework for Collaborative, Real-time Surgical Simulation
Montgomery, K. N., Bruyns, C. D., Brown, J. M., II, Sorkin, S., Mazzella, F., Thonier, G., Arnaud, T., Benjamin, L., & Menon, A. (2002) · Studies in health technology and informatics · doi:10.3233/978-1-60750-929-5-296 · Cited by 88
The United States Military's Thigh Trauma Simulator
Reinig, K. D., Lee, C. R., Rubinstein, D., Bagur, M., & Spitzer, V. M. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000194678.10130.ff · Cited by 87
A Survey of Computer-Based Deformable Models
Moore, P., & Molloy, D. (2007) · International Machine Vision and Image Processing Conference (IMVIP) · doi:10.1109/imvip.2007.31 · Cited by 81
Pneumatic balloon actuators for tactile feedback in robotic surgery
Culjat, M. O., King, C., Franco, M. L., Bisley, J. W., Grundfest, W. S., & Dutson, E. (2008) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439910810893617 · Cited by 74
A prototype haptic suturing simulator.
Webster, R. W., Zimmerman, D. I., Mohler, B. J., Melkonian, M. G., & Haluck, R. S. (2001) · PubMed · Cited by 60
Principles and Applications of Computer Graphics in Medicine
Vidal, F. P., Bello, F., Brodlie, K., John, N. W., Gould, D., Phillips, R., & Avis, N. J. (2006) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2006.00822.x · Cited by 57
Self-citationMechano thermo and proprioceptor feedback for integrated haptic feedback
Caldwell, D. G., Tsagarakis, N. G., & Wardle, A. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1997.619335 · Cited by 53
Survey on Communication through Touch
Pasquero, J. (2006) · Cited by 50
A Study on the Perception of Haptics in Surgical Simulation
Batteau, L. M., Liu, A., Maintz, J. B. A., Bhasin, Y., & Bowyer, M. W. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-25968-8_21 · Cited by 32
de Pascale, M., & Prattichizzo, D. (2007) · IEEE Robotics & Automation Magazine · doi:10.1109/m-ra.2007.905747 · Cited by 32
Sherman, K., Ward, J. W., Wills, D. P. M., Sherman, V. J., & Mohsen, A. (2001) · PubMed · Cited by 31
Haptic palpation of head and neck cancer patients--implication for education and telemedicine.
Stalfors, J., Kling-Petersen, T., Rydmark, M., & Westin, T. (2001) · PubMed · Cited by 22
MHaptic : a Haptic Manipulation Library for Generic Virtual Environments
Ott, R., Perrot, V. D., Thalmann, D., & Vexo, F. (2007) · International Conference on Cyberworlds (CW) · doi:10.1109/cw.2007.54 · Cited by 20
Smart tutor: a pilot study of a novel adaptive simulation environment.
Pham, T. H., Roland, L., Benson, K., et al. (2005) · PubMed · Cited by 14
On an Analysis of Pass Play in a Virtual Ball Game
Osato, K., Yonekura, T., Kawano, Y., & Hanawa, D. (2007) · International Conference on Cyberworlds (CW) · doi:10.1109/cw.2007.46 · Cited by 13
HERMES: An Angioplasty Surgery Simulator
Raspolli, M., Avizzano, C. A., Facenza, G., & Bergamasco, M. (2005) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2005.73 · Cited by 8
Cited by
Virtual and augmented reality applications in medicine: analysis of the scientific literature
Yeung, A. W. K., Tosevska, A., Klager, E., Eibensteiner, F., Laxar, D., Stoyanov, J., Glisic, M., Zeiner, S., Kulnik, S. T., Crutzen, R., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/25499 · Cited by 428
Robotic tactile perception of object properties: A review
Luo, S., Bimbo, J., Dahiya, R., & Liu, H. (2017) · Mechatronics · doi:10.1016/j.mechatronics.2017.11.002 · Cited by 425
Technology‐mediated learning theory
Bower, M. (2019) · British Journal of Educational Technology · doi:10.1111/bjet.12771 · Cited by 321
Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review
Rafii-Tari, H., Payne, C. J., & Yang, G.-Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0946-8 · Cited by 288
Panariello, D., Caporaso, T., Grazioso, S., Di Gironimo, G., Lanzotti, A., Knopp, S., Pelliccia, L., Lorenz, M., & Klimant, P. (2019) · 2019 Third IEEE International Conference on Robotic Computing (IRC) · doi:10.1109/irc.2019.00094 · Cited by 24
Metadata
- Authors
- Coles, T. R., Meglan, D., & John, N. W.
- Venue
- IEEE Transactions on Haptics
- Published
- 2011-01
- Volume
- 4
- Issue
- 1
- Pages
- 51-66
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2101535012
- Cited by
- 484
- References
- 39
- FWCI
- 25.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.