Method for Providing Electrovibration with Uniform Intensity
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Electrovibration is a type of surface haptics that can modulate lateral forces acting between a fingertip and a touch surface. Electrovibration is fast, consumes little power, and does not involve the use of any mechanical actuators. However, it suffers from problems such as nonuniform perceived intensity due to varying environmental impedances, as well as possible electric shock, which have to be solved for commercialization. In this paper, a current feedback method is proposed to provide uniform intensity of electrovibration, regardless of the varying environmental impedances. The proposed method can also prevent electric shock. To show the effectiveness of the proposed method, a hardware prototype was developed and a user study was conducted. The user study result shows that the proposed current control method can provide significantly more uniform perceived intensity of electrovibration as compared with the conventional voltage control method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429
Squeeze film effect for the design of an ultrasonic tactile plate
Biet, M., Giraud, F., & Lemaire-Semail, B. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.596 · Cited by 207 · cited 2×
“Surface haptic devices [1], [2], [3], [4], [5], [6], [7] focusing on friction force modulation between a fingertip and a surface, are one of the alternatives to the abovementioned vibration motors.”
BackgroundMethod
Cited by
Haptic display for virtual reality: progress and challenges
WANG, D., GUO, Y., LIU, S., ZHANG, Y., XU, W., & XIAO, J. (2019) · Virtual Reality & Intelligent Hardware · doi:10.3724/sp.j.2096-5796.2019.0008 · Cited by 262
Effect of Waveform on Tactile Perception by Electrovibration Displayed on Touch Screens
Vardar, Y., Guclu, B., & Basdogan, C. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2704603 · Cited by 130
Mechanical Vibration Influences the Perception of Electrovibration
Ryu, S., Pyo, D., Lim, S.-C., & Kwon, D.-S. (2018) · Scientific Reports · doi:10.1038/s41598-018-22865-x · Cited by 31
Audio-Tactile Skinny Buttons for Touch User Interfaces
Van Duong, Q., Nguyen, V. P., Luu, A. T., & Choi, S. T. (2019) · Scientific Reports · doi:10.1038/s41598-019-49640-w · Cited by 21
Metadata
- Authors
- Kim, H., Kang, J., Kim, K.-D., Lim, K.-M., & Ryu, J.
- Venue
- IEEE Transactions on Haptics
- Published
- 2015-10-01
- Volume
- 8
- Issue
- 4
- Pages
- 492-496
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2218056801
- Cited by
- 37
- References
- 3
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method for Providing Electrovibration with Uniform Intensity. https://app.cochat.ai/papers/10.1109/toh.2015.2476810
- The paper
- Kim, H., Kang, J., Kim, K.-D., Lim, K.-M., & Ryu, J. (2015). Method for Providing Electrovibration with Uniform Intensity. IEEE Transactions on Haptics. https://doi.org/10.1109/toh.2015.2476810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.