Online Stability in Human-Robot Cooperation with Admittance Control
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In the design of a compliant admittance controller for physical human-robot interaction, it is necessary to ensure stable and effective cooperation. The stability of the admittance controller is mainly threatened by a stiff environment. Many methods that guarantee stability in arbitrary environments, impose conservative control gains that limit the effectiveness of the cooperation. Inspired by previous work in frequency domain stability observers, a method is proposed in this paper to detect unstable behavior and stabilize the robot with online adaptation of the admittance control gains. The introduced instability index is based on frequency domain analysis, which very quickly detects unstable behavior by monitoring high frequency oscillation in the force signal. To treat the instability, an adaptation scheme of the admittance parameters is proposed, that relaxes conservative gains and improves the cooperation by considering the effect of variable admittance on the operators' effort. We investigate two human-robot co-manipulation tasks; cooperation within a zero stiffness environment and cooperation in contact with a stiff double-wall virtual environment. The proposed methods are validated experimentally with a number of subjects in cooperation with an LWR manipulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929 · cited 1×
“The admittance scheme [1] is widely used for compliance control of robotic manipulators.”
MethodThe central nervous system stabilizes unstable dynamics by learning optimal impedance
Burdet, E., Osu, R., Franklin, D. W., Milner, T. E., & Kawato, M. (2001) · Nature · doi:10.1038/35106566 · Cited by 1,097
Time-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
Robust control of dynamically interacting systems
COLGATE, J. E., & HOGAN, N. (1988) · International Journal of Control · doi:10.1080/00207178808906161 · Cited by 589
Human hand impedance characteristics during maintained posture
Tsuji, T., Morasso, P. G., Goto, K., & Ito, K. (1995) · Biological Cybernetics · doi:10.1007/bf00199890 · Cited by 469 · cited 1×
“These values correspond to the average stiffness levels of a human arm [19], [20].”
BackgroundComplementary Stability and Loop Shaping for Improved Human–Robot Interaction
Buerger, S. P., & Hogan, N. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.892229 · Cited by 269 · cited 2×
“generalized to multiple degree of freedom manipulators [3],”
BackgroundEffects of voluntary force generation on the elastic components of endpoint stiffness
Perreault, E., Kirsch, R., & Crago, P. (2001) · Experimental Brain Research · doi:10.1007/s002210100880 · Cited by 158 · cited 1×
“relatively low and below 2 Hz [16], [17].”
BackgroundCartesian impedance control of redundant manipulators for human-robot co-manipulation
Ficuciello, F., Romano, A., Villani, L., & Siciliano, B. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6942847 · Cited by 93 · cited 1×
“Instability can occur when the admittance controller tries to impose a desired dynamic behavior to the robot that is significantly different from the manipulator’s inherent dynamics [13], or when the robot is in contact with a very stiff environment [14].”
BackgroundInvestigation of human-robot interaction stability using Lyapunov theory
Duchaine, V., & Gosselin, C. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543531 · Cited by 77 · cited 3×
“ducted in [6], and the critical damping for the admittance controller is calculated using the Lyapunov theory.”
MethodFuzzy learning variable admittance control for human-robot cooperation
Dimeas, F., & Aspragathos, N. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6943240 · Cited by 77 · cited 1×
“cooperating with an LWR robot from [18].”
Self-citation
Cited by
Progress and prospects of the human–robot collaboration
Ajoudani, A., Zanchettin, A. M., Ivaldi, S., Albu-Schäffer, A., Kosuge, K., & Khatib, O. (2018) · Autonomous Robots · doi:10.1007/s10514-017-9677-2 · Cited by 832
Physical Human–Robot Interaction of a Robotic Exoskeleton By Admittance Control
Li, Z., Huang, B., Ye, Z., Deng, M., & Yang, C. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2821649 · Cited by 306
Younis, H. A., Ruhaiyem, N. I. R., Badr, A. A., Abdul-Hassan, A. K., Alfadli, I. M., Binjumah, W. M., Altuwaijri, E. A., & Nasser, M. (2023) · Processes · doi:10.3390/pr11051488 · Cited by 21
Towards Explainable and Trustworthy Autonomous Physical Systems
Omeiza, D., Anjomshoae, S., Kollnig, K., Camburu, O.-M., Främling, K., & Kunze, L. (2021) · Extended Abstracts of the 2021 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411763.3441338 · Cited by 2
“It is important to investigate ways to enable these autonomous physical systems to communicate with humans and other systems, provide reasons behind their actions and also communicate unstable conditions or adversarial attacks [4, 8, 9].”
Background
Metadata
- Authors
- Dimeas, F., & Aspragathos, N.
- Venue
- IEEE Transactions on Haptics
- Published
- 2016-04-01
- Volume
- 9
- Issue
- 2
- Pages
- 267-278
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2438255111
- Cited by
- 207
- References
- 15
- FWCI
- 18.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.