HyVE—Hybrid Vibro-Electrotactile Stimulation—Is an Efficient Approach to Multi-Channel Sensory Feedback
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
An important reason for the abandonment of commercial actuated hand prostheses by the users is the lack of sensory feedback. Wearable afferent interfaces capable of providing electro- or vibro-tactile stimulation have high potential to restore the missing tactile and/or proprioceptive information to the user. By definition, these devices can elicit single modality (i.e., either vibrotactile or electrotactile) substitute sensations. In a recent research we have presented a novel approach comprising hybrid vibro-electrotactile (HyVE) combined stimulation, in order to provide multimodal sensory feedback. An important advantage of this approach is in the size of the design: the HyVE interface is much more compact than two separated single-modality interfaces, since electro- and vibro-tactile stimulators are placed one on top of the other. The HyVE approach has been previously tested in healthy subjects and has shown to provide a range of hybrid stimuli that could be properly discriminated. However, this approach has never been assessed as a method to provide multi-channel stimuli, i.e., stimuli from a variety of stimulators, mapping information from a multitude of sensors on a prosthesis. In this study, the ability of ten healthy subjects to discriminate stimuli and patterns of stimuli from four different five-channel interfaces applied on their forearms was evaluated. We showed that multiple HyVE units could be used to provide multi-channel sensory information with equivalent performance (∼95 percent for single stimuli and ∼80 percent for pattern) to single modality interfaces (vibro- or electro-tactile) larger in size and with better performance than vibrotactile interfaces (i.e., 73 percent for single stimuli and 69 percent for pattern) with the same size. These results are promising in relation to the current availability of multi-functional prostheses with multiple sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 1×
“Some of these methods made use o f invasive surgical procedures and relied on direct e lectrical stimulation of sensory neural structures which are physiologically involved in the task, using implant ble electrodes [9], [10].”
MethodClosed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 1×
“Vibrotactile and electrotactile devices were investigated separately in a number of studies in the past [17], [18], [19], [20], [21], [22], [23], [24],”
BackgroundVibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150 · cited 4×
“used single-modality multiple stimulators and only in few cases they compared the differences between the mod alities [19], [31].”
BackgroundMethodInfluentialRiso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Cited by
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
Rupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
Multichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
Self-citation
Metadata
- Authors
- DrAlonzo, M., Dosen, S., Cipriani, C., & Farina, D.
- Venue
- IEEE Transactions on Haptics
- Published
- 2014-04
- Volume
- 7
- Issue
- 2
- Pages
- 181-190
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2329377356
- Cited by
- 50
- References
- 7
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HyVE—Hybrid Vibro-Electrotactile Stimulation—Is an Efficient Approach to Multi-Channel Sensory Feedback. https://app.cochat.ai/papers/10.1109/toh.2013.52
- The paper
- DrAlonzo, M., Dosen, S., Cipriani, C., & Farina, D. (2014). HyVE—Hybrid Vibro-Electrotactile Stimulation—Is an Efficient Approach to Multi-Channel Sensory Feedback. IEEE Transactions on Haptics. https://doi.org/10.1109/toh.2013.52
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.